BROOKDALE SKYLINE | H03 | C | 04/18/2024 | 30 DAY RED TAG NOTICE POSTED. ALL ITEMS TO BE ADDRESS BY 5/18 TO AVOID SERVICE INTERRUPTION. / CLEAN PIT. PIT HAS DEBRIS AND STANDING WATER IN IT. / SUMP PUMP NEEDS REPAIR/REPLACEMENT. / SEE IMAGES ATTACHED TO PERMIT. (Receipt #2054833)(pit cleaning has been addressed -- mlm 5/1/24) | MATTM | MATTM | | H03 | C | 8057578 |
BROOKDALE SKYLINE | H01 | C | 02/13/2024 | ANNUAL 3/23 - OTIS W/SERVICE - PHONE LINE DEAD / SUMP PUMP HAS FAILED, THERE IS STANDING WATER IN THE PIT / OIL BUCKETS ARE KNOCKED OVER / BUILDING TO MAINTAIN FIRE SERVICE LOGS / 60 DAYS TO ADDRESS........HOLD PERMIT TO OPERATE / (Receipt #2033587) | MATTM | MATTM | | H01 | C | 7994945 |
BROOKDALE SKYLINE | H02 | C | 08/15/2023 | HO2 -- ANNUAL 3/23 -- OTIS & LOCKBOX -- SEE PREVIOUS NOTES | BENH | BENH | | H02 | C | 7826271 |
BROOKDALE SKYLINE | H01 | C | 02/07/2023 | ANNUAL 02/2022 -- OTIS AND LOCKBOX --/ EMERGENCY LIGHT AND BELL ARE NON-FUNCTIONAL WITHOUT THE 110v CAB CIRCUIT --/ EMERGENCY TWO WAY COMMUNICATION MEANS IS NON-FUNCTIONAL --/ MONTHLY FIRE FIGHTERS SERVICE TESTING AND QUARTERLY EMERGENCY PHONE TESTING LOGS NOT BEING MAINTAINED --/ MAINTENANCE RECORDS AND OIL LOGS ARE NOT UP TO DATE --/ GROUND LEVEL HALL CALL IS STAYING ILLUMINATED CONSISTENTLY --/ ELEVATOR LIGHTING TO BE ADDRESSED (ONE BURNT BULB) --/ PPRBD NOTE: CATEGORY 1 HYDRAULIC TESTING IS DUE THIS MONTH --/ PERMIT TO OPERATE WILL NOT BE ISSUED UNTIL ITEMS ARE ADDRESSED (Receipt #1931678) (cat 1 -- 3/23, Emergency light and alarm bell working per report, Emergency phone failed and needs battery replaced per report DS) - (pprbd note: emergency phone working per mechanic and maintenance record pic mm) | MIKEM | MIKEM | | H01 | C | 7655811 |
BROOKDALE SKYLINE | H02 | C | 08/11/2022 | HO2 -- ANNUAL 02/2022 -- OTIS AND LOCKBOX | MIKEM | MIKEM | | H02 | C | 7478995 |
BROOKDALE SKYLINE | H01 | C | 02/07/2022 | ANNUAL 02/2021-- OTIS AND LOCK BOX--/ EMERGENCY LIGHT AND BELL NON FUNCTIONAL WITHOUT 110v CAB CIRCUIT--/ BUILDING TO PROVIDE ADEQUATE CAR LIGHTING (NEEDS 1 BULB)--/ (NOTE: CATEGORY 1 ANNUAL HYDRAULIC TEST IS DUE THIS MONTH) (Receipt #1841689) -- cat1 02/2022 mm | MIKEM | MIKEM | | H01 | C | 7261693 |
BROOKDALE SKYLINE | H02 | C | 08/19/2021 | H02 -- ANNUAL 2/2021 -- OTIS & LOCKBOX | RANDYB | RANDYB | | H02 | C | 7078245 |
BROOKDALE SKYLINE | H01 | C | 02/26/2021 | ANNUAL 2/2021 -- OTIS & LOCKBOX -- / ELEVATOR CYLINDER LEAKS EXCESSIVELY (Receipt #1753172) cat 1 2/21 | RANDYB | RANDYB | | H01 | C | 6882162 |
BROOKDALE SKYLINE | H02 | C | 08/31/2020 | H02 -- ANNUAL 2/2020 -- OTIS & LOCKBOX -- SEE NOTES FOR ACCESS -- / ELEVATOR PACKING NEEDS REPLACED | RANDYB | RANDYB | | H02 | C | 6690912 |
