CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/02/2024 | PERFORMED EXTERNAL INSPECTION ON ESCALATOR -- / COMBPLATES WITH MISSING TEETH AT BOTTOM END NEED REPAIRED/REPLACED (Receipt #2020935) | DUSTINS | DUSTINS | | H02 | C | 7957700 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H07 | C | 11/21/2023 | WITNESSED ANNUAL TEST W/ ELEVATOR TECHNICIANS | BENH | BENH | | H07 | C | 7925394 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H05 | C | 07/24/2023 | ESCALATOR DOWN FOR REPAIRS AT TIME OF INSPECTION / ANNUAL WITNESS TESTING TO BE PERFORMED BEFORE ESCALATOR CAN BE RETURNED TO NORMAL SERVICE / RBD NOTE: CREATE H01 WHEN H07 IS PERFORMED | DUSTINS | DUSTINS | | H05 | C | 7805588 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H05 | C | 03/30/2023 | ESCALATOR WAS SHUTDOWN DUE TO ITEMS FROM PREVIOUS INSPECTION REPORT NOT BEING ADDRESSED. | ROBERTV | ROBERTV | | H05 | C | 7703090 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/13/2023 | SCHINDLER ESCALATOR - LEFT HANDRAIL IS SPLIT 10" ON SIDE (PARALLEL TO NEWELL). SECURE LOWER RIGHT INNER DECK PANEL COMPLETELY. LEFT TURN AROUND ROLLERS SQUEALING UPPER AND LOWER ENDS. LOWER COMB PLATES MISSING TEETH NEED TO BE REPLACED....... 60 DAYS TO ADDRESS. | ROBERTV | ROBERTV | | H02 | C | 7634732 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/26/2022 | WITNESSED AT H01 -- SEE H07 COMMENTS (Receipt #1886322) | ROBERTV | ROBERTV | | H01 | C | 7460774 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H07 | C | 07/26/2022 | WITNESSED ESCALATOR STEP INDEX AND SAFETY TESTING W/ ELEVATOR TECHNICIANS - HANDRAIL DRIVE CHAIN NEEDS TO BE ADJUSTED OR REPLACED.............. 30 DAYS TO ADDRESS. DUE TO THE ONGOING ISSUES WITH SLACK AND POOR CONDITION OF THE HANDRAIL DRIVE CHAINS, EXAMINATIONS AND/OR ADJUSTMENTS SHALL TAKE PLACE IN INTERVALS NO MORE THAN 6 MONTHS FROM HEREON AND SHALL BE DOCUMENTED IN THE ESCALATOR MAINTENANCE AND REPAIR RECORDS ONSITE. FAILURE TO PROVIDE DOCUMENTATION WILL RESULT IN THE ESCALATOR BEING REMOVED FROM SERVICE. (Updated 10/10/2022 RV - MCP noted in the for Handrail Drive Chain Adjustment) | ROBERTV | ROBERTV | | H07 | C | 7460769 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/21/2022 | SCHINDLER ESCALATOR W/ ELEV TECH SERVICE - ESCALATOR DOWN FOR REPAIRS AT TIME OF INSPECTION..... (NOTE: ESCALATOR CLEAN DOWN NEEDS TO BE PERFORMED BY WITNESS TESTING IN 7/2022 FOR ESCALATOR TO REMAIN IN SERVICE. NO EXTENSIONS WILL BE PERMITTED) | ROBERTV | ROBERTV | | H02 | C | 7246009 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/26/2021 | SCHINDLER ESCALATOR - ENTIRE ESCALATOR CLEAN DOWN NEEDS PERFORMED BY 7/2022 TO REMAIN IN SERVICE. NEED OIL / GREASE - REPAIR - REPLACEMENT - ADJUSTMENT LOGS ONSITE. (NOTE: HANDRAIL DRIVE CHAIN WAS ADJUSTED TO PASS INSPECTION, NEEDS MORE ATTENTION THAN ONCE A YEAR) (BRAKE TORQUE 21-65 FT/LBS, ACTUAL 35 FT/LBS) (Receipt #1793321) | ROBERTV | ROBERTV | | H01 | C | 7049586 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/26/2021 | SCHINDLER ESCALATOR - NEED TO SECURE UPPER RIGHT AND LOWER LEFT DECK END CAPS (CURRENT HARDWARE IS STRIPPED). ESCALATOR STILL NEEDS CLEANED DOWN TO MEET CODE COMPLIANCE. | ROBERTV | ROBERTV | | H02 | C | 6848437 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/16/2020 | ESCALATOR WAS RETURNED TO SERVICE AFTER REPAIRS TO HANDRAIL DRIVE CHAIN AND HANDRAIL INLET DEVICE. - UNIT STILL NEEDS CLEAN DOWN PERFORMED THAT WAS NEVER COMPLETED. | ROBERTV | ROBERTV | | HE16 | C | 6743644 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H05 | C | 09/01/2020 | ESCALATOR WAS RED TAGGED AND REMOVED FROM SERVICE DUE TO ITEMS AS LISTED... LOWER LEFT HANDRAIL INLET DEVICE IS INOPERABLE. HANDRAIL DRIVE CHAIN IS STRETCHED AND ROUGED DUE TO LACK OF MAINTENANCE AND LUBRICATION (NEEDS REPLACED). ESCALATOR CLEAN DOWN HAS NOT BEEN PERFORMED TO MEET CODE COMPLIANCE. | ROBERTV | ROBERTV | | H05 | C | 6692235 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/22/2020 | SCHINDLER ESCALATOR - UNIT WAS REMOVED FROM SERVICE DUE TO INOPERABLE LOWER LEFT HANDRAIL INLET SWITCH......... UNIT MUST NOT BE RETURNED TO SERVICE UNTIL FIXED. ALSO, ITEMS FROM ANNUAL SAFETY TESTING HAVE YET TO BE ADDRESSED: --- ESCALATOR CLEAN DOWN HAS NOT BEEN PERFORMED TO MEET CODE COMPLIANCE. HANDRAIL DRIVE CHAIN IS STRETCHED AND ROUGED DUE TO LACK OF MAINTENANCE AND LUBRICATION (NEEDS REPLACED). MULTIPLE YELLOW DEMARCATION STEP TREADWAY INSERTS ARE BROKEN AND NEED REPLACED. MULTIPLE STEPS ARE HITTING COMPLATES AND WALK ON PLATES AT TOP AND BOTTOM. SECURE LOWER LEFT DECK END NEWEL BASE............. ALL ITEMS NEED TO BE COMPLETED WITHIN 30 DAYS TO AVOID SERVICE INTERRUPTION. (Receipt #1698109) | ROBERTV | ROBERTV | | H01 | C | 6646732 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 04/08/2020 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX INSPECTION W/ OTIS - ESCALATOR CLEAN DOWN HAS NOT BEEN PERFORMED TO MEET CODE COMPLIANCE. HANDRAIL DRIVE CHAIN IS STRETCHED AND ROUGED DUE TO LACK OF MAINTENANCE AND LUBRICATION (NEEDS REPLACED). MULTIPLE YELLOW DEMARCATION STEP TREADWAY INSERTS ARE BROKEN AND NEED REPLACED. MULTIPLE STEPS ARE HITTING COMPLATES AND WALK ON PLATES AT TOP AND BOTTOM. SECURE LOWER LEFT DECK END NEWEL BASE..........(NOTE: BRAKE TORQUE MINIMUM 21 FT/LBS - ACTUAL 54 FT/LBS) | ROBERTV | ROBERTV | | HE16 | C | 6534496 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/13/2020 | SCHINDLER ESCALATOR - DETERMINED CLEAN DOWNS WERE NOT PERFORMED AFTER ESCALATOR TRUSS AND PAN INSPECTION. LOWER LEFT DECK END PLATE STILL NOT SECURED (ATTACHING SCREW IS STRIPPED). WITNESSED ANNUAL INSPECTIONS DUE 3/31/2020. | ROBERTV | ROBERTV | | H02 | C | 6450827 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/17/2019 | SCHINDLER ESCALATOR - LOWER LEFT DECK PLATE IS STILL UNSECURED, THIS WAS NOTED TO BE COMPLETED BY OTIS ON THE SPREAD SHEET SUMMARY. INTERNAL CLEANDOWN NEEDS PERFORMED BY NEXT ANNUAL 11/2019 (Receipt #1614801) | ROBERTV | ROBERTV | | H01 | C | 6266410 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/31/2019 | SCHINDLER ESCALTOR - LOWER LEFT DECK END PLATE HAS NOW BECOME UNSECURED, THIS NEEDS TO BE REPAIRS IN A PERMANENT MANNER........ INTERNAL CLEAN DOWN NEEDS TO BE PERFORMED BEFORE NEXT ANNUAL TESTING 11/2019 | ROBERTV | ROBERTV | | H02 | C | 6093178 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/05/2018 | SCHINDLER ESCALATOR - WITNESSED ANNUAL STEP INDEX AND SAFETY TESTING W/ OTIS. ESCALATOR INTERNALS NEED TO BE CLEANED DOWN IT THEIR ENTIRETY. THIS NEEDS TO BE PERFORMED BEFORE NEXT ANNUAL INSPECTION 11/5/2019. (NOTE: BRAKE TORQUE 43 FT/LBS ----- 21-63 FT/LBS REQUIRED) | ROBERTV | ROBERTV | | HE16 | C | 6016253 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/10/2018 | SCHINDLER ESCALATOR - NEED REPAIR/ADJUSTMENTS/CALLBACK LOGS IN ESCALATOR MAINTENANCE CONTROL PROGRAM | ROBERTV | ROBERTV | | H01 | C | 5897457 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/08/2018 | ITEMS LISTED ON INSPECTION REPORT DATED 10/2017 AND PRIOR: ------ UNKNOWN IF ESCALATOR PITS HAVE BEEN CLEANED, LOWER LEFT HANDRAIL END CAP NEED SECURED | ROBERTV | ROBERTV | | H02 | C | 5731091 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/17/2017 | WITNESSED ANNUAL SAFETY INSPECTION AND STEP INDEX TESTING WITH OTIS - ESCALATOR PITS NEED CLEANED | ROBERTV | ROBERTV | | HE16 | C | 5657859 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/07/2017 | SCHINDLER W/ OTIS SERVICE -- SEVERAL YELLOW DEMARCATION TREADWAY AND RISER INSERTS ARE BROKEN AND NEED REPLACED (2ND NOTICE), NEED ESCALATOR MAINTENANCE CONTROL PROGRAM ONSITE (2ND NOTICE). ITEMS MUST BE ADDRESSED BY ANNUAL TESTING 10/2017 (Receipt #1437203) | ROBERTV | ROBERTV | | H01 | C | 5556733 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/19/2017 | SCHINDLER - SEVERAL YELLOW TREADWAY AND RISER INSERTS BROKEN AND NEED REPLACED. NEED ESCALATOR MAINTENANCE CONTROL PROGRAM ONSITE. | ROBERTV | ROBERTV | | H02 | C | 5392502 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/28/2016 | PERFORMED ANNUAL STEP INDEX AND SAFETY TESTING W/ OTIS -- (NO ISSUES) | ROBERTV | ROBERTV | | HE16 | C | 5330247 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/15/2016 | SCHINDLER, OTIS SERVICE (Receipt #1342042) | ERIC | ERIC | | H01 | C | 5245808 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/11/2016 | SCHINDLER W/ OTIS SERVICE NEED MAINTENANCE CONTROL PROGRAM DOCUMENTS ONSITE NEXT INSPECTION. | ROBERTV | ROBERTV | | H02 | C | 5113178 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/23/2015 | STEP / SKIRT INDEXING HAS BEEN COMPLETED, STILL NEED REMAINING ITEMS ADDRESSED. | ROBERTV | ROBERTV | | HE16 | C | 5085827 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/16/2015 | WITNESSED ANNUAL INSPECTION AND TESTING W/ OTIS -- DEMARCATION LIGHTS ARE STILL NOT WORKING AND HAVE BEEN NOTED MULTIPLE TIMES, REPAIRS AND STEP INDEXING NEED TO BE COMPLETED BY 12/31/2015 | ROBERTV | ROBERTV | | HE16 | C | 5079924 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/07/2015 | NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2015, NEED SKIRT BRUSHES INSTALLED, BOTH HANDRAILS ARE DAMAGED AND MUST BE REPLACED, DEMARCATION LIGHTS NOT WORKING (Receipt #1272557) | ERIC | ERIC | | H01 | C | 4987378 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/08/2015 | SCHINDLER, OTIS SERVICE. INSTALL SKIRT BRUSHES, RIGHT HANDRAIL NEEDS REPLACED, DEMARCATION LIGHTS NOT WORKING, CLEAN DOWN | ERIC | ERIC | | H02 | C | 4882385 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 12/31/2014 | WITNESSED ANNUAL SAFETY INSPECTION AND INDEX TESTING. INSTALL SKIRT BRUSHES, RIGHT HANDRAIL