HUGHES-SMITH, INC | B= | C | 10/09/2001 | Received letter from William Hoffmann(19181) indicating that the rock retaining walls are OK as constructed | MIKE | MIKE | | B= | C | 2076991 | HUGHES-SMITH, INC | B= | P | 10/04/2001 | Need engineer letter for rock retaining walls over 4' height | MIKE | MIKE | | B= | P | 2076985 | HUGHES-SMITH, INC | B= | R | 09/10/2001 | Problems not corrected | MIKE | MIKE | | B= | R | 2076981 | HUGHES-SMITH, INC | B= | P | 08/29/2001 | Heat inspection,Need all guardrails,Need engineer inspection report for rock retaining walls over 4' height | MIKE | MIKE | | B= | P | 2076976 | HUGHES-SMITH, INC | BFR | C | 08/21/2001 | | MIKE | MIKE | | BFR | C | 2076970 | HUGHES-SMITH, INC | BFR | R | 08/17/2001 | Deck framing not complete | MIKE | MIKE | | BFR | R | 2076965 | HUGHES-SMITH, INC | BFR | P | 08/10/2001 | Need to inspect deck attached to treehouse | MIKE | MIKE | | BFR | P | 2076952 | HUGHES-SMITH, INC | BFT | C | 08/10/2001 | Received letter from CTL Thompson(33394) indicating pad footing on excavation cut OK as corrected | MIKE | MIKE | | BFT | C | 2076959 | HUGHES-SMITH, INC | BFT | P | 08/09/2001 | (2) 16" diameter deck piers @ creek OK | MIKE | MIKE | | BFT | P | 2076946 | HUGHES-SMITH, INC | BFR | R | 08/09/2001 | Need completed footing inspection,Heat inspection,Rafter hanger nails,Floor beam hanger nails,Complete post base bolts | MIKE | MIKE | | BFR | R | 2076940 | HUGHES-SMITH, INC | BFT | R | 08/08/2001 | Problem not corrected | MIKE | MIKE | | BFT | R | 2076935 | HUGHES-SMITH, INC | BFR | R | 08/06/2001 | Need complete footing inspection | MIKE | MIKE | | BFR | R | 2076928 | HUGHES-SMITH, INC | BFT | R | 07/03/2001 | Upper pad footing is too close to excavation cut,(1) 5' sq pad OK | MIKE | MIKE | | BFT | R | 2076922 | HUGHES-SMITH, INC | BFT | P | 06/27/2001 | (4) 16" dia piers on pads OK | MIKE | MIKE | | BFT | P | 2076917 | HUGHES-SMITH, INC | BFT | P | 06/26/2001 | (4) 5'x 5' x16" pad footings OK | MIKE | MIKE | | BFT | P | 2076911 | WISE ELECTRIC, INC. | E= | C | 08/27/2001 | | MIKEC | MIKEC | | E= | C | 2077045 | WISE ELECTRIC, INC. | E= | P | 08/22/2001 | need information on pump cable (STOW type insulation), lights to be installed, arc shields on receptacles, relabeling of panel in barn, check outside GFI along light poles, pump control and disconnect wiring | TERRY | TERRY | | E= | P | 2077040 | WISE ELECTRIC, INC. | ER | C | 08/06/2001 | | MIKEC | MIKEC | | ER | C | 2077034 | HEATING & PLUMBING ENGINEERS, INC | H= | C | 08/29/2001 | Final complete. | LYNNS | LYNNS | | H= | C | 2077024 | HEATING & PLUMBING ENGINEERS, INC | HV | C | 08/10/2001 | Vent off unit heater OK. Before final brace unit to wall. | LYNNS | LYNNS | | HV | C | 2077014 | HEATING & PLUMBING ENGINEERS, INC | HI | C | 08/09/2001 | | JIMV | JIMV | | HI | C | 2077009 | HEATING & PLUMBING ENGINEERS, INC | P= | C | 08/23/2001 | summer use facility, no freeze protection | JIMV | JIMV | | P= | C | 2077019 | HEATING & PLUMBING ENGINEERS, INC | PTO | C | 08/07/2001 | summer use utilities, underground shut-off / drain for water service | JIMV | JIMV | | PTO | C | 2077005 | HEATING & PLUMBING ENGINEERS, INC | PTO | T | 08/06/2001 | PAID (REC#422689)NO TEST: TRIP-FEE PER LEE @ 06-AUG-2001 15:25:55 | LEE | LEE | | PTO | T | 2077030 | HEATING & PLUMBING ENGINEERS, INC | PTO | R | 08/06/2001 | Still no test on the DWV and will need letter from engineer for underground H20 stating heat tape would be acceptable or resubmit plans for approval, phoned in trip-fee | LEE | LEE | | PTO | R | 2077001 | HEATING & PLUMBING ENGINEERS, INC | PTO | P | 08/03/2001 | No test on DWV, concerns about freeze protection on H20, plans show self draining yard hydrant, plumber wants to use heat tape, also note water not run to sink at this time | LEE | LEE | | PTO | P | 2076997 |
|
|