BROOKDALE SKYLINE | HE16 | C | 08/03/2020 | REALIGNED INSPECTIONS TO MATCH WITH OTHERS AT THIS SITE | ROBERTV | ROBERTV | | HE16 | C | 6658472 |
BROOKDALE SKYLINE | H02 | C | 02/28/2020 | WITNESSED 5YR HYDRO CATEGORY 1 TEST W/ OTIS--OTIS & LOCKBOX--ELEVATOR CAR MOVED 4 INCHES IN POSITION DURING POWER DOWN STATIC TEST / PACKING NEEDS REPLACED | CALE | CALE | | H02 | C | 6495635 |
BROOKDALE SKYLINE | H06 | C | 02/28/2020 | WITNESSED 5YR HYDRO CATEGORY 1 TEST W/ OTIS--OTIS & LOCKBOX--ELEVATOR CAR MOVED 4 INCHES IN POSITION DURING POWER DOWN STATIC TEST / PACKING NEEDS REPLACED | CALE | CALE | | H06 | C | 6495613 |
BROOKDALE SKYLINE | H01 | C | 08/22/2019 | RP--2--19--OTIS --AND LOCKBOX (Receipt #1624269) | JOHNW | JOHNW | | H01 | C | 6310009 |
BROOKDALE SKYLINE | H02 | C | 02/20/2019 | RP 2/18 OTIS AND LOCKBOX, HO2 cat 1 done 2/19 | ERIC | ERIC | | H02 | C | 6111621 |
BROOKDALE SKYLINE | H01 | C | 08/02/2018 | RP--2--18--OTIS AND LOCBKOX (Receipt #1523502) | JOHNW | JOHNW | | H01 | C | 5921672 |
BROOKDALE SKYLINE | H02 | C | 02/05/2018 | RP 1 17 OTIS AND LOCKBOX. RELIEF PRESSURE TEST EXPIRED, FIRE FIGHTERS PHASE 2 SIGN UNREADABLE | ERIC | ERIC | | H02 | C | 5757396 |
BROOKDALE SKYLINE | H01 | C | 08/21/2017 | RP--1--17--OTIS --AND LOCKBOX (Receipt #1447518) | JOHNW | JOHNW | | H01 | C | 5601336 |
BROOKDALE SKYLINE | H02 | C | 02/09/2017 | RP 1/17 OTIS AND LOCKBOX | ERIC | ERIC | | H02 | C | 5410577 |
BROOKDALE SKYLINE | H01 | C | 08/03/2016 | RP--2--16--OTIS AND LOCKBOX---------------------------------------------------PROBLEM WITH THE DOOR OPERATOR , DOOR CYCLES MULTIPLE TIMES BEFORE ELEVATOR WILL MOVE (Receipt #1346510) | JOHNW | JOHNW | | H01 | C | 5260236 |
BROOKDALE SKYLINE | H02 | C | 02/03/2016 | H02 - ITEMS WERE ADDRESSED 9/2015 | ROBERTV | ROBERTV | | H02 | C | 5127112 |
BROOKDALE SKYLINE | H01 | C | 08/26/2015 | THE ONLY REPAIRS MADE FROM PREVIOUS VIOLATIONS ARE: EMERGENCY LIGHTING WORKS BUT SHUTS OFF AFTER ACTIVATING ALARM BELL, PIT IS FLOODED. ELEVATOR IS SCHEDULED FOR REMOVAL FROM SERVICE 8/31/2015 | ROBERTV | ROBERTV | | H01 | C | 5022330 |
BROOKDALE SKYLINE | H06 | C | 03/12/2015 | WITNESSED 5 YEAR HYDRO SAFETY TEST W/ OTIS -- EMERGENCY LIGHTING AND ALARM NOT WORKING, BULB GUARDS IN CAR MISSING, CAR ENCLOSURE PANELING IS NOT SECURED, CAR DIRECTIONAL INDICATOR IS MISSING, PIT NEEDS CLEANED, MONTHLY FIRE SERVICE TEST LOG NEEDS MAINTAINED. (HAND WRITTEN VIOLATION DELIVERED TO EXECUTIVE DIRECTOR - SEE IMAGES) | ROBERTV | ROBERTV | | H06 | C | 4916044 |
