U S OLYMPIC COMMITTEE | H06 | C | 04/23/2024 | WITNESSED 5 YEAR TEST W/ OTIS -- EMERGENCY PHONE IS NONFUNCTIONAL WHEN ALL POWER IS DISCONNECTED (Receipt #2056003) | BENH | BENH | | H06 | C | 8061244 |
U S OLYMPIC COMMITTEE | H01 | C | 01/16/2024 | ANNUAL 12/22 -- MONTGOMERY W/ OTIS MODERNIZATION & KEYS -- ANNUAL CATEGORY 1 HYDRAULIC TEST IS PAST DUE -- 30 DAYS TO ADDRESS (Receipt #2024938) (Moved H06 to align with H02 RV) | BENH | BENH | | H01 | C | 7969036 |
U S OLYMPIC COMMITTEE | H02 | C | 07/26/2023 | H02 - ANNUAL 12/2022 - MONTGOMERY WITH OTIS MODERNIZATION AND KEYS | MIKEM | MIKEM | | H02 | C | 7808507 |
U S OLYMPIC COMMITTEE | H01 | C | 01/10/2023 | ANNUAL 12/22 -- MONTGOMERY W/ OTIS MOD & KEYS (Receipt #1925597) | BENH | BENH | | H01 | C | 7630437 |
U S OLYMPIC COMMITTEE | H02 | C | 07/29/2022 | HO2 -- ANNUAL 12/2021 -- MONTGOMERY WITH OTIS SERVICE -- SEE PREVIOUS INSPECTION COMMENTS cat 1 12/22 BH | MIKEM | MIKEM | | H02 | C | 7464364 |
U S OLYMPIC COMMITTEE | H01 | C | 01/25/2022 | ANNUAL 12/2021-- MONTGOMERY WITH OTIS MOD AND KEYS--/ VISUAL INDICATOR AT PHASE 1 KEY SWITCH IS NOT ILLUMINATING WHILE TESTING FIRE SERVICE (Receipt #1838962) | MIKEM | MIKEM | | H01 | C | 7250004 |
U S OLYMPIC COMMITTEE | H02 | C | 07/12/2021 | RP 12/20 MONTGOMERY, OTIS KEYS AND SERVICE, HO2 cat 1 12/21 | ERIC | ERIC | | H02 | C | 7031474 |
U S OLYMPIC COMMITTEE | H01 | C | 01/20/2021 | CAT1 -- 12/20 -- MONTGOMERY W/ OTIS KEYS AND SERVICE. ELEVATOR EMERGENCY PHONE WILL NOT MAKE TWO-WAY COMMUNICATION. UPPER HORIZONTAL TRIM PIECES ABOVE INTERIOR CAB PANELS NEED TO BE SECURED W/ SCREWS, VELCRO IS NOT ACCEPTABLE. (Receipt #1744086) | ROBERTV | ROBERTV | | H01 | C | 6841530 |
U S OLYMPIC COMMITTEE | H02 | C | 07/22/2020 | H02 -- RP -- 10/19 -- MONTGOMERY W/ OTIS SERVICE | ROBERTV | ROBERTV | | H02 | C | 6646128 |
U S OLYMPIC COMMITTEE | H01 | C | 01/15/2020 | MODERNIZATION PERFORMED 10/2019 (Receipt #1655835) | ROBERTV | ROBERTV | | H01 | C | 6453217 |
U S OLYMPIC COMMITTEE | H06 | C | 10/08/2019 | 5 year at mod | ERIC | ERIC | | H06 | C | 6361302 |
U S OLYMPIC COMMITTEE | HE16 | C | 10/08/2019 | NEW TANK UNIT, CONTROLLER, DOOR OPERATORS, CAR DOORS, COP, HALL CALLS, CAB FINISH. SEE M48011 | ERIC | ERIC | | HE16 | C | 6361165 |
U S OLYMPIC COMMITTEE | HE16 | C | 08/15/2019 | MEETING WITH OTC, OTIS, BERWICK, FIRE ALARM FOR WORK BY OTHERS FOR MOD | ERIC | ERIC | | HE16 | C | 6302483 |
