RIVERWOOD HOMES OF COLORADO, INC. | B= | C | 06/14/2001 | | STEVEJ | STEVEJ | | B= | C | 1817389 |
RIVERWOOD HOMES OF COLORADO, INC. | B= | P | 12/04/2000 | HAVE INSULATION CERTIFICATE | GREGC | GREGC | | B= | P | 1817383 |
RIVERWOOD HOMES OF COLORADO, INC. | B= | P | 12/01/2000 | Temp CO: TCO | ROLF | ROLF | | B= | P | 1817325 |
RIVERWOOD HOMES OF COLORADO, INC. | B= | P | 12/01/2000 | PERMANENT NUMBERS AT STREET-DECK NOT FINISHED-INSULATION CERTIFICATE-FINAL GRADE | GREGC | GREGC | | B= | P | 1817375 |
RIVERWOOD HOMES OF COLORADO, INC. | BLA | C | 10/23/2000 | | PHIL | PHIL | | BLA | C | 1817318 |
RIVERWOOD HOMES OF COLORADO, INC. | BFR | C | 09/29/2000 | | PHIL | PHIL | | BFR | C | 1817310 |
RIVERWOOD HOMES OF COLORADO, INC. | BFR | R | 09/28/2000 | LOAD AT ZZB TRUSS STILL HAS NOT BEEN ADDRESS AS DISCUSSED WITH CONTRACTOR AT OFFICE YESTERDAY THE9/27-STILL DONT HAVE ENHANCERS ON THE ZZA AND ZZB TRUSSES AS DISCUSSED WITH CONJTRACTOR ON THE SAME-TRUSSES AT PORCH HAVE NOT BEEN CLIPPED-FIREPLACE NEEDS TO HAVE 3/4 FIRESTOP AT 10'-INSULATORS ARE INSULATING,WHO GAVE THE OK I DIDN'T!!!! | GREGC | GREGC | | BFR | R | 1817362 |
RIVERWOOD HOMES OF COLORADO, INC. | BSP | P | 09/28/2000 | 2 HOLES IN ADDITION TO THE 8 THAT WERE DONE ON 9/27 ARE OK | GREGC | GREGC | | BSP | P | 1817369 |
RIVERWOOD HOMES OF COLORADO, INC. | BFR | R | 09/27/2000 | CANCEL PER CONTRACTOR | PHIL | PHIL | | BFR | R | 1817303 |
RIVERWOOD HOMES OF COLORADO, INC. | BSP | P | 09/26/2000 | 3 HOLES REAR OK | GREGC | GREGC | | BSP | P | 1817356 |
RIVERWOOD HOMES OF COLORADO, INC. | BFR | T | 09/26/2000 | PAID (REC#382756)ADD 2X6 UNDER EACH SQUASH BLOCK FOR DIRECT BEARING-FIRESTOP FIREPLACE-ENG HAS NOT BEEN DONE TO THE ENG LETTER,STILL MISSING ENHANCERS AT THE ZZA AND ZZB-PORCH FRAME STILL COVERED-ZZB TRUSS DETAIL SHOWING 2 INT BEARINGS AND CONFIGURATION NOT MATCHING AT ONE END-A-2 TRUSSES STILL NOT LATERAL BRACED | GREGC | GREGC | | BFR | T | 1817349 |
RIVERWOOD HOMES OF COLORADO, INC. | BFR | R | 09/22/2000 | FIELD CANCELLED BY RBD | BLAINE | BLAINE | | BFR | R | 1817296 |
RIVERWOOD HOMES OF COLORADO, INC. | BFR | T | 09/20/2000 | PAID (REC#382044)1. 2- LS90 AT GARAGE MICRO PER PLAN 2. BRACE A2, AND ADD H2.5 3. FILL HANGER AT GX 4. TRUSS ENGINEERING ZZA,ZZB 5. STEEL COLUMNS MISSING ZZA,ZZB, AND BEARING ENHANCEMENT 6. PORCH FRAME COVERED 7. ROLL BLOCKS 8. FIRESTOP 9. DECK NOT FRAMED 10. 2X6 COLUMNS UNDER STEEL BEAMS NOT TO PLAN 11. WEB STIFFNERS 12.POINT LOADS | PHIL | PHIL | | BFR | T | 1817289 |
RIVERWOOD HOMES OF COLORADO, INC. | BFR | T | 09/18/2000 | PAID (REC#381854)HOUSE NOT READY FOR FRAME INSPECTION --- TOO MANY ITEMS TO LIST HERE --- RECALL | BLAINE | BLAINE | | BFR | T | 1817284 |
RIVERWOOD HOMES OF COLORADO, INC. | BFD | C | 06/30/2000 | | PHIL | PHIL | | BFD | C | 1817276 |
RIVERWOOD HOMES OF COLORADO, INC. | BFD | P | 06/23/2000 | STILL NEED UNDER SLAB DRAIN | PHIL | PHIL | | BFD | P | 1817270 |
RIVERWOOD HOMES OF COLORADO, INC. | BFN | C | 06/12/2000 | INCLUDES INT PADSAND 1 EXT FRONT PIER-HAVE COMPATION-LWI-FLOAT-PERIMETER AND UNDERSLAB- | GREGC | GREGC | | BFN | C | 1817342 |
RIVERWOOD HOMES OF COLORADO, INC. | BFT | C | 06/06/2000 | NO INT PADS | GREGC | GREGC | | BFT | C | 1817333 |
FORD ELECTRIC INC | E= | C | 11/28/2000 | ford to id boxs in bsmt for future | ARNOLD | ARNOLD | | E= | C | 1817242 |