NEEDS REPLACED, DEMARCATION LIGHTS NOT WORKING, CLEAN DOWN | ERIC | ERIC | | HE16 | C | 4879229 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/01/2014 | SCHINDLER. OTIS SERVICE. MUST HAVE SKIRT BRUSHES INSTALLED, NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2014 (Receipt #1204937) | ERIC | ERIC | | H01 | C | 4769896 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/16/2014 | SCHINDLER. OTIS SERVICE. INSTALL SKIRT BRUSHES, NEED END FILLER PIECES ON COMB PLATES, NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2014 | ERIC | ERIC | | H02 | C | 4673529 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/10/2013 | SCHINDLER, OTIS SERVICE, INSTALL SKIRT BRUSHES THAT WERE REMOVED FOR REPAIRS AND EXTEND THEM TO THE COMB PLATES, MISSING COMB PLACE END FILLER PIECES AND DEMARCATION LIGHTS NOT WORKING (Receipt #1141026) | ERIC | ERIC | | H01 | C | 4560595 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 04/26/2013 | INDEX TESTING COMPLETE | ERIC | ERIC | | HE16 | C | 4513258 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 04/19/2013 | ANNUAL INSPECTION-REPAIR BOTTOM KEYED START SWITCH, INSTALL SKIRT BRUSHES AND EXTEND THEM TO THE COMB PLATES, MISSING END FILLER PIECES ON COMB PLATES, DEMARCATION LIGHTS NOT WORKING, INSTALL DECK BARRICADES IN PROPER LOCATIONS FOR BOTH | ERIC | ERIC | | HE16 | C | 4510860 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/22/2013 | SCHINDLER. OTIS SERVICE, INSTALL LOWER DECK BARRICADES IN PROPER LOCATION, EXTEND SKIRT BRUSHES TO COMB PLATES, NEED ANNUAL WITNESSED INSPECTION AND INDEX TESTING | ERIC | ERIC | | H02 | C | 4458349 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/02/2012 | SCHINDLER. OTIS SERVICE. INSTALL LOWER DECK BARRICADES IN PROPER LOCATION, GAPS IN GLASS PANELS EXCEED 1/4", EXTEND SKIRT BRUSHES TO COMB PLATES, NEED INDEX TESTING AND ANNUAL INSPECTION FOR 2012 (Receipt #1056567) | ERIC | ERIC | | H01 | C | 4335333 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/09/2012 | SCHINDLER. OTIS SERVICE. MANY EXCESSIVELY WORN STEP TREADS, NEED DECK BARRICADES INSTALLED, EXTEND SKIRT BRUSHES TO COMB PLATES | ERIC | ERIC | | H02 | C | 4258365 |
COYOTE MANAGEMENT LP | HE16 | C | 08/22/2011 | ANNUAL INSPECTION AND INDEX TESTING COMPLETE | ERIC | ERIC | | HE16 | C | 4196541 |
COYOTE MANAGEMENT LP | H01 | C | 07/13/2011 | SEC. OTIS SERVICE. NEED LOWER DECK BARRICADES, DEMARCATION LIGHTS OUT, SKIRT BRUSHES MUST EXTEND TO COMB PLATES, ESCALATOR (Receipt #986155) | ERIC | ERIC | | H01 | C | 4177270 |
GENERAL GROWTH | H02 | C | 01/10/2011 | SCHINDLER. MKE SERVICE. NEED ANNUAL INDEX TESTING AND INSPECTION, DECK BARRICADES NEED TO BE INSTALLED IN PROPER LOCATION, SKIRT BRUSHES NEED TO EXTEND TO COMB TEETH | ERIC | ERIC | | H02 | C | 4096694 |
GENERAL GROWTH | HE16 | C | 01/10/2011 | WITNESSED ANNUAL TEAR DOWN INSPECTION AND INDEX TESTING. INDEX TESTS OK. NEED UPPER START SWITCH, INSTALL DECK BARRICADES IN PROPER LOCATIONS, SKIRT BRUSHES NEED TO EXTEND TO COMB PLATES, MANY STEPS NEED TO BE REPLACED DUE TO EXCESSIVE WEAR | ERIC | ERIC | | HE16 | C | 4106354 |
GENERAL GROWTH | H01 | C | 07/16/2010 | NEED ANNUAL INSPECTION AND INDEX TESTING (Receipt #920621) | ERIC | ERIC | | H01 | C | 4010861 |
