MICHAEL C. BRADLEY | B= | C | 03/12/2002 | | GREGC | GREGC | | B= | C | 1956513 |
MICHAEL C. BRADLEY | B= | R | 03/11/2002 | CANCEL | PHIL | PHIL | | B= | R | 1956427 |
MICHAEL C. BRADLEY | BSP | T | 02/19/2002 | PAID (REC#447787)ADDITIONAL PLAN REVIEW TIME: $40.000 From: RONW | RONW | RONW | | BSP | T | 1956507 |
MICHAEL C. BRADLEY | B= | R | 02/08/2002 | PERMANENT NUMBERS ROAD-HORIZINTALS AT DECK OVER 4" SPACE-TRIANGLE SHAPED HOLE DECK NEEDS FILLED-SEAL GAS LINE AT GARAGE LID AND WIRES AND FIREWALL AND LID-LID FOR ACCESS NEEDS CASING-SEAL GARAGE OHD BRACKETS-FIRESTOP TUB-DECK PLANS | GREGC | GREGC | | B= | R | 1956501 |
MICHAEL C. BRADLEY | BFR | C | 05/16/2001 | | GREGC | GREGC | | BFR | C | 1956494 |
MICHAEL C. BRADLEY | BLA | C | 05/11/2001 | | GREGC | GREGC | | BLA | C | 1956486 |
MICHAEL C. BRADLEY | BFR | P | 05/10/2001 | OK TO ROCK WALLS BUT NOT ANY LIDS THAT WIL PREVENT THE OVERFRAME FROM BEING SEEN-LEGS DOWN AT 3 OVERFRAMES | GREGC | GREGC | | BFR | P | 1956480 |
MICHAEL C. BRADLEY | BFR | T | 04/30/2001 | PAID (REC#410149)HTT22 ANCHORS NOT INSTALLED CORRECTLY-LEGS DOWN AT OVERFRAME-H-7 STRAP AT GO1-DIRECT BEARING ALL POINT LOADS TO WALL | GREGC | GREGC | | BFR | T | 1956472 |
MICHAEL C. BRADLEY | BFR | P | 04/25/2001 | BLOCK TRUSSES OVER 8"-LEGS DOWN AT OVERFRAME-GO1 NEEDS BEARING BLOCKS AND H-7 STAPS-GO6 HTT22 ANCHORS-GO8 BEARING BLOCKS EA END-CARRY ALL LOADS DIRECT BEARING TO THE WALL | GREGC | GREGC | | BFR | P | 1956466 |
MICHAEL C. BRADLEY | BSP | R | 04/20/2001 | 1)BLOCK ALL TRUSS HEELS >8'' 2)SHIM BEARING UNDER G04 GIRDER 3)DIAGONALS ONM LATERAL BRACES 4)NEED T09 TRUSS DETAILS 5)T BRACE T11 TRUSS 6)NEED DETAILS FOR T13,T14,T15 TRUSSES 7)NAIL PATTERN,5 STUD BEARING,AND BEARING BLOCKS EACH END G06 GIRDER 8)ADD KING STUD EACH SIDE MASTER BAY WINDOW 9)BLOCK ENDS OF GARAGE DOOR BRACKETS 10)T BRACE T01 TRUSS IN GARAGE 11)STRAP PLATE BREAKS <48'' 12)CARRY POINT LOADS TO FOUNDATION | BLAINE | BLAINE | | BSP | R | 1956459 |
MICHAEL C. BRADLEY | BSP | T | 04/19/2001 | PAID (REC#407381)ADDITIONAL PLAN REVIEW TIME: $30.000 From: STEPHEN | STEPHEN | STEPHEN | | BSP | T | 1956452 |
MICHAEL C. BRADLEY | BSP | P | 04/03/2001 | NOTE: THE DRAIN HAS NEVER BEEN COMPLETED,NEEDS TO BE CLEARED UP AND SIGNED OFF -REAR PIERS OK-FROVIDE ENG FOR THE PIERS AT FRONT PORCH | GREGC | GREGC | | BSP | P | 1956447 |
MICHAEL C. BRADLEY | BFD | R | 01/19/2001 | DRAIN CALLS FOR ENTIRE | GREGC | GREGC | | BFD | R | 1956440 |
MICHAEL C. BRADLEY | BFN | C | 01/08/2001 | LWI-ENTIRE-LOAT-HAVE LETTER FOR THE ADDED COUNTERFORT AT THE SOUTH WALL | GREGC | GREGC | | BFN | C | 1956434 |