FORD ELECTRIC INC | ER | C | 09/12/2000 | | ARNOLD | ARNOLD | | ER | C | 1817235 |
FORD ELECTRIC INC | ES | C | 09/08/2000 | ok to reseal for new 3wire undgrn by ford elec. | ARNOLD | ARNOLD | | ES | C | 1817221 |
FORD ELECTRIC INC | EUG | C | 09/08/2000 | tape in | ARNOLD | ARNOLD | | EUG | C | 1817227 |
FORD ELECTRIC INC | ER | R | 09/08/2000 | wiring in return air in a couple of places-block off so soffits arent involved-please add outlet on 2' wall bedroom on bent wall by bath ? do you have adequate circuits for the unfin bsmt ? | ARNOLD | ARNOLD | | ER | R | 1817214 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 11/30/2000 | 6-supplies in unfinished basement | TIM | TIM | | H= | C | 1817263 |
J & J MECHANICAL, INC | HC | C | 10/23/2000 | OK FOR METER | KYE | KYE | | HC | C | 1817200 |
J & J MECHANICAL, INC | HC | C | 10/11/2000 | B4 FINAL NEED GAS RISERS TAGGED 2LB SYSTEM ON BOTH RISERS, REPLACE VENT CONNECTOR HAS A HOLE IN OUTER LINING | TIM | TIM | | HC | C | 1817192 |
J & J MECHANICAL, INC | HC | R | 10/09/2000 | need tie in at house, replace connector on furnace (has a hole in it) | TIM | TIM | | HC | R | 1817158 |
J & J MECHANICAL, INC | HO | C | 10/09/2000 | 60lb test | TIM | TIM | | HO | C | 1817165 |
J & J MECHANICAL, INC | H16 | C | 09/14/2000 | Per conversation with Charlie Jones he is going to have peoples increase to 2lb system. need approval and 60lb test on outside, if not inside gas sizing to small | TIM | TIM | | H16 | C | 1817131 |
J & J MECHANICAL, INC | HC | R | 09/14/2000 | need to move outside gas from window if regulator is at house, see notes H16 | TIM | TIM | | HC | R | 1817140 |
J & J MECHANICAL, INC | HI | C | 09/14/2000 | inside ok will need 2lb system 11/2 2-furnaces waterheater 2-fireplaces bar-b-q stub into garage | TIM | TIM | | HI | C | 1817146 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 09/13/2000 | | PAT | PAT | | HRR | C | 1817255 |
J & J MECHANICAL, INC | HI | R | 09/12/2000 | all house piping to small 330,000BTU without garage heater(still don't know load) 600ft column | TIM | TIM | | HI | R | 1817124 |
J & J MECHANICAL, INC | HO | P | 09/12/2000 | 2" NEED 2LB SYSTEM | TIM | TIM | | HO | P | 1817184 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | R | 09/11/2000 | canceled per Nellie 11:20 | TIM | TIM | | HRR | R | 1817248 |
J & J MECHANICAL, INC | HI | R | 09/08/2000 | need BTU load on waterheater and stub to garage (appeares 11/4 will be to small) | TIM | TIM | | HI | R | 1817108 |
J & J MECHANICAL, INC | P= | C | 11/30/2000 | | TIM | TIM | | P= | C | 1817179 |
J & J MECHANICAL, INC | P= | P | 11/27/2000 | sleeve water line thru foundation | TIM | TIM | | P= | P | 1817173 |
J & J MECHANICAL, INC | PTO | C | 09/14/2000 | | TIM | TIM | | PTO | C | 1817152 |
J & J MECHANICAL, INC | PTO | R | 09/12/2000 | VENT STILL TIES TOGETHER BELOW FLOOD LEVEL RIM ON KITCHEN SINK | TIM | TIM | | PTO | R | 1817207 |
J & J MECHANICAL, INC | PTO | R | 09/08/2000 | barrel of san tee must be 2 sizes larger than largest inlet (washer and laundry tub) tie vents together 6" above flood level, leak on H20 by foundation | TIM | TIM | | PTO | R | 1817117 |
J & J MECHANICAL, INC | PB | C | 06/19/2000 | 4" to 4th wye. | DARYL | DARYL | | PB | C | 1817101 |