U S OLYMPIC COMMITTEE | H02 | C | 07/25/2019 | H02 -- RP -- 2/19 -- MONTGOMERY W/ OTIS SERVICE. ALL DOOR CLUTCH ROLLERS ARE WORN OUT. CAB DOOR SEPARATES FROM HOISTWAY DOORS ON ALL FLOORS. NEED TO COMPLETELY FILL OUT TEST FORM TO INCLUDE BUILDING NUMBER AND MANUFACTURER JOB CONTRACT NUMBER, AND SEND COPIES TO PPRBD. | ROBERTV | ROBERTV | | H02 | C | 6277273 |
U S OLYMPIC COMMITTEE | H01 | C | 01/17/2019 | REQUIRED ANNUAL CATEGORY 1 TESTING IS WAY PAST DUE, LAST PERFORMED 7/2017......... NEEDS COMPLETED BY 1/31/2019. DOOR PROBLEMS AS LISTED IN PREVIOUS INSPECTIONS ARE IN THE WORKS TO BE REPAIRED. (Receipt #1570287) | ROBERTV | ROBERTV | | H01 | C | 6081365 |
U S OLYMPIC COMMITTEE | H02 | C | 07/31/2018 | RP -- 7/17 -- MONTGOMERY W/ OTIS SERVICE. EMERGENCY PHONE STILL NOT WORKING, DOOR PROBLEMS AS LISTED IN PREVIOUS INSPECTION STILL PRESENT. FACILITIES IS TROUBLESHOOTING PHONE LINE. ANNUAL CATEGORY 1 TESTING IS DUE. WILL FOLLOW UP IN 30 DAYS | ROBERTV | ROBERTV | | H02 | C | 5918681 |
U S OLYMPIC COMMITTEE | HE16 | C | 07/10/2018 | REALIGNED INSPECTIONS | ROBERTV | ROBERTV | | HE16 | C | 5898097 |
U S OLYMPIC COMMITTEE | H02 | C | 01/22/2018 | RP -- 7/17 -- MONTGOMERY W/ OTIS SERVICE. EMERGENCY PHONE NOT WORKING. ALL DOOR CLUTCH ROLLERS ARE WORN OUT. CAB DOOR SEPARATES FROM HOISTWAY DOOR ON LOWER LEVEL AND MAIN REAR DOORS. CAB DOOR CLUTCH CLIPS DOOR ROLLERS WHEN COMING INTO FLOORS. LOWER LEVEL HOISTWAY DOOR METAL IS CRACKED AND FATIGUED WHERE DOOR ROLLER ASSEMBLY MOUNTS. LOWER LEVEL HOISTWAY FASCIA NEEDS SECURED TO LANDING SILL. | ROBERTV | ROBERTV | | H02 | C | 5744044 |
U S OLYMPIC COMMITTEE | H01 | C | 07/25/2017 | REQUIRED ANNUAL CATEGORY 1 TESTING IS EXPIRED, LAST PERFORMED 2/2016. ITEMS AS LISTED ON PREVIOUS INSPECTION HAVE YET TO BE ADDRESSED ---- ALL DOOR CLUTCH ROLLERS ARE WORN OUT AND OUT OF ADJUSTMENT, HOISTWAY FASCIA FOR ALL LANDINGS NEEDS SECURED, CAB DOOR CLUTCH IS CLIPPING DOOR ROLLERS WHEN COMING INTO FLOORS. WHERE DOOR ROLLER ASSEMBLIES ATTACH TO HOISTWAY DOORS METAL IS CRACKED AND FATIGUED. 30 DAYS TO ADDRESS ALL (Rp Performed 7/27/2017) (Receipt #1441727) | ROBERTV | ROBERTV | | H01 | C | 5575157 |
U S OLYMPIC COMMITTEE | H02 | C | 01/26/2017 | RP -- 2/16 -- MONTGOMERY W/ OTIS SERVICE. ALL DOOR CLUTCH ROLLERS ARE WORN OUT AND OUT OF ADJUSTMENT, UPPER FRONT FLOOR HOISTWAY DOOR IS CRACKED AND BROKEN WHERE DOOR CLUTCH ATTACHES, HOISTWAY FASCIA FOR ALL FLOOR LANDINGS NEEDS SECURED PROPERLY. | ROBERTV | ROBERTV | | H02 | C | 5399696 |