MICHAEL C. BRADLEY | BFT | C | 01/05/2001 | INCLUDES PADS | BLAINE | BLAINE | | BFT | C | 1956421 |
UNITED ELECTRIC OF COLORADO | E= | C | 01/29/2002 | | JERRY | JERRY | | E= | C | 1956381 |
UNITED ELECTRIC OF COLORADO | E= | T | 12/17/2001 | PAID (REC#445135)list not complete from last inspection | JERRY | JERRY | | E= | T | 1956374 |
UNITED ELECTRIC OF COLORADO | E= | R | 12/13/2001 | protect romex to under cabinet lights,grounding electrode is connected to gas pipe,water and gas pipe bond | JERRY | JERRY | | E= | R | 1956367 |
UNITED ELECTRIC OF COLORADO | E= | R | 12/11/2001 | locked 4:54 | JERRY | JERRY | | E= | R | 1956362 |
UNITED ELECTRIC OF COLORADO | E= | T | 12/10/2001 | PAID (REC#439850)locked 2:46 | JERRY | JERRY | | E= | T | 1956355 |
UNITED ELECTRIC OF COLORADO | ER | C | 04/03/2001 | | JERRY | JERRY | | ER | C | 1956340 |
UNITED ELECTRIC OF COLORADO | ES | C | 04/03/2001 | 3-wire underground,united electric,new home | JERRY | JERRY | | ES | C | 1956347 |
UNITED ELECTRIC OF COLORADO | EUG | C | 01/26/2001 | | JERRY | JERRY | | EUG | C | 1956333 |
UNITED ELECTRIC OF COLORADO | EUG | R | 01/24/2001 | tape in bottom of ditch | JERRY | JERRY | | EUG | R | 1956326 |
BLACK FOREST HEATING | H= | C | 02/05/2002 | unfinished basement, 4 heat runs 0 return, no ac | JEFF | JEFF | | H= | C | 1956414 |
BLACK FOREST HEATING | HC | C | 04/18/2001 | | TIM | TIM | | HC | C | 1956400 |
BLACK FOREST HEATING | HRR | C | 04/18/2001 | | TIM | TIM | | HRR | C | 1956407 |
D J HANNON PLBG. & HTG., INC. | HI | C | 04/17/2001 | 11/4 FURNACE WATERHEATER FIREPLACE BAR-B-Q GAS TO GARAGE FUTURE HEATER | TIM | TIM | | HI | C | 1956319 |
BLACK FOREST HEATING | HRR | P | 04/16/2001 | complete bath fans, header return above furnace, seal holes in TJIs at returns | DOUGR | DOUGR | | HRR | P | 1956395 |
PLUMB RIGHT PLUMBING, LLC. | P= | C | 02/05/2002 | unfinished basement | JEFF | JEFF | | P= | C | 1956529 |
HOMEOWNER | PWO | C | 07/03/2001 | | JEFF | JEFF | | PWO | C | 1956312 |
PLUMB RIGHT PLUMBING, LLC. | PTO | C | 04/18/2001 | | TIM | TIM | | PTO | C | 1956524 |
PLUMB RIGHT PLUMBING, LLC. | PTO | P | 04/16/2001 | complete water piping to water heaters & well tank area, toilet less than 15'' from tub in hall bath, need 1 more 1 1\2'' vent thru roof, hose bib in garage needs to be freeze proof | DOUGR | DOUGR | | PTO | P | 1956519 |
MARATHON PLUMBING & HEATING INC. | PB | C | 01/12/2001 | left word if this is propane gas need to install drain and have it inspected | TIM | TIM | | PB | C | 1956388 |