GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | C | 02/18/1997 | HTG SIGNED OFF 2-18-97 | JOE | JOE | | B= | C | 1076818 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 02/14/1997 | pending heat | JOE | JOE | | B= | P | 1076809 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 01/23/1997 | guardrail spacing at top & 2nd floor sw stair well west wing & top landing se well east wing---ok to occupy | JOE | JOE | | B= | P | 1076801 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 01/21/1997 | bld 8&10 | JOE | JOE | | B= | P | 1076793 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 10/10/1996 | | JOE | JOE | | BFR | P | 1076784 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 08/28/1996 | 2ND FLOOR DINING LOBBY,WEST WALLS OK | RICH | RICH | | BFR | P | 1076778 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 08/13/1996 | dinning lobby----pending fire damper insp---talked to super about damper insp | JOE | JOE | | BFR | P | 1076770 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 08/02/1996 | 3RD LEVEL WOOD FRAMING LOBBY LEVEL WEST WING OK | BLAKE | BLAKE | | BFR | P | 1076765 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/24/1996 | PARTIAL 2ND LEVEL-WOOD FRAMING-LOBBY LEVEL WEST WING OK | BLAKE | BLAKE | | BFR | P | 1076758 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/23/1996 | plaza level/ dining and bathrooms | DANF | DANF | | BFR | P | 1076751 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/17/1996 | west wing plaza | JOE | JOE | | BFR | P | 1076743 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 07/02/1996 | top level east wing | JOE | JOE | | BFR | P | 1076736 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 06/19/1996 | east wing lobby | JOE | JOE | | BFR | P | 1076729 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 06/11/1996 | 1st floor east wing | JOE | JOE | | BFR | P | 1076723 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 05/30/1996 | East wing & plaza levels: Firestop chases, seal horizontal penetrations from sprinkler lines | JOHNP | JOHNP | | BFR | P | 1076717 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 05/09/1996 | should have been B16 | JOE | JOE | | BFR | P | 1076710 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | R | 04/25/1996 | not ready-----should have been b16 | JOE | JOE | | BFR | R | 1076700 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B16 | P | 04/01/1996 | should have been B16 | JOE | JOE | | B16 | P | 1076693 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B16 | P | 03/25/1996 | should be a b16 | JOE | JOE | | B16 | P | 1076685 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | P | 02/01/1996 | found. insp. will be done by eng.----approved by building offical | JOE | JOE | | BFN | P | 1076668 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | P | 02/01/1996 | footer insp will be done by eng.---has been approved by building offical | JOE | JOE | | BFT | P | 1076677 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | P | 01/29/1996 | 9 line E to G | JOE | JOE | | BFN | P | 1076660 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | P | 01/26/1996 | four foot wall at elevator pad in west wing | CLOVIS | CLOVIS | | BFN | P | 1076652 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | P | 01/25/1996 | | JOE | JOE | | BFT | P | 1076646 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | P | 01/24/1996 | WEST WING FOOTINGS FOR STAIR WELLS | CLOVIS | CLOVIS | | BFT | P | 1076639 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | P | 01/24/1996 | EAST WING WALLS FOR ELEVATOR PADS | CLOVIS | CLOVIS | | BFN | P | 1076631 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | R | 01/23/1996 | not ready | JOE | JOE | | BFN | R | 1076623 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | P | 01/19/1996 | footer location marked on plans-----NEE ENG LETTER CHANGE DETAIL 2 SH 2.4 | JOE | JOE | | BFT | P | 1076615 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | P | 01/17/1996 | LOCATION MARKED ON PLANS | JOE | JOE | | BFT | P | 1076607 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | P | 01/16/1996 | CTL THOMPSON WILL PROVIDE INSPECTION REPORT | BLAKE | BLAKE | | BFT | P | 1076599 |
