THE DEER CREEK CORPORATION | B= | C | 05/05/1999 | | TOM | TOM | | B= | C | 1517698 |
THE DEER CREEK CORPORATION | BFR | P | 02/25/1999 | BALANCE OF FRAMING OK--NEED GAS INSP. | TOM | TOM | | BFR | P | 1517671 |
THE DEER CREEK CORPORATION | BFR | P | 02/22/1999 | 3 DRYWALL LIDS NOT FRAMED YET--NEED GAS INSP--ALL OTHER INT. FRAMING OK | TOM | TOM | | BFR | P | 1517692 |
THE DEER CREEK CORPORATION | BFR | P | 01/29/1999 | NOTCHED STUD & STRUCTURAL ENG ON FILE--PARAPET & GABLED ROOF OK--NORTH INT WALL SECTION MARKED & SIGNED ON PLANS OK PEND E=R & P=R | TOM | TOM | | BFR | P | 1517683 |
THE DEER CREEK CORPORATION | BFN | C | 12/18/1998 | | MIKE | MIKE | | BFN | C | 1517658 |
THE DEER CREEK CORPORATION | BFT | C | 12/18/1998 | Rec'd caisson log from Goodson & Assciates(33077) | MIKE | MIKE | | BFT | C | 1517666 |
THE DEER CREEK CORPORATION | BFN | P | 11/24/1998 | GRADE BEAM OK | GREGC | GREGC | | BFN | P | 1517677 |
THE DEER CREEK CORPORATION | BFT | P | 11/19/1998 | Need caisson logs,Eng onsite | MIKE | MIKE | | BFT | P | 1517651 |
CARLTON ELECTRIC, INC. | E= | C | 04/23/1999 | | MIKEC | MIKEC | | E= | C | 1517786 |
CARLTON ELECTRIC, INC. | E= | P | 04/22/1999 | ck wire will sealoffs. pour seal off, support conduit ceiling carl jr s. roof ok, coolers ok. | IKE | IKE | | E= | P | 1517779 |
CARLTON ELECTRIC, INC. | ER | P | 04/02/1999 | ceiling-check carl's area on final | MIKEC | MIKEC | | ER | P | 1517773 |
CARLTON ELECTRIC, INC. | ER | P | 03/26/1999 | outside soffitts | MIKEC | MIKEC | | ER | P | 1517768 |
CARLTON ELECTRIC, INC. | ES | C | 03/24/1999 | factory tech. had to replace main breaker. ok to reenergize. called into sharon 3/24/99 | MIKEC | MIKEC | | ES | C | 1517761 |
CARLTON ELECTRIC, INC. | ES | P | 03/08/1999 | 3PH 4W 1200 AMP 208/120V NEW SERVICE. C-T METERED. CARLTON ELEC | MIKEC | MIKEC | | ES | P | 1517790 |
CARLTON ELECTRIC, INC. | ES | R | 03/05/1999 | meter not set for c-t s, parallel neutrals to car wash | MIKEC | MIKEC | | ES | R | 1517754 |
CARLTON ELECTRIC, INC. | EUG | P | 03/02/1999 | tanks and islands | MIKEC | MIKEC | | EUG | P | 1517748 |
CARLTON ELECTRIC, INC. | ER | P | 02/26/1999 | soffits and bath ceiling ok support mc cable | IKE | IKE | | ER | P | 1517740 |
CARLTON ELECTRIC, INC. | ER | P | 02/18/1999 | interior walls and bath. | IKE | IKE | | ER | P | 1517734 |
CARLTON ELECTRIC, INC. | EUG | P | 02/03/1999 | sight lighting | IKE | IKE | | EUG | P | 1517728 |
CARLTON ELECTRIC, INC. | ER | P | 02/01/1999 | west and north exterior walls. partial ug trench | MIKEC | MIKEC | | ER | P | 1517722 |
CARLTON ELECTRIC, INC. | EUG | P | 01/21/1999 | conduits | MIKEC | MIKEC | | EUG | P | 1517716 |
CARLTON ELECTRIC, INC. | EUG | P | 01/11/1999 | conduits to island | MIKEC | MIKEC | | EUG | P | 1517710 |
CARLTON ELECTRIC, INC. | EUG | P | 12/14/1998 | slab gas station | MIKEC | MIKEC | | EUG | P | 1517704 |
WEST CANON HEATING & A/C | H= | C | 04/19/1999 | test & balance recieved | JIMV | JIMV | | H= | C | 1517839 |
PARKEY'S REFRIGERATION CO., INC | H= | C | 04/19/1999 | | JIMV | JIMV | | H= | C | 1517593 |
WEST CANON HEATING & A/C | HC | C | 04/09/1999 | | JOHNW | JOHNW | | HC | C | 1517812 |
WEST CANON HEATING & A/C | HI | C | 04/09/1999 | | JOHNW | JOHNW | | HI | C | 1517819 |
WEST CANON HEATING & A/C | HV | C | 04/09/1999 | | JOHNW | JOHNW | | HV | C | 1517824 |
WEST CANON HEATING & A/C | HD | C | 03/29/1999 | grease duct and wrap ok | JOHNW | JOHNW | | HD | C | 1517805 |
WEST CANON HEATING & A/C | HD | P | 03/18/1999 | WELDED GREASR DUCT OK / NEED BETTER SUPPORT ON GREASE DUCT USE ANGLE IRON OR UNISTRUT WITH ALL THREAD | JOHNW | JOHNW | | HD | P | 1517800 |
WEST CANON HEATING & A/C | HD | P | 03/04/1999 | trunks & laterals, above office & restrooms OK | JIMV | JIMV | | HD | P | 1517794 |
PARKEY'S REFRIGERATION CO., INC | HI | C | 02/25/1999 | 10# test | JOHNW | JOHNW | | HI | C | 1517587 |
PARKEY'S REFRIGERATION CO., INC | HI | T | 02/23/1999 | PAID (REC# 322921)no test | JIMV | JIMV | | HI | T | 1517580 |
PARKEY'S REFRIGERATION CO., INC | HO | C | 02/08/1999 | underground to carwash | JOHNW | JOHNW | | HO | C | 1517572 |
CUSTOM PLUMBING INC | P= | C | 04/09/1999 | ok for plbg co | MARTY | MARTY | | P= | C | 1517637 |
CUSTOM PLUMBING INC | PTO | C | 02/19/1999 | | MARTY | MARTY | | PTO | C | 1517630 |
CUSTOM PLUMBING INC | PTO | R | 02/16/1999 | back dwv test ok, get everything else ready. | MARTY | MARTY | | PTO | R | 1517623 |
CUSTOM PLUMBING INC | PTO | T | 02/12/1999 | PAID (REC# 322496)no work done, no where near ready for pto. | MARTY | MARTY | | PTO | T | 1517615 |
CUSTOM PLUMBING INC | PRD | C | 02/04/1999 | | MARTY | MARTY | | PRD | C | 1517608 |
CUSTOM PLUMBING INC | PRD | P | 02/03/1999 | use mission clamps on plastic to brass, no test west 4". | MARTY | MARTY | | PRD | P | 1517601 |
CUSTOM PLUMBING INC | PB | C | 12/17/1998 | | MARTY | MARTY | | PB | C | 1517644 |