GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | C | 03/29/2000 | | TERRYB | TERRYB | | B= | C | 1720035 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | C | 03/29/2000 | | TERRYB | TERRYB | | BFR | C | 1720043 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 02/15/2000 | need to check fire taping before droping tile | TERRYB | TERRYB | | BFR | P | 1720028 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 01/24/2000 | framing of shaft and firedampers ok | TERRYB | TERRYB | | BSP | P | 1720021 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | P | 01/19/2000 | WENT OVER FRAMING QUESTIONS WITH SUPER | TERRYB | TERRYB | | BFR | P | 1720050 |
GREEN ELECTRIC INC | E= | C | 03/24/2000 | | MIKEC | MIKEC | | E= | C | 1720191 |
GREEN ELECTRIC INC | ER | C | 03/09/2000 | ceiling. | RON | RON | | ER | C | 1720180 |
GREEN ELECTRIC INC | ER | P | 03/06/2000 | perimiter rooms, new hallway ceilings. bring old corridor ceiling up to 1999 nec. | RON | RON | | ER | P | 1720174 |
GREEN ELECTRIC INC | ER | P | 02/29/2000 | CHECKED GROUNDS IN PATENT CARE AREAS | MIKEC | MIKEC | | ER | P | 1720199 |
GREEN ELECTRIC INC | ER | P | 01/20/2000 | walls-----when wire is pulled check for ground wires in patient care areas | JERRY | JERRY | | ER | P | 1720166 |
COLORADO SHEET METAL CO., INC. | HD | C | 03/28/2000 | | JOHNW | JOHNW | | HD | C | 1720160 |
COLORADO SHEET METAL CO., INC. | H= | C | 03/28/2000 | | JOHNW | JOHNW | | H= | C | 1720152 |
COLORADO SHEET METAL CO., INC. | H= | P | 03/27/2000 | radiatioin dampers ok / need to go over job with contractor Gary call me at the office 327-2944 | JOHNW | JOHNW | | H= | P | 1720144 |
COLORADO SHEET METAL CO., INC. | H= | P | 03/24/2000 | need to support all 4 cornners of radiation dampers / all supply , return and exhaust must have radiation dampers in them , complete duct work on roof . | JOHNW | JOHNW | | H= | P | 1720135 |
COLORADO SHEET METAL CO., INC. | H= | P | 03/20/2000 | Radiant dampers and diffusers at Nurse's station, all supply and exhaust grilles except for duct and grilles on EF-2, complete. | LYNNS | LYNNS | | H= | P | 1720127 |
COLORADO SHEET METAL CO., INC. | HD | P | 02/15/2000 | | JOHNW | JOHNW | | HD | P | 1720119 |
COLORADO SHEET METAL CO., INC. | HD | P | 01/25/2000 | fire damper framing ok /' additional dampers to come | JOHNW | JOHNW | | HD | P | 1720111 |
COLORADO SHEET METAL CO., INC. | HD | P | 01/14/2000 | 3rd floor above ceiling rough and risers up to ceiling / still need fire/smoke dampers frame | JOHNW | JOHNW | | HD | P | 1720103 |
OLSON PLUMBING & HEATING COMPANY | P= | C | 04/04/2000 | | JIMV | JIMV | | P= | C | 1720094 |
OLSON PLUMBING & HEATING COMPANY | P= | P | 03/20/2000 | all ok except scope cleaning room not complete | DOUGR | DOUGR | | P= | P | 1720086 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 02/11/2000 | everything done except above floor on 4th floor, also, post change of layout on 4th floor | DOUGR | DOUGR | | PTO | P | 1720079 |
OLSON PLUMBING & HEATING COMPANY | P16 | C | 01/20/2000 | process htg piping | JIMV | JIMV | | P16 | C | 1720065 |
OLSON PLUMBING & HEATING COMPANY | PTO | P | 01/20/2000 | need 4th floor sink & nurse station sink, all else complete | JIMV | JIMV | | PTO | P | 1720072 |
OLSON PLUMBING & HEATING COMPANY | P16 | P | 12/10/1999 | discuss relocation of piping over ICU | JIMV | JIMV | | P16 | P | 1720057 |