HOMEOWNER | B= | C | 07/09/2003 | | PHIL | PHIL | | B= | C | 2286909 |
HOMEOWNER | B= | R | 07/08/2003 | HOUSE NUMBERS NEED TO BE PERMANENT | JOND | JOND | | B= | R | 2286895 |
HOMEOWNER | B= | R | 07/08/2003 | ADDRESS NUMBERS ON HOUSE-2X4 CASING AT GARAGE ACCESS-INSULATION CERT-TEMPERED GLASS AT FRENCH DOORS STUDY | GREGC | GREGC | | B= | R | 2286902 |
HOMEOWNER | BFR | C | 01/23/2003 | | GREGC | GREGC | | BFR | C | 2286888 |
HOMEOWNER | BFR | P | 01/21/2003 | TILL NEED THE LATERALS AT THE TOP AND BOTTOM OF THEC2 TRUSS AND GUSSET CRIPPLE WALL BASEMENT | GREGC | GREGC | | BFR | P | 2286882 |
HOMEOWNER | BFR | P | 01/16/2003 | BACK BLOCKS AT OHD BRACKETS-LATERALS TOP AND BOTTOM C2-ADD 2X6 TRIMMERS UNDER BLOCKS THAT THE D TRUSSES ARE HUNG OFF OF-GUSSET CRIPPLE WALL BASEMENT-HAVE ALL THE ENG FOR ALL CORRECTIONS-OK TO INSULATE | GREGC | GREGC | | BFR | P | 2286876 |
HOMEOWNER | BSP | P | 01/15/2003 | ADDITIONAL PAD IN BASEMENT OK PER ENG-HAVE ENG | GREGC | GREGC | | BSP | P | 2286868 |
HOMEOWNER | BFR | T | 12/10/2002 | PAID (REC#494571)STOPPED INSPECTION AT MAIN LEVEL-DID THE ROOF-PLANS NEED TO GO BACK TO PLAN CHECK FOR REVISIONS THAT REFLECT ALL CHANGES -EXCLUSIONS- AND ADDITIONS-SEE BACK OF PERMIT CARD FOR CORRECTIONS NEEDED FOR THE PARTICAL INSPECTION DONE TO THIS POINT | GREGC | GREGC | | BFR | T | 2286862 |
HOMEOWNER | BFR | R | 12/09/2002 | THE TRUSS LAYOUR SHEET IS MISSING FRON THE PLANS-DID NOT DO INSPECTION-RECALL | GREGC | GREGC | | BFR | R | 2286854 |
HOMEOWNER | BLA | C | 11/22/2002 | | GREGC | GREGC | | BLA | C | 2286846 |
HOMEOWNER | BFD | C | 08/20/2002 | | GREGC | GREGC | | BFD | C | 2286837 |
HOMEOWNER | BFD | R | 08/16/2002 | 1. INSULATE FROST WALL 2. WRAP PIPES AT STEPS 3. EXPOSED ROCK | PHIL | PHIL | | BFD | R | 2286738 |
HOMEOWNER | BFN | C | 08/06/2002 | HAVE THE FOUNDATION DETAIL | GREGC | GREGC | | BFN | C | 2286830 |
HOMEOWNER | BFN | R | 08/05/2002 | NEED STAMPED COPY OF THE FOOTPRINT FOR THE FOUNDATION-LWI-FLOAT-BELOW GRADE LIVING | GREGC | GREGC | | BFN | R | 2286823 |
HOMEOWNER | BFT | C | 07/30/2002 | INCLUDES PADS | GREGC | GREGC | | BFT | C | 2286816 |
HOMEOWNER | BFT | R | 07/29/2002 | NEED THE FOUNDATION ENG FOR THE LAYOUT AND STEEL REQUIREMENTS | GREGC | GREGC | | BFT | R | 2286809 |
CASTLE ROCK ELECTRIC, INC. | E= | C | 07/01/2003 | | JERRY | JERRY | | E= | C | 2287038 |
CASTLE ROCK ELECTRIC, INC. | ES | C | 07/01/2003 | 3-WIRE UNDERGROUND,CASTLE ROCK ELECTRIC,NEW HOME | JERRY | JERRY | | ES | C | 2287045 |
CASTLE ROCK ELECTRIC, INC. | E= | T | 06/26/2003 | PAID (REC#519408)NOT READY,TOO MUCH TO LIST,COMPLETE REINSPECTION | JERRY | JERRY | | E= | T | 2287031 |
CASTLE ROCK ELECTRIC, INC. | ER | C | 11/22/2002 | unfinished basement | JERRY | JERRY | | ER | C | 2287017 |
CASTLE ROCK ELECTRIC, INC. | ES | R | 11/22/2002 | in sub and main panels i d netural and fill pvc with the homeruns,2ground rods required | JERRY | JERRY | | ES | R | 2287024 |
CASTLE ROCK ELECTRIC, INC. | EUG | C | 10/31/2002 | | JERRY | JERRY | | EUG | C | 2287013 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | C | 06/13/2003 | UNFINISHED BASEMENT, AC IS ONLY ROUGHED AT THIS TIME | DOUGR | DOUGR | | H= | C | 2287007 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | R | 06/09/2003 | AC LINE SET APPEARS TO BE BURIED IN WALL - CAN'T FIND, NEED 8' LADDER PROVIDED AT ATTIC ACCESS, REINSTAL RANGE GAS - RESUPPORT - RETEST HOUSE, COMPLETE AC IF BEING DONE ON THIS PERMIT | DOUGR | DOUGR | | H= | R | 2287000 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 12/05/2002 | | JEFF | JEFF | | HRR | C | 2286993 |