BROOKDALE SKYLINE | H02 | C | 02/24/2015 | RP -- 3/14 -- OTIS AND LOCKBOX. ITEMS FROM PREVIOUS INSPECTION STILL PRESENT: EMERGENCY LIGHTING AND ALARM NOT WORKING, BULB GUARDS IN CAR MISSING, CAR ENCLOSURE PANELING IS NOT SECURED, CAR DIRECTIONAL INDICATOR IS MISSING, PIT NEEDS CLEANED, MONTHLY FIRE SERVICE TEST LOG NEEDS MAINTAINED. 5 YEAR WITNESS TEST DUE 3/2015. (SECOND NOTICE) -- THESE ITEMS NEED REPAIRED BY INSPECTION IN AUGUST OR ELEVATOR WILL BE REMOVED FROM SERVICE, CORPORATE OFFICE WILL ALSO BE NOTIFIED. | ROBERTV | ROBERTV | | H02 | C | 4907905 |
BROOKDALE SKYLINE | H01 | C | 08/06/2014 | RP -- 3/14 -- OTIS AND LOCKBOX. EMERGENCY PHONE, LIGHT OR ALARM NOT WORKING, BULB GUARDS MISSING, INTERIOR CAR ENCLOSURE PANELING HAS BECAME UNSECURED, CAR DOOR JAMB DIRECTIONAL INDICATOR IS MISSING, NEED FIREMAN PHASE I OPERATION PLACARD AT EGRESS LEVEL, PIT NEEDS CLEANED (HAS BEEN SUBJECT TO PREVIOUS FLOODING), MONTHLY FIRE SERVICE TESTING AND LOG NEEDS TO BE MAINTAINED. 5 YEAR WITNESS TEST IS ALSO REQUIRED (Receipt #1212289) | ROBERTV | ROBERTV | | H01 | C | 4792092 |
BROOKDALE SKYLINE | H02 | C | 02/11/2014 | HO2 | JOHNW | JOHNW | | H02 | C | 4685067 |
BROOKDALE SKYLINE | H01 | C | 08/05/2013 | RP--88--12--OTIS AND LOCKBOX (Receipt #1146307) | JOHNW | JOHNW | | H01 | C | 4577991 |
BROOKDALE SKYLINE | H02 | C | 02/06/2013 | NO MACHINE ROOM ACCESS LAST RP 5--11--OTIS | JOHNW | JOHNW | | H02 | C | 4467256 |
BROOKDALE SKYLINE | H01 | C | 08/09/2012 | RP-5--11--OTIS -- AND LOCKBOX PRESSURE RELIEF TEST EXPIRED (Receipt #1068823) | JOHNW | JOHNW | | H01 | C | 4358175 |
BROOKDALE SKYLINE | H02 | C | 02/03/2012 | RP--5--11--OTIS AND LOCKBOX | JOHNW | JOHNW | | H02 | C | 4267498 |
BROOKDALE SKYLINE | H01 | C | 08/03/2011 | RP--5--11--OTIS AND LOCKBOX (Receipt #991034) | JOHNW | JOHNW | | H01 | C | 4187671 |
BROOKDALE SKYLINE | H02 | C | 02/07/2011 | RP--4--10--OTIS AND LOCKBOX | JOHNW | JOHNW | | H02 | C | 4108201 |
BROOKDALE SKYLINE | H01 | C | 08/05/2010 | RP--4--10--OTIS--LOCKBOX (Receipt #924332) | JOHNW | JOHNW | | H01 | C | 4019866 |
BROOKDALE SKYLINE | H02 | C | 02/04/2010 | RP--9--08--OTIS--OTIS LOCKBOX--RELIEF PRESSURE TEST EXPIRED | JOHNW | JOHNW | | H02 | C | 3940381 |
BROOKDALE SKYLINE | H01 | C | 08/06/2009 | RP--9--08--OTIS AND LOCKBOX--WATER IN THE JACK HOLE (Receipt #870535) | JOHNW | JOHNW | | H01 | C | 3868143 |
BROOKDALE SKYLINE | H02 | C | 02/04/2009 | RP--9--08--OTIS AND LOCKBOX | JOHNW | JOHNW | | H02 | C | 3798561 |
BROOKDALE SKYLINE | H01 | C | 08/01/2008 | TRAINING WITH JOHN W. OTIS LOCKBOX. RP EXPIRED 7/07, EMERGENCY PHONE INOPERABLE. NEED FIRE EXT. AT MACHINE ROOM (Receipt #819494) | ERIC | ERIC | | H01 | C | 3718657 |
BROOKDALE SKYLINE | H02 | C | 02/01/2008 | RP 7-07 --- OTIS ELEV AND LOCKBOX | LES | LES | | H02 | C | 884820 |
BROOKDALE SKYLINE | H01 | C | 08/03/2007 | RP 7-07 --- OTIS ELEVATOR AND LOCKBOX | LES | LES | | H01 | C | 884809 |