KENNY ELECTRIC SERVICE, INC. | E= | C | 02/12/1997 | | RON | RON | | E= | C | 1077660 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 12/10/1996 | dinning area 1st,+ 2nd fl. | RON | RON | | E= | P | 1077653 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 11/20/1996 | west dorm ok. | RON | RON | | E= | P | 1077645 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 11/19/1996 | east dorm ok. | RON | RON | | E= | P | 1077637 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 11/12/1996 | ceiling. | RON | RON | | ER | P | 1077629 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 10/31/1996 | ceilings dinning. | RON | RON | | ER | P | 1077624 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 10/25/1996 | BASEMENT HALLWAYS EAST&WEST-SECURE FIXTURES TO GRID | MIKEC | MIKEC | | ER | P | 1077618 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 09/16/1996 | walls. | RON | RON | | ER | P | 1077610 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 08/28/1996 | walls on 1st floor and kitchen | ARNOLD | ARNOLD | | ER | P | 1077596 |
KENNY ELECTRIC SERVICE, INC. | ES | P | 08/28/1996 | ok for metering by kenny elec 480 volt service | ARNOLD | ARNOLD | | ES | P | 1077603 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 08/13/1996 | 1st floor dinning hall, mid section, 3rd by east stairs vending machine area | TERRY | TERRY | | ER | P | 1077587 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/30/1996 | 3rd floor west wing | ARNOLD | ARNOLD | | ER | P | 1077579 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/19/1996 | 2nd floor west wing walls and first floor dining area | ARNOLD | ARNOLD | | ER | P | 1077572 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 06/26/1996 | 3rd floor east side, 1st floor on west side | TERRY | TERRY | | ER | P | 1077565 |
KENNY ELECTRIC SERVICE, INC. | ES | P | 06/18/1996 | inspected the building steel bond for the temp service is all | TERRY | TERRY | | ES | P | 1077558 |
KENNY ELECTRIC SERVICE, INC. | ES | P | 06/11/1996 | ok to re-energize temporary service for saturday 6-15-96 by kenny elec. | ARNOLD | ARNOLD | | ES | P | 1077550 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 05/31/1996 | CONFERENCE ON NEW SERVICE | RED | RED | | ER | P | 1077545 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 05/24/1996 | walls in bsmt and ruff for 1st and 2nd floor | ARNOLD | ARNOLD | | ER | P | 1077536 |
KENNY ELECTRIC SERVICE, INC. | ESL | P | 04/30/1996 | dining | ARNOLD | ARNOLD | | ESL | P | 1077528 |
KENNY ELECTRIC SERVICE, INC. | ESL | P | 04/25/1996 | | ARNOLD | ARNOLD | | ESL | P | 1077521 |
KENNY ELECTRIC SERVICE, INC. | ESL | P | 04/17/1996 | | ARNOLD | ARNOLD | | ESL | P | 1077514 |
KENNY ELECTRIC SERVICE, INC. | ESL | P | 04/16/1996 | | ARNOLD | ARNOLD | | ESL | P | 1077505 |
KENNY ELECTRIC SERVICE, INC. | EST | P | 04/09/1996 | ok to re-energize meters for temporary service after disconnects are relocated-by kenny elec.-saturday is the scheduled day for this | ARNOLD | ARNOLD | | EST | P | 1077497 |
KENNY ELECTRIC SERVICE, INC. | EUG | P | 04/05/1996 | | RON | RON | | EUG | P | 1077489 |
KENNY ELECTRIC SERVICE, INC. | EUG | P | 03/27/1996 | | ARNOLD | ARNOLD | | EUG | P | 1077483 |
KENNY ELECTRIC SERVICE, INC. | EUG | P | 03/13/1996 | west wing basement slab | TERRY | TERRY | | EUG | P | 1077473 |
KENNY ELECTRIC SERVICE, INC. | ESL | P | 03/07/1996 | east wing 1st floor slab | ARNOLD | ARNOLD | | ESL | P | 1077452 |
KENNY ELECTRIC SERVICE, INC. | EUG | P | 02/26/1996 | | ARNOLD | ARNOLD | | EUG | P | 1077445 |
KENNY ELECTRIC SERVICE, INC. | EUG | P | 02/22/1996 | EAST WING BSMT SLAB | GLENN | GLENN | | EUG | P | 1077437 |
KENNY ELECTRIC SERVICE, INC. | EUG | P | 02/15/1996 | east wing bsmt | ARNOLD | ARNOLD | | EUG | P | 1077430 |
KENNY ELECTRIC SERVICE, INC. | EUG | P | 02/14/1996 | deep under slab conduits | TERRY | TERRY | | EUG | P | 1077422 |
HEATING & PLUMBING ENGINEERS, INC | H= | C | 02/18/1997 | | JOHNW | JOHNW | | H= | C | 1076976 |
HEATING & PLUMBING ENGINEERS, INC | HD | C | 02/18/1997 | | JOHNW | JOHNW | | HD | C | 1076984 |
HEATING & PLUMBING ENGINEERS, INC | HI | C | 02/18/1997 | | JOHNW | JOHNW | | HI | C | 1076992 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 01/21/1997 | everything but kitchen ok for MECH TCO need to verify innerlocks on equipt. and need restraints on kitchen equipt. | JOHNW | JOHNW | | H= | P | 1076968 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 12/12/1996 | E & W wings complete, need kitchen | JIMV | JIMV | | H= | P | 1076959 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 11/01/1996 | ck fire dampers | JIMV | JIMV | | HD | P | 1076948 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 10/08/1996 | hood enclosures and grease shafts complete | JOHNW | JOHNW | | HD | P | 1076941 |
