JP MORGAN CHASE BANK, NA | H02 | C | 04/26/2024 | 5 YEAR 3/21 -- ANNUAL 11/23 -- OTIS W/ KONE SERVICE -PERFORMED SIX MONTH INSPECTION TO ONLY VERIFY CODE COMPLIANT MCP, LOGS, FIREFIGHTERS' EMERGENCY OPERATION AND ELEVATOR TWO-WAY COMMUNICATION- OTIS SPEAR IS INTERMITTENTLY CLIPPING PICK UP ROLLER ON 2ND FLOOR SETTING ROPE GRIPPER MECHANIC TO DIAGNOSE. (Receipt #2057559) | PAULM | PAULM | | H02 | C | 8065703 |
JP MORGAN CHASE BANK, NA | H03 | C | 12/05/2023 | 5 YEAR 3/21 -- ANNUAL 11/23 -- OTIS W/ KONE SERVICE -- / PERFORMED RE-INSPECTION FOR PREVIOUS ITEMS LISTED AT PERIODIC INSPECTION. ALL ITEMS HAVE BEEN ADDRESSED. PERMIT TO OPERATE HAS BEEN EMAILED. (Receipt #2013503) | DUSTINS | DUSTINS | | H03 | C | 7936249 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/25/2023 | 5YR -- 3/2021 -- CAT1 -- 8/2022 -- OTIS W/ KONE SERVICE. REQUIRED ANNUAL CATEGORY 1 TESTING IS PAST DUE, NEEDS TO BE PERFORMED WITHIN 10 DAY TO AVOID SHUTDOWN............ ALSO, EMERGENCY BRAKE ROPE GRIPPER DOES NOT SELF RESET WHEN POWER IS DISCONNECTED. CAR DOOR RESTRICTION COMPONENTS NEED TO BE ADDED ON FASCIA BETWEEN FLOORS. TOP FLOOR HOISTWAY DOOR ECCENTRICS NEED TO BE ADJUSTED TO PREVENT SIDE TO SIDE MOVEMENT NOT TO EXCEEDING 1 INCH MEASURED AT SILL. ELEVATOR PIT NEEDS CLEANED. BUILDING PERSONNEL TO MAINTAIN WRITTEN ELEVATOR MONTHLY FIRE FIGHTERS SERVICE TESTING AND ELEVATOR QUARTERLY EMERGENCY PHONE TESTING LOGS PER STATE OF COLORADO CONVEYANCE REGULATIONS. (Copy and paste link for required State of Colorado Test Forms - https://ops.colorado.gov/sites/ops/files/2020-02/2020_monthly_fire_service_test_log_fillable.pdf ).............. THESE ITEMS NEED TO BE COMPLETED WITHIN 60 DAY TO PREVENT RED TAG NOTICE AND SHUTDOWN. (Receipt #2002169) | ROBERTV | ROBERTV | | H01 | C | 7899874 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/27/2023 | H02 -- 5 YEAR 3/21 -- ANNUAL 8/22 -- OTIS W/ KONE SERVICE -- SEE NOTES FOR ACCESS -- / | DUSTINS | DUSTINS | | H02 | C | 7728506 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/20/2022 | 5YR 03/2021 -- ANNUAL 08/2022 -- OTIS WITH KONE SERVICE --/ SEE NOTES FOR ACCESS --/ PROVIDE 2022 MONTHLY FIRE EMERGENCY AND QUARTERLY EMERGENCY TWO WAY COMMUNICATION LOGS --/ FIRE EXTINGUISHER IS EXPIRED IN THE MACHINE ROOM (Receipt #1908471) | MIKEM | MIKEM | | H01 | C | 7556443 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/28/2022 | HO2-- 5YR 03/2021-- OTIS WITH KONE SERVICE-- SEE NOTES FOR ACCESS--/ ANNUAL CATEGORY 1 TRACTION SAFETY TESTS ARE PAST DUE--/ FIRE EXTINGUISHER INSIDE THE MACHINE ROOM HAS EXPIRED -- cat1 8/2022 | MIKEM | MIKEM | | H02 | C | 7356173 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/18/2021 | 5 YEAR 3/2021 -- OTIS W/ KONE SERVICE -- / CAR FAULTED OUT DURING INSPECTION / EMERGENCY PHONE NONFUNCTIONAL / ELEVATOR DOES NOT TRAVEL TO BASEMENT LEVEL ON PHASE II / MACHINE ROOM FIRE EXTINGUISHER EXPIRED (Receipt #1815377) | RANDYB | RANDYB | | H01 | C | 7144257 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/19/2021 | H02 -- 5YR -- 3/21 -- OTIS W/ KONE. ELEVATOR COUNTERWEIGHT RUNBY HAS BEEN ADDRESSED | ROBERTV | ROBERTV | | H02 | C | 6938528 |