GENERAL GROWTH | H02 | C | 01/07/2010 | SCHINDLER, KONE SERVICE | ERIC | ERIC | | H02 | C | 3930034 |
GENERAL GROWTH | HE16 | C | 12/15/2009 | WITNESSED INDEX TESTING | ERIC | ERIC | | HE16 | C | 3922961 |
GENERAL GROWTH | H01 | C | 07/15/2009 | SCHINDLER. KONE SERVICE, MANY EXCESSIVLY WORN TREADS, DEMARCATION LIGHTS OUT, NEED PERFORMANCE INDEX TEST (Receipt #867319) | ERIC | ERIC | | H01 | C | 3858765 |
GENERAL GROWTH | HE16 | C | 01/29/2009 | WITNESSED ANNUAL TEAR DOWN INSPECTION AND SAFETY TESTS | ERIC | ERIC | | HE16 | C | 3796181 |
GENERAL GROWTH | H02 | C | 01/29/2009 | SCHINDLER. NEED BOTTOM BARRICADES AND DEMARCATION LIGHTS OUT AT BOTH LANDINGS | ERIC | ERIC | | H02 | C | 3796179 |
GENERAL GROWTH | H01 | C | 07/31/2008 | SCHINDLER --- NEED BARRICADE BOTTOM CENTER AND OUTSIDE BARRICADE NEEDS TO BE MOVED (Receipt #819293) | LES | LES | | H01 | C | 3717827 |
GENERAL GROWTH | H02 | C | 01/29/2008 | SCHINDLER--NEED BARRICADE CENTER BOTTOM AND MOVE OUTSIDE BARRICADES UP | JOHNW | JOHNW | | H02 | C | 1468603 |
GENERAL GROWTH | H01 | C | 08/28/2007 | SCHINDLER--MISSING BARRICADES AT BOTTOM AND OUTSIDE LOWER ARE TOO LOW--SOME OF THE TREADS ARE WORN IN EXCESS OF THE SPECS | JOHNW | JOHNW | | H01 | C | 1468595 |
GENERAL GROWTH | H02 | C | 01/31/2007 | SCHINDLER--MISSING BARRICADES INSIDE LOWER AND OUTSIDE ARE TOO LOW--SOME OF THE TREADS ARE WORN AND EXCEED SPECS.--HANDRAIL SPEED SENSORS NOT WORKING | JOHNW | JOHNW | | H02 | C | 1468587 |
GENERAL GROWTH | H01 | C | 07/31/2006 | SCHINDLER-- 2 BROKEN TREAD--NEED THE BARICADES UP ON THE LOW DECK | JOHNW | JOHNW | | H01 | C | 1468581 |
GENERAL GROWTH | H02 | C | 01/31/2006 | SCHINDLER--50636-1--1 BROKEN TRED --DEMARCATION LIGHT TOP AND BOTTOM OUT | JOHNW | JOHNW | | H02 | C | 1468574 |
GENERAL GROWTH | H01 | C | 07/25/2005 | SCHINDLER--1 BROKEN COMB TOP--2 BROKEN TREDS--DEMARCATION LIGHTS OUT AT TOP AND BOTTOM | JOHNW | JOHNW | | H01 | C | 1468566 |
GENERAL GROWTH | H02 | C | 01/31/2005 | #50636-1 / SCHINDLER--MISSING SCREWS--1 BROKEN TREAD--BROKEN TOOTH ON COMB PLATE | JOHNW | JOHNW | | H02 | C | 1468559 |
GENERAL GROWTH | H01 | C | 07/07/2004 | REPLACE SCREWS IN SKIRTING | LES | LES | | H01 | C | 1468550 |
GENERAL GROWTH | H02 | C | 01/26/2004 | SCHINDLER | LES | LES | | H02 | C | 1468543 |
GENERAL GROWTH | H01 | C | 07/11/2003 | | LES | LES | | H01 | C | 1468534 |
GENERAL GROWTH | H02 | C | 01/30/2003 | TOOTH MISSING TOP LANDING | LES | LES | | H02 | C | 1468526 |
GENERAL GROWTH | H01 | C | 07/19/2002 | | LES | LES | | H01 | C | 1468518 |
GENERAL GROWTH | H02 | C | 01/24/2002 | REPAIR DEMARCATION LIGHTS | LES | LES | | H02 | C | 1468510 |
GENERAL GROWTH | H01 | C | 07/27/2001 | | LES | LES | | H01 | C | 1468501 |
GENERAL GROWTH | H02 | C | 01/26/2001 | | LES | LES | | H02 | C | 1468493 |
GENERAL GROWTH | H01 | C | 07/25/2000 | | LES | LES | | H01 | C | 1468485 |
GENERAL GROWTH | H02 | C | 01/31/2000 | | TOM | TOM | | H02 | C | 1468478 |
GENERAL GROWTH | H01 | C | 07/13/1999 | | RUSS | RUSS | | H01 | C | 1468462 |
GENERAL GROWTH | H02 | C | 01/20/1999 | | RUSS | RUSS | | H02 | C | 1468454 |
GENERAL GROWTH | H01 | C | 07/21/1998 | INITIAL INSPECTION | RUSS | RUSS | | H01 | C | 1468469 |