HEATING & PLUMBING ENGINEERS, INC | HC | C | 10/04/1996 | ok for meter | JOHNW | JOHNW | | HC | C | 1076933 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 09/24/1996 | protect top of hoods where they penitrate ceiling | JOHNW | JOHNW | | HD | P | 1076928 |
HEATING & PLUMBING ENGINEERS, INC | HD | R | 09/20/1996 | floor in kitchen was being painted recall when it is dry | JOHNW | JOHNW | | HD | R | 1076922 |
HEATING & PLUMBING ENGINEERS, INC | HI | P | 08/27/1996 | will need to replace unions with flanges at reg & ansil valve; weld stamp ( KK ) | JIMV | JIMV | | HI | P | 1076914 |
HEATING & PLUMBING ENGINEERS, INC | HI | P | 08/02/1996 | west wing to boiler room ok/need welders I.D. stamp before final | JOHNW | JOHNW | | HI | P | 1076905 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 07/23/1996 | grease duct comp/1st level duct comp in kitchen / 2nd floor rough duct comp except for firedamper framing | JOHNW | JOHNW | | H= | P | 1076897 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 07/16/1996 | chilled water lines thru kitchen area from east to west wings | JOHNW | JOHNW | | H= | P | 1076890 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 07/11/1996 | 3rd level duct ok | JOHNW | JOHNW | | HD | P | 1076874 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 07/11/1996 | hot water lines ok | JOHNW | JOHNW | | HD | P | 1076883 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 06/25/1996 | exhaust duct in attic east wing ok | JOHNW | JOHNW | | HD | P | 1076866 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 06/19/1996 | 1st & 2nd floors above ceiling rough inc. exhaust ok in rooms | JOHNW | JOHNW | | HD | P | 1076858 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 05/31/1996 | consultation on grease duct and shaft | JOHNW | JOHNW | | HD | P | 1076850 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 05/30/1996 | need to talk to contractor about the grease duct wrap being used | JOHNW | JOHNW | | HD | P | 1076842 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 05/20/1996 | chilled water lines in the east and west wings | JOHNW | JOHNW | | HD | P | 1076834 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 04/23/1996 | chiller room consultation | JOHNW | JOHNW | | HD | P | 1076826 |
HEATING & PLUMBING ENGINEERS, INC | P= | C | 01/15/1997 | KITCHEN | DAVEL | DAVEL | | P= | C | 1077414 |
HEATING & PLUMBING ENGINEERS, INC | P= | P | 12/04/1996 | W. wing complete | JIMV | JIMV | | P= | P | 1077406 |
HEATING & PLUMBING ENGINEERS, INC | P= | P | 12/03/1996 | top 3 floors E. wing | JIMV | JIMV | | P= | P | 1077399 |
HEATING & PLUMBING ENGINEERS, INC | PTO | C | 08/14/1996 | main level,west end men/womens restrooms next to stairwell | LYNNIE | LYNNIE | | PTO | C | 1077391 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 08/08/1996 | room #113,115,117,118,202 | LYNNIE | LYNNIE | | PTO | P | 1077383 |
HEATING & PLUMBING ENGINEERS, INC | PTO | R | 08/07/1996 | 4:05 No plumbers on job, restrooms by kitchen no test | KYE | KYE | | PTO | R | 1077375 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 08/02/1996 | roof drains on the west dorms to the north in the stairwell from the roof to the tie-ins in the basement static H2O test ok | BILL | BILL | | PRD | P | 1077368 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 07/31/1996 | west wing of the dorms between the columns of A.6 and C from grids 9 and 10 from the base floor the the roof ok static test, and the two roof drains on the south end of the west dorms on the third floor between columns G and H and grids 8 and 10 ok | BILL | BILL | | PRD | P | 1077344 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/31/1996 | in the dining area small bathrooms numbers 142 and 145 the water pipe holding at 100# | BILL | BILL | | PTO | P | 1077352 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/31/1996 | west wing dorms on the north end of the building n lines A.6 to C and between 9 and 10 the domestic waste and water ok,,static on waste and 120# on copper | BILL | BILL | | PTO | P | 1077360 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/24/1996 | first floor dining west wing big bathrooms with floor drains and the floor drains for the bathrooms directly above ok | BILL | BILL | | PTO | P | 1077327 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/24/1996 | third floor domestic water C.8 and G on column lines 8 through 10 ok with 120# test | BILL | BILL | | PTO | P | 1077335 |