U S OLYMPIC COMMITTEE | H01 | C | 07/01/2016 | THIS VISIT SKIPPED IN LIEU OF WITNESS TEST PERFORMED 2/2016 (Receipt #1339262) | ROBERTV | ROBERTV | | H01 | C | 5235885 |
U S OLYMPIC COMMITTEE | H06 | C | 02/05/2016 | WITNESSED HYDRO SAFETY TEST W/ OTIS -- NO ISSUES
| ROBERTV | ROBERTV | | H06 | C | 5129272 |
U S OLYMPIC COMMITTEE | H02 | C | 01/28/2016 | PRESSURE RELIEF TEST STILL EXPIRED - WITNESS TEST SCHEDULED FOR FEBRUARY | ROBERTV | ROBERTV | | H02 | C | 5125655 |
U S OLYMPIC COMMITTEE | H01 | C | 07/29/2015 | REQUIRED ANNUAL PRESSURE RELIEF TEST EXPIRED, LAST PERFORMED 6/2014. DOORS AT ALL THREE ENTRANCES DISCONNECT FROM DOOR CLUTCH, CLUTCH ROLLERS ARE DAMAGED (2ND NOTICE), 5 YEAR WITNESS TEST DUE 1/2016 (Receipt #1277525) | ROBERTV | ROBERTV | | H01 | C | 5003732 |
U S OLYMPIC COMMITTEE | H02 | C | 01/05/2015 | RP 6-14 MONTGOMERY | TOM | TOM | | H02 | C | 4894310 |
U S OLYMPIC COMMITTEE | H01 | C | 07/21/2014 | RP 6/14 MKE. OTIS SERVICE. EMERGENCY PHONE NOT WORKING, PICK UP ROLLERS AT UPPER LANDING DAMAGED, LOWER PICKUP ROLLER ASSEMBLY RIPPED OUT OF DOOR, ELEVATOR QUIT RUNNING WHILE INSPECTING HOISTWAY, SHUT OFF AT DISCONNECT (Receipt #1208498) | ERIC | ERIC | | H01 | C | 4780453 |
U S OLYMPIC COMMITTEE | H02 | C | 01/17/2014 | RP 3-13-MKE-OTIS SERVICE ALL CARS--PHONE IN CAR NOT WORKING | TOM | TOM | | H02 | C | 4681767 |
U S OLYMPIC COMMITTEE | H01 | C | 07/25/2013 | RP 3/13 MKE. OTIS SERVICE (Receipt #1144240) | ERIC | ERIC | | H01 | C | 4571093 |
U S OLYMPIC COMMITTEE | H02 | C | 01/28/2013 | RP 3/12 MKE. OTIS SERVICE. REAR HOISTWAY DOOR SEPARATES FROM CAR DOOR WHEN TESTING DOOR FORCE AND THERE IS SOME BROKEN/DISCONNECTED LINKAGE AT SAME DOOR, EMERGENCY PHONE NOT WORKING | ERIC | ERIC | | H02 | C | 4462233 |
U S OLYMPIC COMMITTEE | H01 | C | 07/16/2012 | RP 3/12 MKE, OTIS SERVICE (Receipt #1060643) | ERIC | ERIC | | H01 | C | 4342154 |
U S OLYMPIC COMMITTEE | H02 | C | 01/27/2012 | RP 1/11 MKE. OTIS SERVICE | ERIC | ERIC | | H02 | C | 4265198 |
U S OLYMPIC COMMITTEE | H01 | C | 07/25/2011 | RP 1-11--MONTGOMERY--STATE REGISTRATION # CP11-001218 (Receipt #989024) | TOM | TOM | | H01 | C | 4183773 |
U S OLYMPIC COMMITTEE | H02 | C | 01/27/2011 | RP 1-11--MONTGOMEREY | TOM | TOM | | H02 | C | 4106072 |