JP MORGAN CHASE BANK, NA | H06 | C | 03/11/2021 | WITNESSED TRACTION SAFETY INSPECTION AND TESTING W/ KONE - COUNTERWEIGHT RUNBY NEEDS TO BE DECREASED TO 4" FOR THIS PARTICULAR INSTALLATION TO ENSURE THE SAFETY OF ELEVATOR PERSONNEL, THE RIDING PUBLIC, AND THE EQUIPMENT......... 60 DAYS TO ADDRESS, REST OK. (11 HOURS TOTAL TIME) (Receipt #1756408) | ROBERTV | ROBERTV | | H06 | C | 6897217 |
JP MORGAN CHASE BANK, NA | HE16 | C | 12/17/2020 | ELEVATOR PHONE IS WORKING | ROBERTV | ROBERTV | | HE16 | C | 6811162 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/28/2020 | 5YR -- 2/16 -- CAT1 -- 10/20 -- OTIS W/ KONE SERVICE. ELEVATOR EMERGENCY PHONE NOT WORKING. NEED UP TO DATE FIRE SERVICE OPERATION TESTING LOGS IN MCP. NEED QUARTERLY EMERGENCY PHONE TESTING LOG ON SITE. FOLLOW UP SCHEDULED FOR 60 DAYS. WITNESS TEST DUE 2/2021 (Receipt #1725219) | ROBERTV | ROBERTV | | H01 | C | 6756731 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/27/2020 | 5YR 2/16--ANNUAL 8/19--OTIS W/ KONE SERVICE--HO2 | CALE | CALE | | H02 | C | 6552645 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/29/2019 | 5Y--2--16--OTIS --KONE SERVICEANNUAL 8--19--ELIGHTS AND ALARM INOP (Receipt #1640652) | JOHNW | JOHNW | | H01 | C | 6382575 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/10/2019 | 5YR -- 2/16 -- OTIS W/ KONE DIAL LOCKBOX. REQUIRED ANNUAL CATEGORY 1 TESTING IS PAST DUE, LAST PERFORMED 12/2017. EMERGENCY LIGHT AND ALARM BELL STILL NOT WORKING ON BATTERY POWER........... 30 DAYS TO ADDRESS THESE ITEMS. (Category 1 Testing performed 8/1/2019) | ROBERTV | ROBERTV | | H02 | C | 6161718 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/18/2018 | 5YR -- 2/16 -- ANNUAL 12/17 -- OTIS W/ KONE SERVICE. EMERGENCY LIGHT AND ALARM BELL NOT WORKING ON BATTERY POWER. (RBD NOTE: LOCKBOX OUTSIDE DOOR ON NORTH END OF BUILDING TOP BLACK LOCKBOX COMBO LETTERS ARE "IN NOTES") (Receipt #1548563) | ROBERTV | ROBERTV | | H01 | C | 5998219 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/27/2018 | 5YR --2--16--OTIS --ANNUAL 12--17--KONE SERVICE --LOCKBOX OUTSIDE DOOR ON NORTH END OF BUILDING TOP BLACK LOCKBOX COMBO LETTERS IN NOTES | JOHNW | JOHNW | | H02 | C | 5829095 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/20/2017 | 5YR -- 2/16 -- OTIS W/ KONE SERVICE. REQUIRED ANNUAL CATEGORY 1 SAFETY TESTING STILL HAS NOT BEEN PERFORMED, 30 DAYS TO ADDRESS. 2ND FLOOR HALL CALL STATION IS LOOSE ON WALL. (Receipt #1460762) | ROBERTV | ROBERTV | | H01 | C | 5662070 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/07/2017 | 5YR -- 2/16 -- OTIS W/ KONE LOCKBOX. REQUIRED ANNUAL CATEGORY 1 TEST DUE, PREVIOUS ITEMS HAVE BEEN ADDRESSED. | ROBERTV | ROBERTV | | H02 | C | 5467284 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/28/2016 | 5 YEAR 2/16 OTIS, KONE SERVICE. CAR DOOR RESTRICTOR BAR IS MISSING, EMERGENCY LIGHTS AND BELL ARE NOT WORKING, SUSPENSION ROPES AT TOP FLOOR EXCEED ALLOWABLE VALLEY WIRE BREAKS PER LAY (ALL ROPES WILL NEED TO BE REPLACED). NEED COMPLETE MAINTENANCE CONTROL PROGRAM ON SITE (Receipt #1376794) | ERIC | ERIC | | H01 | C | 5330274 |