HEATING & PLUMBING ENGINEERS, INC | PGI | P | 07/18/1996 | all of the branches in the kitchen area except the two 1 1/4" stubs to the kitchen equipment ok// 200# test | BILL | BILL | | PGI | P | 1077319 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/12/1996 | domestic waste and vent on the west wing housing on the second and third floors between column lines C.8 and G and on grid lines 8 to 10//h2o test static ok | BILL | BILL | | PTO | P | 1077311 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/10/1996 | domestic water from the east bathrooms to where the 3" drops into the meter room but not through the cored wall and to the west end bathrooms but no rough-in in the bathrooms yet just through the cored wall and the 3" future on line 8 along B.3, all at 110 line pressure,,all the stubs in the kitchen area are tested to the ball valves on the main line trunks,,will recall when kitchen and west bathrooms are roughed in | BILL | BILL | | PTO | P | 1077303 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 07/03/1996 | roof drain in the vestibule numbered 106 on grid lines 16 and 17 on column line D ok | BILL | BILL | | PRD | P | 1077279 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/03/1996 | bathroom groups numbered 102,103,142,and 145 on the main level ok on the waste and vent but no water pipe at this time, | BILL | BILL | | PTO | P | 1077287 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/03/1996 | domestic water lines in the west wing between grid lines 8 and 10 on column lines C.8 to H on the basement,1st and 2and floors only, static 100# test | BILL | BILL | | PTO | P | 1077295 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 06/27/1996 | 5 storms in the large round area to the south of the dining room// both of the drains in the entry on the north and two drains on each end at the bathrooms on the east and the west end on the second floor over the kitchen area ok | BILL | BILL | | PRD | P | 1077271 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 06/25/1996 | roof drains and scuppers on the third floor on the east wing to the south between column lines G and H on grid lines 19.2 and 20.6 ok | BILL | BILL | | PRD | P | 1077255 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 06/25/1996 | third floor water mains and total water pipe pressured on the east wing to 110 hydrostatic ok,,mechanical room heaters not set yet and will recall,, water pipe between column lines A to H on grid lines 19 to 21 ok/// | BILL | BILL | | PTO | P | 1077263 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 06/13/1996 | sanitary waste and vent from basement to the revent on the second floor between H and C.8 between lines 8 and 10 ok | BILL | BILL | | PTO | P | 1077247 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 06/13/1996 | roof drains above ground grid lines H and C.8 between 8 and 10 from the basement to the roof line ok | BILL | BILL | | PRD | P | 1077240 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 06/12/1996 | roof drains second floor to third floor between B.9 to A.5 on lines 19 and 21 ok | BILL | BILL | | PRD | P | 1077224 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 06/12/1996 | domestic water on the third floor from G to C.8 between lines 19 and 21 ok in the bathrooms but no mains yet in the heat chases over head | BILL | BILL | | PTO | P | 1077232 |
HEATING & PLUMBING ENGINEERS, INC | PTO | R | 06/11/1996 | cancelled per ann at 930 hours | BILL | BILL | | PTO | R | 1077216 |
HEATING & PLUMBING ENGINEERS, INC | PRD | R | 06/11/1996 | cancelled per ann at 930 hours | BILL | BILL | | PRD | R | 1077208 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 06/07/1996 | roof drains on grid line C on column's 17,15,14, 12 with 8 total roof drains,,and sanitary vents on B column and grid lines 17,14,11.2,,, relocated sanitary vent from C.5 on grid 13 to B.5 on grid 17 | BILL | BILL | | PTO | P | 1077201 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 05/30/1996 | sanitary waste and vent on the third floor of the east wing between column lines 19 and 21 and grid lines A to H ok but no water lines yet | BILL | BILL | | PTO | P | 1077195 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 05/28/1996 | sanitary vents in the kitchen area at grid line 12 on column line B and grid lines 12.5 and 14.5 at column line C | BILL | BILL | | PTO | P | 1077186 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 05/28/1996 | risers on grid line 17 on column line C and grid line 15 on column line B including the 2" to the east side of the mezzinene | BILL | BILL | | PRD | P | 1077179 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 05/24/1996 | ROOF DRAINS ON GRID LINES 12, 14, 15 ON COLUMN LINE C OK AND GRID LINE 14 ON COLUMN LINE B WITH A 2" BRANCH TO A AREA DRAIN IN THE MEZZANINE OK | BILL | BILL | | PRD | P | 1077163 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 05/24/1996 | SANITARY ON COLUMN LINE A SOUTH TO B GRID LINE 13 EAST TO 17 BUT NO WATER PIPE YET | BILL | BILL | | PTO | P | 1077172 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 05/23/1996 | water lines in the kitchen area in the block walls tested with air prior to the installation ok | BILL | BILL | | PTO | P | 1077157 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 05/22/1996 | sanitary in the west kitchen on grid lines A.7 to A.2 and on lines 11.2 to 12.5 | BILL | BILL | | PTO | P | 1077149 |
HEATING & PLUMBING ENGINEERS, INC | PTO | R | 05/21/1996 | CANCELED AT 3:33 PER CONTRACTOR | GUEST | GUEST | | PTO | R | 1077142 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 05/10/1996 | 100# test//column lines H to C.8 and grid lines 19 to 21 on the basement, 1st, and 2and floors ok | BILL | BILL | | PTO | P | 1077136 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 05/02/1996 | the large bathrooms on the east end of the visitors center, the drinking fountain and the vent off the floor sink in the cafe ok///no water pipe yet | BILL | BILL | | PTO | P | 1077128 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 05/01/1996 | CHILLER ROOM UG SAN AND STORM BETWEEN LINES A AND C AND GRID LINES 9 AND 10 AND THE KITCHEN GREASE LINES UG BETWEEN A AND A.5 AND GRID LINES 11.5 AND 14 OK TO COVER | BILL | BILL | | PB | P | 1077118 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 04/30/1996 | lines H to F and between grid lines 19 and 21 on the 1st and 2and floors ok, sanitary and storm | BILL | BILL | | PTO | P | 1077112 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 04/29/1996 | east wing//sanitary between lines 19 and 21 and grid lines E thru C.8 1st and 2and level ok and sanitary and storm on lines B.3 thru A.5 and grid lines 19 thru 20 1st level ok | BILL | BILL | | PTO | P | 1077104 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 04/26/1996 | all the sanitary and storms in the kitchen area except all tne piping north of grid line A.5 | BILL | BILL | | PB | P | 1077096 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 04/22/1996 | underground sanitary from grid line 11.5 to 16 and column lines A.8 to B and C to B and C to A.5///and grease lines underground on grid lines 12.5 colunmn C to B, and grid line B.6 between 12.5 and 11 and grid line B.8 between 12.5 and 14.5 and grid line B between 12.5 and 11.5 ok to cover | BILL | BILL | | PB | P | 1077087 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 04/15/1996 | the sanitary,grease,and storm within the column lines of C and D and grid lines of 9.8 and 12 ok to cover | BILL | BILL | | PB | P | 1077081 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 04/11/1996 | 6" stubs at column line 12 to column line 14 and from grid line C to grid line D and the branches within this perameter | BILL | BILL | | PRD | P | 1077073 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 04/05/1996 | dining area on grid lines 13 to 17 and from column line D to the radius in the vestibule | BILL | BILL | | PRD | P | 1077063 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 04/04/1996 | between grid lines 15 and 19.2 and column lines D to B.3 ok to cover | BILL | BILL | | PRD | P | 1077053 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 04/04/1996 | between grid lines 17 and 20 and column lines A and D ok to cover | BILL | BILL | | PB | P | 1077043 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 03/18/1996 | the sanitary on the east wing between the columns 19- to 20 and between grid lines a and c ok | BILL | BILL | | PB | P | 1077029 |
HEATING & PLUMBING ENGINEERS, INC | PRD | P | 03/18/1996 | the roof drains on the east wing between the columns 19 and 20 and grid lines a and c ok | BILL | BILL | | PRD | P | 1077036 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 03/04/1996 | see the card | BILL | BILL | | PB | P | 1077021 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 03/01/1996 | east branches off the west trunk in the dorm area up to e-line ok | BILL | BILL | | PB | P | 1077013 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 02/16/1996 | E. wing complete | JIMV | JIMV | | PB | P | 1077006 |
HEATING & PLUMBING ENGINEERS, INC | PB | P | 02/13/1996 | east wing housing trunk line only | ELDON | ELDON | | PB | P | 1076999 |