U S OLYMPIC COMMITTEE | H01 | C | 07/02/2010 | rp 1-10--montgomery machine room storage (Receipt #923263) | TOM | TOM | | H01 | C | 4017358 |
U S OLYMPIC COMMITTEE | H02 | C | 01/29/2010 | rp 1-10--montgomery | TOM | TOM | | H02 | C | 3938578 |
U S OLYMPIC COMMITTEE | H01 | C | 07/22/2009 | MONTGOMERY. OTIS SERVICE RP 1/09. (Receipt #868289) | ERIC | ERIC | | H01 | C | 3861531 |
U S OLYMPIC COMMITTEE | H02 | C | 01/14/2009 | MONTGOMERY. RELIEF PRESSURE TEST EXPIRED. LAST TEST 10/07. ELEVATOR OUT OF ORDER AT TIME OF INSPECTION | ERIC | ERIC | | H02 | C | 3790673 |
U S OLYMPIC COMMITTEE | H01 | C | 07/15/2008 | RP 10-07 [350 ] --- OTIS (Receipt #816383) | LES | LES | | H01 | C | 3708584 |
U S OLYMPIC COMMITTEE | H02 | C | 01/29/2008 | RP 10-07 --- OTIS | LES | LES | | H02 | C | 503604 |
U S OLYMPIC COMMITTEE | H01 | C | 07/24/2007 | RP TEST DUE --- OTIS [ TOLD DEE IN MAINTENANCE ] | LES | LES | | H01 | C | 503596 |
U S OLYMPIC COMMITTEE | H02 | C | 01/31/2007 | RP 5-06 --- OTIS | LES | LES | | H02 | C | 503589 |
U S OLYMPIC COMMITTEE | H01 | C | 07/31/2006 | RP TEST DUE --- OTIS | LES | LES | | H01 | C | 503580 |
U S OLYMPIC COMMITTEE | H02 | C | 01/30/2006 | RP 5-05 --- OTIS | LES | LES | | H02 | C | 503572 |
U S OLYMPIC COMMITTEE | H01 | C | 07/28/2005 | RP--5--05--OTIS | JOHNW | JOHNW | | H01 | C | 503564 |
U S OLYMPIC COMMITTEE | H02 | C | 01/31/2005 | RP TEST DUE --- OTIS --- NEED SIGN LOWER LEVEL --- STOP SWITCH AND ALARM INOP. IN CAR | LES | LES | | H02 | C | 503556 |
U S OLYMPIC COMMITTEE | H01 | C | 08/26/2004 | MONTGOMERY--MACH TAGGED 3-03--STOP SWITCH & ALARM BELLS IN CAR INOP | TOM | TOM | | H01 | C | 503548 |
U S OLYMPIC COMMITTEE | H02 | C | 01/28/2004 | RP 3-03--OTIS--CAR SCRAPING FACIA IN HOISTWAY--TOGGLE ON STOP SWITCH IN CAR BROKEN | TOM | TOM | | H02 | C | 503540 |
U S OLYMPIC COMMITTEE | H01 | C | 07/30/2003 | RP 3-03--OTIS | TOM | TOM | | H01 | C | 503524 |
U S OLYMPIC COMMITTEE | H03 | C | 07/30/2003 | | TOM | TOM | | H03 | C | 503532 |
U S OLYMPIC COMMITTEE | H02 | P | 01/31/2003 | SCHINDLER--RP EXP | TOM | TOM | | H02 | P | 503516 |
U S OLYMPIC COMMITTEE | H01 | C | 07/30/2002 | RP 8-01--SCHNDLER--PHONE INOP | TOM | TOM | | H01 | C | 503507 |
U S OLYMPIC COMMITTEE | H02 | C | 01/31/2002 | RP 8-01 --- SIGNS | LES | LES | | H02 | C | 503500 |
U S OLYMPIC COMMITTEE | H03 | C | 09/25/2001 | RP 9-01 | TOM | TOM | | H03 | C | 503492 |
U S OLYMPIC COMMITTEE | H01 | C | 07/31/2001 | RP 7-00--SCHINDLER--LEVELING OFF | TOM | TOM | | H01 | C | 503484 |