JP MORGAN CHASE BANK, NA | HE16 | C | 08/29/2016 | ITEMS AS LISTED ON INSPECTION DATED 2/11/2016 HAVE YET TO BE REPAIRED/REPLACED. REPAIRS/REPLACEMENT MUST BE COMPLETED BY COMPLIANCE DATE TO AVOID SERVICE INTERRUPTION. --------- ITEMS AS PREVIOUSLY LISTED: CAB DOOR RESTRICTOR BAR IS MISSING, EMERGENCY LIGHTS AND BELL ARE NOT WORKING, SUSPENSION ROPES AT TOP FLOOR EXCEED ALLOWABLE VALLEY WIRE BREAKS PER LAY (ALL ROPES WILL NEED TO BE REPLACED). | ROBERTV | ROBERTV | | HE16 | C | 5280635 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/27/2016 | ELEVATOR LOCKED OUT AT 2ND FLOOR DURING CONSTRUCTION. NO REPAIRS NOTED ON 5 YEAR TEST DONE | ERIC | ERIC | | H02 | C | 5185445 |
JP MORGAN CHASE BANK, NA | H06 | C | 02/16/2016 | WITNESSED TRACTION SAFETY TEST W/ OTIS -- CAB DOOR RESTRICTOR BAR IS MISSING, EMERGENCY LIGHTS AND BELL ARE NOT WORKING, SUSPENSION ROPES AT TOP FLOOR EXCEED ALLOWABLE VALLEY WIRE BREAKS PER LAY (ALL ROPES WILL NEED TO BE REPLACED). A 90 DAY PERIOD WILL BE GIVEN TO ADDRESS ALL ITEMS. NEED COMPLETE MAINTENANCE CONTROL PROGRAM ONSITE. (Receipt #1313289) | ROBERTV | ROBERTV | | H06 | C | 5135137 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/21/2015 | 5YR 9-10 OTIS--5YR SAFETY TEST DUE / LOCKS FOR MACHINE ROOM ACCESS HAVE BEEN CHANGED, SEE MGR FOR ACCESS (Receipt #1296655) | TOM | TOM | | H01 | C | 5069978 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/28/2015 | 5 YEAR 9/10 OTIS AND LOCKBOX, HO2 | ERIC | ERIC | | H02 | C | 4944723 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/17/2014 | 5YR 9-10 OTIS W/ LOCKBOX @ ROOF ENTRY (Receipt #1227672) | TOM | TOM | | H01 | C | 4839316 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/07/2014 | 5 YEAR 9/10 OTIS AND LOCKBOX. | ERIC | ERIC | | H02 | C | 4715615 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/04/2013 | 5YR 9-10-OTIS (Receipt #1163866) | TOM | TOM | | H01 | C | 4633830 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/12/2013 | 5YR 9-10--OTIS | TOM | TOM | | H02 | C | 4515035 |
JP MORGAN CHASE BANK, NA | HE16 | C | 12/17/2012 | NOTIFIED 10/14/11--ELEVATOR MUST BE REGISTERED WITH THE STATE OF COLORADO, CANNOT ISSUE THE PERMIT TO OPERATE UNTIL THIS ELEVATOR IS REGISTERED. | JOHNW | JOHNW | | HE16 | C | 4441029 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/02/2012 | 5YR 9-10 (Receipt #1090102) | TOM | TOM | | H01 | C | 4410538 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/09/2012 | 5 YR 9-10--OTIS | TOM | TOM | | H02 | C | 4303456 