BROOKDALE SKYLINE | H02 | C | 02/02/2007 | RP 7-06 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H02 | C | 884802 |
BROOKDALE SKYLINE | H01 | C | 08/03/2006 | RP 7-06 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H01 | C | 884793 |
BROOKDALE SKYLINE | H02 | C | 02/02/2006 | RP 7-05 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H02 | C | 884786 |
BROOKDALE SKYLINE | H01 | C | 08/01/2005 | RP 7-05 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H01 | C | 884779 |
BROOKDALE SKYLINE | H02 | C | 02/02/2005 | RP 5-04 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H02 | C | 884773 |
BROOKDALE SKYLINE | H01 | C | 08/02/2004 | RP 5-04 --- OTIS ELEVATOR AND LOCKBOX --- WATER IN PIT | LES | LES | | H01 | C | 884766 |
BROOKDALE SKYLINE | H02 | C | 02/02/2004 | RP 4-03 --- OTIS ELEVATOR AND LOCKBOX | LES | LES | | H02 | C | 884758 |
BROOKDALE SKYLINE | H01 | C | 08/05/2003 | RP 4-03 --- NEED LIGHT BULB GUARDS | LES | LES | | H01 | C | 884751 |
BROOKDALE SKYLINE | H02 | C | 02/12/2003 | RP 4-02 | LES | LES | | H02 | C | 884743 |
BROOKDALE SKYLINE | H01 | C | 08/05/2002 | RP 6-02 | LES | LES | | H01 | C | 884737 |
BROOKDALE SKYLINE | H02 | C | 02/01/2002 | RP 3-01 | LES | LES | | H02 | C | 884729 |
BROOKDALE SKYLINE | H01 | C | 08/02/2001 | RP DUE --- SINAGE MISSING | LES | LES | | H01 | C | 884720 |
BROOKDALE SKYLINE | H02 | C | 02/15/2001 | RP 2-00 --- PHONE INOP. | LES | LES | | H02 | C | 884714 |
BROOKDALE SKYLINE | H01 | C | 08/02/2000 | rp 2-00 OTIS LOCKBOX | LES | LES | | H01 | C | 884632 |
BROOKDALE SKYLINE | H02 | P | 02/15/2000 | RP EXPIRED (9-98)--OTIS | TOM | TOM | | H02 | P | 884706 |
BROOKDALE SKYLINE | H01 | C | 08/20/1999 | RP 9-98--OTIS--INSTALL 94 | TOM | TOM | | H01 | C | 884698 |
BROOKDALE SKYLINE | H02 | C | 02/25/1999 | | RUSS | RUSS | | H02 | C | 884625 |
BROOKDALE SKYLINE | H01 | P | 08/19/1998 | water in pit, rp over due | DAVEL | DAVEL | | H01 | P | 884618 |
BROOKDALE SKYLINE | H02 | C | 02/25/1998 | | RUSS | RUSS | | H02 | C | 884611 |
BROOKDALE SKYLINE | H01 | C | 08/19/1997 | d.l. | RUSS | RUSS | | H01 | C | 884690 |
BROOKDALE SKYLINE | H02 | C | 02/27/1997 | | RUSS | RUSS | | H02 | C | 884683 |
BROOKDALE SKYLINE | H01 | C | 08/12/1996 | rp2-96 | RUSS | RUSS | | H01 | C | 884676 |
BROOKDALE SKYLINE | H02 | R | 02/13/1996 | rp exp. second time | RUSS | RUSS | | H02 | R | 884667 |
BROOKDALE SKYLINE | H01 | P | 08/14/1995 | shaft vent cover,rp7-94 | RUSS | RUSS | | H01 | P | 884661 |
BROOKDALE SKYLINE | H02 | P | 02/28/1995 | | RUSS | RUSS | | H02 | P | 884648 |
BROOKDALE SKYLINE | H01 | C | 08/05/1994 | INIT INSP, PMT ISSD, ORDER: VENT SHFT, SMOKE DECTS, PHONE, PIT LDR, WOOD MR COVER | BOBM | BOBM | | H01 | C | 884640 |