U S OLYMPIC COMMITTEE | H02 | C | 01/31/2001 | RP 7-00 | LES | LES | | H02 | C | 503471 |
U S OLYMPIC COMMITTEE | H01 | C | 07/21/2000 | RP 7-99--MONTGOMERY | TOM | TOM | | H01 | C | 503463 |
U S OLYMPIC COMMITTEE | H02 | C | 01/28/2000 | MAIN LEVEL CALL BUTTON LITE OUT | DAVEL | DAVEL | | H02 | C | 503239 |
U S OLYMPIC COMMITTEE | H01 | P | 07/15/1999 | BLDG 4-MAIN---OTIS--INSTALL 6-87---NO ACESS TO MACH RM--LEVELING AT BSMNT LANDING--DODWN CALL BUTTON @ 1ST FLOOR INOP | TOM | TOM | | H01 | P | 503451 |
U S OLYMPIC COMMITTEE | H02 | C | 01/25/1999 | | RUSS | RUSS | | H02 | C | 503231 |
U S OLYMPIC COMMITTEE | H01 | P | 07/01/1998 | lower hall call button sticks causing door to not close operator just cycles | DAVEL | DAVEL | | H01 | P | 503223 |
U S OLYMPIC COMMITTEE | H02 | C | 01/08/1998 | | RUSS | RUSS | | H02 | C | 503443 |
U S OLYMPIC COMMITTEE | H01 | C | 07/15/1997 | | RUSS | RUSS | | H01 | C | 503435 |
U S OLYMPIC COMMITTEE | H02 | C | 01/22/1997 | | RUSS | RUSS | | H02 | C | 503427 |
U S OLYMPIC COMMITTEE | H01 | C | 07/17/1996 | | RUSS | RUSS | | H01 | C | 503419 |
U S OLYMPIC COMMITTEE | H02 | C | 01/26/1996 | | RUSS | RUSS | | H02 | C | 503411 |
U S OLYMPIC COMMITTEE | H01 | R | 07/24/1995 | phn not wking. | RUSS | RUSS | | H01 | R | 503404 |
U S OLYMPIC COMMITTEE | H02 | C | 01/30/1995 | | RUSS | RUSS | | H02 | C | 503393 |
U S OLYMPIC COMMITTEE | H01 | C | 07/21/1994 | | RUSS | RUSS | | H01 | C | 503385 |
U S OLYMPIC COMMITTEE | H02 | C | 01/25/1994 | | RUSS | RUSS | | H02 | C | 503377 |
U S OLYMPIC COMMITTEE | H01 | C | 07/28/1993 | BLDG.16 FOR MAINT.MAN,,RP5-93 | RUSS | RUSS | | H01 | C | 503369 |
U S OLYMPIC COMMITTEE | H02 | R | 01/25/1993 | RP EXP | RUSS | RUSS | | H02 | R | 503361 |
U S OLYMPIC COMMITTEE | H01 | P | 07/01/1992 | R.P.???? | RUSS | RUSS | | H01 | P | 503353 |
U S OLYMPIC COMMITTEE | H02 | C | 01/06/1992 | | RUSS | RUSS | | H02 | C | 503345 |
U S OLYMPIC COMMITTEE | H01 | C | 07/12/1991 | | RUSS | RUSS | | H01 | C | 503338 |
U S OLYMPIC COMMITTEE | H02 | C | 01/24/1991 | | RUSS | RUSS | | H02 | C | 503329 |
U S OLYMPIC COMMITTEE | H01 | P | 07/12/1990 | RP TST | RUSS | RUSS | | H01 | P | 503321 |
U S OLYMPIC COMMITTEE | H02 | P | 01/29/1990 | | RUSS | RUSS | | H02 | P | 503313 |
U S OLYMPIC COMMITTEE | H16 | C | 07/24/1989 | INIT INSP,PERM ISSD,ORDER:RP TST | RUSS | RUSS | | H16 | C | 503247 |