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/14/2011 | ELEVATOR MUST BE REGISTERED WITH THE STATE, CANNOT ISSUE THE PERMIT TO OPERATE UNTIL THIS ELEVATOR IS REGISTERED ------------------------------------------------5YR 9-10 | TOM | TOM | | H01 | C | 4229140 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/11/2011 | 5YR 9-10--OTIS | TOM | TOM | | H02 | C | 4142457 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/11/2010 | 5 YEAR 9/10 OTIS (Receipt #938336) | ERIC | ERIC | | H01 | C | 4053966 |
JP MORGAN CHASE BANK, NA | HE16 | C | 09/07/2010 | ELEVATOR MOD. NEW MACHINE, CONTROLLER, DOOR OPERATOR, CAB INTERIOR, FIRE FIGHTERS SERVICE, GOVERNOR, MACHINE ROOM ETC... SPRINKLER HEAD REMOVED FROM MACHINE ROOM. NEW 5 YEAR SAFETY INSPECTION COMPLETED. SEE PERMIT H24089 | ERIC | ERIC | | HE16 | C | 4035946 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/13/2010 | 5 yr 3-09--otis--phone / light bulb gusrding / floor designation numbers at all landings | TOM | TOM | | H02 | C | 3968317 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/08/2009 | OTIS. KONE SERVICE 5 YR 3/09. BUILDING BEING REMODELED, ELEVATOR STILL IN USE BY CONTRACTORS (Receipt #880015) | ERIC | ERIC | | H01 | C | 3896198 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/30/2009 | BLDG LOCKED--UNDER MAJOR REMODEL--NO ACCESS TO BLDG | TOM | TOM | | H02 | C | 3829733 |
JP MORGAN CHASE BANK, NA | H06 | C | 03/24/2009 | 5 YEAR SAFETY TEST BY KONE. NOT WITNESSED BY PPRBD | ERIC | ERIC | | H06 | C | 3862491 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/07/2008 | CAR IS STILL NOT IN USE--SAME COMMENTS AS APRIL 08 INSPECTION (Receipt #833703) | TOM | TOM | | H01 | C | 3764231 |
JP MORGAN CHASE BANK, NA | H02 | P | 04/30/2008 | OTIS--5 YR EXPIRED LAST TEST 5-02--DOOR CLOSER MALFUNCTION--NO LIGHTS IN CAR--LOCKED OUT OF SERVICE AT MAINLINE DISCONNECT | TOM | TOM | | H02 | P | 3668314 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/31/2007 | 5 YR 5-02--NO MACH RM ACCESS RE-CHECK | TOM | TOM | | H01 | C | 496015 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/27/2007 | 5 YR 5-02--OTIS LOUD DOOR CHATTER--CALLED BARRY | TOM | TOM | | H02 | C | 496009 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/31/2006 | 5 YR 5-02 --- OTIS | LES | LES | | H01 | C | 496002 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/28/2006 | 5 YR 5-02--OTIS | TOM | TOM | | H02 | C | 495996 |
JP MORGAN CHASE BANK, NA | H01 | C | 10/28/2005 | 5 YR 5-02--OTIS | TOM | TOM | | H01 | C | 495988 |
JP MORGAN CHASE BANK, NA | H02 | C | 04/28/2005 | OTIS--CAR NOT WORKING -- BANK NOTIFIED OTIS | TOM | TOM | | H02 | C | 495981 |
BANK ONE REAL ESTATE | H01 | C | 10/07/2004 | 5 YR 5-02 --- OTIS
| LES | LES | | H01 | C | 495974 |
BANK ONE REAL ESTATE | H02 | C | 04/19/2004 | 5 YR 5-02 --- OTIS | LES | LES | | H02 | C | 495967 |
BANK ONE REAL ESTATE | H01 | C | 10/13/2003 | 5 YR 5-02 | LES | LES | | H01 | C | 495957 |
