CORONA SIERRA, INC. | B= | C | 03/16/1999 | CORRECTIONS COMPLETED; NO FIRE FINAL REQUIRED BY FIRE DEPT | DANF | DANF | | B= | C | 1551736 |
CORONA SIERRA, INC. | B= | R | 03/13/1999 | 1) DOOR TO REMAIN OPEN SIGN 2) BATHROOM SIGNAGE 3) PANIC BAR 15 LB TO UNLATCH | DANF | DANF | | B= | R | 1551728 |
CORONA SIERRA, INC. | BFR | C | 02/19/1999 | eng on file for beam sitting on masonary wall | JIMA | JIMA | | BFR | C | 1551720 |
CORONA SIERRA, INC. | BFN | C | 02/18/1999 | compaction on file ok by eng | JIMA | JIMA | | BFN | C | 1551705 |
CORONA SIERRA, INC. | BFR | P | 02/18/1999 | pending outher insp. / need stamp on eng for fram roof / vent bathrooms / walls ok // | JIMA | JIMA | | BFR | P | 1551713 |
CORONA SIERRA, INC. | BFN | P | 02/12/1999 | OK TO POUR PENDING COMPACTION LETTER; OTHER CORRECTIONS OK | DANF | DANF | | BFN | P | 1551697 |
CORONA SIERRA, INC. | BSP | R | 02/10/1999 | 1) NEED COMPACTION TESTS OF 90% PER PLANS 2) 36" DEPTH PER DETAIL 3) ISO FROM SIDEWALK; RECALL | DANF | DANF | | BSP | R | 1551689 |
CORONA SIERRA, INC. | BFT | C | 01/14/1999 | SLAB POUR UNDER COOLER OK | DANF | DANF | | BFT | C | 1551681 |
BOULTON ELECTRICAL SERVICES. | E= | C | 03/12/1999 | | MIKEC | MIKEC | | E= | C | 1551659 |
BOULTON ELECTRICAL SERVICES. | E= | R | 03/11/1999 | NOT READY | MIKEC | MIKEC | | E= | R | 1551673 |
BOULTON ELECTRICAL SERVICES. | ER | P | 02/26/1999 | DROP CEILING | GLENN | GLENN | | ER | P | 1551666 |
BOULTON ELECTRICAL SERVICES. | ER | P | 02/11/1999 | WALLS,CEILINGS, RECOMMEND REPLACING RECESSED FIXTURES. | GLENN | GLENN | | ER | P | 1551651 |
PARKEY'S REFRIGERATION CO., INC | H= | C | 03/11/1999 | | JOHNW | JOHNW | | H= | C | 1551616 |
PARKEY'S REFRIGERATION CO., INC | HD | C | 02/18/1999 | RELOCATE DUCT | JOHNW | JOHNW | | HD | C | 1551624 |
PARKEY'S REFRIGERATION CO., INC | HV | C | 02/18/1999 | | JOHNW | JOHNW | | HV | C | 1551632 |
PARKEY'S REFRIGERATION CO., INC | HI | C | 02/16/1999 | 10# test | JOHNW | JOHNW | | HI | C | 1551569 |
PARKEY'S REFRIGERATION CO., INC | HV | R | 02/16/1999 | too much bvent exposed need to move into raised portion of roof | JOHNW | JOHNW | | HV | R | 1551576 |
PARKEY'S REFRIGERATION CO., INC | HD | R | 02/16/1999 | not ready | JOHNW | JOHNW | | HD | R | 1551558 |
PARKEY'S REFRIGERATION CO., INC | P= | C | 03/09/1999 | | LEE | LEE | | P= | C | 1551609 |
PARKEY'S REFRIGERATION CO., INC | P= | P | 03/08/1999 | Need to secure the 3-comp and other sink to the wall and install expantion tank. | LEE | LEE | | P= | P | 1551601 |
PARKEY'S REFRIGERATION CO., INC | PTO | C | 02/19/1999 | | LEE | LEE | | PTO | C | 1551592 |
PARKEY'S REFRIGERATION CO., INC | PTO | P | 02/17/1999 | Need to relocate the water lines in an outside wall and install an accessable full size clean-out. | LEE | LEE | | PTO | P | 1551584 |
PARKEY'S REFRIGERATION CO., INC | PTO | R | 02/16/1999 | Canceled 9:10 | LEE | LEE | | PTO | R | 1551550 |
PARKEY'S REFRIGERATION CO., INC | PB | C | 02/09/1999 | | LEE | LEE | | PB | C | 1551644 |
PARKEY'S REFRIGERATION CO., INC | PB | P | 02/08/1999 | Need to replace quarter bends with sweeps under the slab, Need to roll all dry vents, Also the lav in the mens room is serving as a trap primer for the floor drain (dbl traped ?)Need drawings and approval for the new grease line and connected fixtures. | LEE | LEE | | PB | P | 1551543 |
PARKEY'S REFRIGERATION CO., INC | PB | R | 02/05/1999 | Not ready | LEE | LEE | | PB | R | 1551534 |