STIMACK CONSTRUCTION CO., INC | B= | C | 01/07/2002 | NO CARD ON SITE | GREGC | GREGC | | B= | C | 2122914 |
STIMACK CONSTRUCTION CO., INC | B= | P | 12/28/2001 | TEMPERED GLASS ENTRY DOOR, (NO MARK) | PHIL | PHIL | | B= | P | 2122813 |
STIMACK CONSTRUCTION CO., INC | B= | R | 12/25/2001 | NUMBERS ON THE HOUSE-TEMPERED GLAS FRONT DOOR-SEAL FIREWALL-HANDRAIL TO HIGH AND NOT LONG ENOUGH AT GARAGE-VAPOR BARIER IN CRAWL AND VENTS | GREGC | GREGC | | B= | R | 2122907 |
STIMACK CONSTRUCTION CO., INC | BFR | C | 10/24/2001 | | PHIL | PHIL | | BFR | C | 2122806 |
STIMACK CONSTRUCTION CO., INC | BFR | P | 10/23/2001 | VERSA LAM HEADERS PER PLANS 72" OR GREATER-ANCHOR T/POST BASES-OK TO INSULATE | GREGC | GREGC | | BFR | P | 2122900 |
STIMACK CONSTRUCTION CO., INC | BSP | P | 10/09/2001 | PIERS AT FRONT AND REAR OK | GREGC | GREGC | | BSP | P | 2122892 |
STIMACK CONSTRUCTION CO., INC | BSP | P | 08/21/2001 | ANCHOR BOLTS AT SILL AND SAW CUTS AT POSTS OK | GREGC | GREGC | | BSP | P | 2122886 |
STIMACK CONSTRUCTION CO., INC | BSP | P | 08/20/2001 | BOTTOM PLATE AT FOUNDATION WALL NEEDS ANCHOR BOLT 12" FROM PLATE BREAKS | GREGC | GREGC | | BSP | P | 2122820 |
STIMACK CONSTRUCTION CO., INC | BSP | P | 08/20/2001 | SAW CUTS AT T/POSTS ARE NOT COMPLETE CHECK AT FINAL | GREGC | GREGC | | BSP | P | 2122879 |
A ALL ELECTRIC CONTRACTORS, IN | E= | C | 12/18/2001 | | JERRY | JERRY | | E= | C | 2122798 |
A ALL ELECTRIC CONTRACTORS, IN | E= | T | 12/12/2001 | PAID (REC#440153)TRIP-FEE PER JERRY @ 12-dec-2001 14:54:52 (NOT READY): not ready,too much to list,complete reinspection | JERRY | JERRY | | E= | T | 2122646 |
A ALL ELECTRIC CONTRACTORS, IN | ES | C | 10/26/2001 | 3-wire overhead to underground,a all electric,new service to home after fire | JERRY | JERRY | | ES | C | 2122632 |
A ALL ELECTRIC CONTRACTORS, IN | EUG | C | 10/26/2001 | | JERRY | JERRY | | EUG | C | 2122639 |
A ALL ELECTRIC CONTRACTORS, IN | ER | C | 10/10/2001 | | JERRY | JERRY | | ER | C | 2122625 |
A ALL ELECTRIC CONTRACTORS, IN | ER | T | 10/01/2001 | PAID (REC#431352)trip fee-2nd trip-while checking for crimp installation i found not all of the crimps were installed properly and found a switch with not grn tail-recheck entire house | ARNOLD | ARNOLD | | ER | T | 2122618 |
A ALL ELECTRIC CONTRACTORS, IN | ER | R | 09/26/2001 | back to back boxes in garage fire wall,use correct crimp tool,install stairs | JERRY | JERRY | | ER | R | 2122611 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | C | 12/21/2001 | | DARYL | DARYL | | H= | C | 2122604 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | P | 12/19/2001 | Need comb air termination. | DARYL | DARYL | | H= | P | 2122597 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | R | 12/13/2001 | lower rain collar, gas bond, proper sized filter, osa covered, seal between plenums as noted before, rest ok, unfinished basement, 5 heat runs 0 return, no ac | JEFF | JEFF | | H= | R | 2122590 |
GUILLORY PLUMBING & HEATING | HC | C | 11/28/2001 | | DALE | DALE | | HC | C | 2122523 |
GUILLORY PLUMBING & HEATING | HI | C | 11/28/2001 | | DALE | DALE | | HI | C | 2122532 |
GUILLORY PLUMBING & HEATING | HI | R | 10/31/2001 | see HI notes 10/11, changed to reject, no access inside to verify if system will work with added length!!!!!!!!!!!!!!! | JEFF | JEFF | | HI | R | 2122516 |
CHIEF HEATING AND GAS CORP. | HC | R | 10/31/2001 | see HI notes 10/31 | JEFF | JEFF | | HC | R | 2122921 |
CHIEF HEATING AND GAS CORP. | HO | C | 10/31/2001 | 290' of 2" yard line, 10 lb. test | JEFF | JEFF | | HO | C | 2122929 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HRR | C | 10/22/2001 | by final seal return air at basement between trunk lines and seal duct at south end | DALE | DALE | | HRR | C | 2122582 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HRR | R | 10/18/2001 | no one on site, what are the correction items? | DALE | DALE | | HRR | R | 2122575 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HRR | P | 10/17/2001 | Contractor to finish all items. | DARYL | DARYL | | HRR | P | 2122568 |
GUILLORY PLUMBING & HEATING | HI | R | 10/11/2001 | CHANGED TO REJECT, SEE HI/HO NOTES 10/31, 125K FURNACE; 40K? WATER HEATER; 10# TEST. ASSUMES METER BY HOUSE. | DARYL | DARYL | | HI | R | 2122562 |
GUILLORY PLUMBING & HEATING | P= | C | 12/21/2001 | | DARYL | DARYL | | P= | C | 2122552 |
GUILLORY PLUMBING & HEATING | P= | T | 12/20/2001 | PAID (REC#441325)locked at 4:45 | DOUGR | DOUGR | | P= | T | 2122545 |
GUILLORY PLUMBING & HEATING | P= | P | 12/13/2001 | h&c crossed tub and shower faucets, caulk tub spouts, floor drain strainer, unfinished basement | JEFF | JEFF | | P= | P | 2122539 |
GUILLORY PLUMBING & HEATING | PTO | C | 10/02/2001 | Contractor to fir out laundry wall and move pipes to avoid freeze issues and install non-corrosive anchors in closet flanges. | DARYL | DARYL | | PTO | C | 2122509 |