BANK ONE REAL ESTATE | H02 | C | 04/24/2003 | | TOM | TOM | | H02 | C | 495948 |
BANK ONE REAL ESTATE | H01 | C | 04/24/2003 | 5 YR 5-02--OTIS | TOM | TOM | | H01 | C | 495938 |
BANK ONE REAL ESTATE | H02 | C | 10/30/2002 | 5 YR 5-02--OTIS | TOM | TOM | | H02 | C | 495923 |
BANK ONE REAL ESTATE | H03 | C | 10/30/2002 | | TOM | TOM | | H03 | C | 495932 |
BANK ONE REAL ESTATE | H01 | P | 04/25/2002 | OTIS--5 YR EXPIRED--LAST TEST 5-94--FAXED | TOM | TOM | | H01 | P | 495915 |
BANK ONE REAL ESTATE | H02 | P | 10/11/2001 | NEED 5 YR TEST | TOM | TOM | | H02 | P | 495907 |
BANK ONE REAL ESTATE | H01 | C | 04/13/2001 | 5 YR 5-96--OTIS | TOM | TOM | | H01 | C | 495899 |
BANK ONE REAL ESTATE | H02 | C | 10/24/2000 | 5 YR 5-96 OTIS | TOM | TOM | | H02 | C | 495892 |
BANK ONE REAL ESTATE | H01 | C | 04/26/2000 | no key for roof access -- need to check 5yr test | LES | LES | | H01 | C | 495732 |
BANK ONE REAL ESTATE | H02 | C | 10/29/1999 | PHONE INOP, NEED FIRE EXT FOR M/R | DAVEL | DAVEL | | H02 | C | 495884 |
BANK ONE REAL ESTATE | H01 | P | 04/22/1999 | phone and low light in cab | RUSS | RUSS | | H01 | P | 495725 |
BANK ONE REAL ESTATE | H02 | C | 10/28/1998 | | RUSS | RUSS | | H02 | C | 495718 |
BANK ONE REAL ESTATE | H01 | C | 04/07/1998 | 5yr 1994 | RUSS | RUSS | | H01 | C | 495710 |
BANK ONE REAL ESTATE | H02 | C | 10/29/1997 | | ELDON | ELDON | | H02 | C | 495876 |
BANK ONE REAL ESTATE | H01 | C | 04/14/1997 | 5yr7-96 | RUSS | RUSS | | H01 | C | 495867 |
BANK ONE REAL ESTATE | H02 | C | 10/11/1996 | | RUSS | RUSS | | H02 | C | 495859 |
BANK ONE REAL ESTATE | H01 | C | 04/09/1996 | | RUSS | RUSS | | H01 | C | 495852 |
BANK ONE REAL ESTATE | H02 | C | 10/28/1995 | 5yr4-94 | RUSS | RUSS | | H02 | C | 495843 |
BANK ONE REAL ESTATE | H01 | C | 04/03/1995 | | RUSS | RUSS | | H01 | C | 495834 |
BANK ONE REAL ESTATE | H02 | C | 10/14/1994 | 5YR,4-94 | RUSS | RUSS | | H02 | C | 495825 |
BANK ONE REAL ESTATE | H01 | P | 04/11/1994 | 5YR.EXPIRED | RUSS | RUSS | | H01 | P | 495819 |
BANK ONE REAL ESTATE | H02 | C | 10/27/1993 | 5YR11-88 | RUSS | RUSS | | H02 | C | 495812 |
BANK ONE REAL ESTATE | H01 | C | 04/05/1993 | 5YR 10-88 | RUSS | RUSS | | H01 | C | 495804 |
BANK ONE REAL ESTATE | H02 | C | 10/21/1992 | | RUSS | RUSS | | H02 | C | 495797 |
BANK ONE REAL ESTATE | H01 | C | 04/01/1992 | | RUSS | RUSS | | H01 | C | 495789 |
BANK ONE REAL ESTATE | H02 | C | 10/16/1991 | 5YR 10-88 | RUSS | RUSS | | H02 | C | 495780 |
BANK ONE REAL ESTATE | H01 | C | 04/02/1991 | | RUSS | RUSS | | H01 | C | 495773 |
BANK ONE REAL ESTATE | H02 | C | 10/17/1990 | | RUSS | RUSS | | H02 | C | 495764 |
BANK ONE REAL ESTATE | H01 | C | 04/18/1990 | | RUSS | RUSS | | H01 | C | 495757 |
BANK ONE REAL ESTATE | H02 | C | 10/23/1989 | | RUSS | RUSS | | H02 | C | 495748 |
BANK ONE REAL ESTATE | H16 | C | 04/24/1989 | INIT INSP,PERM ISSD,ORDER:PHN INOP,NEED PT LDR | RUSS | RUSS | | H16 | C | 495740 |