DALE CLARK CONSTRUCTION | BLA | C | 08/24/2001 | | BLAINE | BLAINE | | BLA | C | 1955768 |
DALE CLARK CONSTRUCTION | BSP | P | 08/24/2001 | REAR DECK PIER OK | BLAINE | BLAINE | | BSP | P | 1955772 |
DALE CLARK CONSTRUCTION | BSP | T | 08/20/2001 | PAID (REC#424523)ADDITIONAL PLAN REVIEW TIME: $30.000 From: STEPHEN | STEPHEN | STEPHEN | | BSP | T | 1956016 |
DALE CLARK CONSTRUCTION | BSP | R | 08/20/2001 | NOT READY--NOT 30'' DEEP / NO ENGINEERING ON SITE | BLAINE | BLAINE | | BSP | R | 1955760 |
DALE CLARK CONSTRUCTION | BFR | C | 08/07/2001 | CHECK CUT TJI AND T-POSTS AT FINAL | BLAINE | BLAINE | | BFR | C | 1956008 |
DALE CLARK CONSTRUCTION | BFD | C | 08/01/2001 | HAVE SOILS LETTER AND COMPACTION, ENTIRE STRUCTURE IS DRAINED | BLAINE | BLAINE | | BFD | C | 1955786 |
DALE CLARK CONSTRUCTION | BFR | R | 08/01/2001 | ANCHOR T POST,S/NAIL STAIR STRAPS/3 POINT BEARING TRUSS HAVE NO SUPPORT OR UPLIFT ATTACHMENTS/BLOCK AND SHEAR TRUSS,S OVER 8"/GARAGE TRIMMER SUPPORTS/TRUSS CLIPS MISSING AND NEED NAILED OFF/FIRESTOPS/KING STUD AT PORCH BEAMS/CUT JOIST,S/TEMPERED GLASS NEXT TO DOOR,S | FRANK | FRANK | | BFR | R | 1955686 |
DALE CLARK CONSTRUCTION | BSP | P | 07/10/2001 | FRONT PORCH PIERS ONLY - OK PER/ ENGINEERS LETTER - LETTER W/ INSPECTOR | STEVEJ | STEVEJ | | BSP | P | 1955677 |
DALE CLARK CONSTRUCTION | BSP | T | 07/09/2001 | PAID (REC#418441)ADDITIONAL PLAN REVIEW TIME: $30.000 From: TIMC | TIMC | TIMC | | BSP | T | 1955781 |
DALE CLARK CONSTRUCTION | BSP | P | 07/06/2001 | DECK PIERS OK | BLAINE | BLAINE | | BSP | P | 1955672 |
DALE CLARK CONSTRUCTION | BSP | T | 06/21/2001 | PAID (REC#417932)ADDITIONAL PLAN REVIEW TIME: $30.000 From: TIMC | TIMC | TIMC | | BSP | T | 1955776 |
DALE CLARK CONSTRUCTION | BFD | P | 05/14/2001 | NEED FULL,STAMPED SOILS LETTER---OK TO BACKFILL | BLAINE | BLAINE | | BFD | P | 1955665 |
DALE CLARK CONSTRUCTION | BFN | P | 04/27/2001 | NEED REVISED FOUNDATION DESIGN TO SHOW FROST WALL INSTEAD OF BASEMENT WALLS/NEED FULL SOILS LETTER | FRANK | FRANK | | BFN | P | 1955659 |
DALE CLARK CONSTRUCTION | BFT | C | 04/25/2001 | COMPACTION LETTER ON SITE/INCLUDES PADS | FRANK | FRANK | | BFT | C | 1955652 |
SERVICE ELECTRIC COMPANY | ES | C | 08/10/2001 | TEMP TO PERMANENT | RED | RED | | ES | C | 1956126 |
SERVICE ELECTRIC COMPANY | ER | C | 07/31/2001 | | ARNOLD | ARNOLD | | ER | C | 1956111 |
SERVICE ELECTRIC COMPANY | ER | T | 07/30/2001 | PAID (REC#421707)NOT READY: TRIP-FEE PER ARNOLD @ 30-JUL-2001 12:09:34 | ARNOLD | ARNOLD | | ER | T | 1956119 |
SERVICE ELECTRIC COMPANY | ER | R | 07/30/2001 | not ready-trip fee | ARNOLD | ARNOLD | | ER | R | 1956105 |
SERVICE ELECTRIC COMPANY | ER | R | 07/27/2001 | complete reinsp-strip rmx,make up grns outside boxs-tie grns together all bxs-re-id whites not used as neutrals-outlet over 6' from center of slider-need lots of nail plates-hood not on app circuit-replace broken 2gang in gar.replace damaged romex kit cir by stairs-dont use j straps for securing cable-protect rmx 6' of attic access see service | ARNOLD | ARNOLD | | ER | R | 1956175 |
SERVICE ELECTRIC COMPANY | ES | R | 07/27/2001 | need load calc-sub panel not bonded correctly-sub panel in fire wall-bending radius of ser cable-need to reinsp when service is called in no undgrn insp-dont use j straps on ser cable | ARNOLD | ARNOLD | | ES | R | 1956098 |
GLASER GAS, INC | HO | C | 08/23/2001 | 60# TEST. | DARYL | DARYL | | HO | C | 1956024 |
JOHNSON PLUMBING COMPANY, INC. | HI | C | 07/27/2001 | 1" furnace waterheater | TIM | TIM | | HI | C | 1956084 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 07/23/2001 | B4 final seal return header in mech room | TIM | TIM | | HRR | C | 1956090 |
JOHNSON PLUMBING COMPANY, INC. | HLP | C | 05/29/2001 | 4" complete to south side foundation | TIM | TIM | | HLP | C | 1956047 |
HOMEOWNER | PWO | C | 07/26/2001 | | TIM | TIM | | PWO | C | 1955648 |
JOHNSON PLUMBING COMPANY, INC. | PTO | C | 07/26/2001 | | TIM | TIM | | PTO | C | 1956077 |
JOHNSON PLUMBING COMPANY, INC. | PTO | R | 07/24/2001 | only 1 fixture unit allowed on 11/2 horizontial | TIM | TIM | | PTO | R | 1956070 |
JOHNSON PLUMBING COMPANY, INC. | PTO | R | 07/23/2001 | canceled per Nellie | TIM | TIM | | PTO | R | 1956061 |
JOHNSON PLUMBING COMPANY, INC. | PB | C | 05/29/2001 | 4" | TIM | TIM | | PB | C | 1956054 |
JOHNSON PLUMBING COMPANY, INC. | PB | R | 05/25/2001 | need to remove or cover no trespass signs | TIM | TIM | | PB | R | 1956039 |