RIAL HEATING AND AIR CONDITIONING, INC. | HC | C | 12/05/2002 | | JEFF | JEFF | | HC | C | 2286986 |
HOMEOWNER | HI | C | 12/05/2002 | | JEFF | JEFF | | HI | C | 2286802 |
HOMEOWNER | HI | R | 12/04/2002 | waived trip fee as inspector was there for PTO also, low test, run 1'' all the way to attic furn | DOUGR | DOUGR | | HI | R | 2286788 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | R | 12/04/2002 | waived trip fee as inspector was there for PTO also, downdraft vent must be run in 8'' or 10'' per manufactures instructions | DOUGR | DOUGR | | HRR | R | 2286979 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | R | 11/27/2002 | must have range vent instructions - configuration won't work for many units, complete condensates & mark secondary, note - heat calcs ok | DOUGR | DOUGR | | HRR | R | 2286972 |
HOMEOWNER | HI | R | 11/27/2002 | sizing issues throughout - 400' collum | DOUGR | DOUGR | | HI | R | 2286773 |
HOMEOWNER | HI | R | 11/22/2002 | sizing issues throughout - meter at street, water heater stubbed to wrong location, permit not in sight | DOUGR | DOUGR | | HI | R | 2286759 |
RIAL HEATING AND AIR CONDITIONING, INC. | HD | R | 10/22/2002 | see HRR notes | JEFF | JEFF | | HD | R | 2286952 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRR | T | 10/22/2002 | PAID (REC#489016): trip fee, not ready, list to include but not limited to...approved set of plans, caps/jacks/collars, dryer vent?, remove fire stop at bvent main floor chase as to allow for inspection, repair insulation ac line set to attic, need proper reducer at attic furnace vent, support thermal duct per code, support duct per code, set and vent water heater, s-drives at top of return duct at panning?, need instructions for down draft....reinspect all | JEFF | JEFF | | HRR | T | 2286958 |
RIAL HEATING AND AIR CONDITIONING, INC. | HV | R | 10/22/2002 | see HRR notes | JEFF | JEFF | | HV | R | 2286965 |
DAVIS GAS SHOP INC | HO | C | 10/16/2002 | 350' of 2" yard line, 10 lb. test | JEFF | JEFF | | HO | C | 2286945 |
HOMEOWNER | P= | C | 07/03/2003 | | DOUGR | DOUGR | | P= | C | 2286938 |
HOMEOWNER | P= | R | 07/01/2003 | WAIVED TRIP FEE AS WAS ALREADY THERE FOR PTO+, STILL HAVE 2 TRAPS ON 1 TRAP ARM AT KITCHEN | DOUGR | DOUGR | | P= | R | 2286923 |
HOMEOWNER | PTO+ | C | 07/01/2003 | ADDED 2ND WH, CHECK GAS & VENT AT SAME TIME | DOUGR | DOUGR | | PTO+ | C | 2286930 |
HOMEOWNER | P= | R | 06/26/2003 | WATER HEATER ADDED AFTER INSPECTIONS - NEED TO PAY FOR ADDITIONAL INSPECTION & ALSO BLOCKED BY GAS LINE IN FRONT, CAN'T USE UNLISTED FLEX DRAIN CONNECTOR AT DISPOSAL, CAN'T HAVE 2 TRAPS ON 1 TRAP ARM AT KITCHEN, NEED ACCESSIBLE SHUT OFF FOR SHOWER HEAD IN CEILING THAT WAS ADDED - MUST BE ABLE TO TURN ON SHOWER VALVE WITHOUT BEING IN SPRAY | DOUGR | DOUGR | | P= | R | 2286915 |
HOMEOWNER | PTO | C | 12/04/2002 | | DOUGR | DOUGR | | PTO | C | 2286795 |
HOMEOWNER | PTO | R | 11/27/2002 | some trap arms still have more than 90 degrees, main level washer trap to close to outside wall, main level jetted tub full of water & frozen - may have broken pipes | DOUGR | DOUGR | | PTO | R | 2286780 |
HOMEOWNER | PTO | T | 11/22/2002 | PAID (REC#489036)not ready; not tested, too many elbows on trap arms, upstairs tub trap arm to long, too many fixture units on 2'' at east side of house, top of kitchen loop vent not done per code, vent future bar rough in basement, support to code, some vents lack proper grade, permit not in sight | DOUGR | DOUGR | | PTO | T | 2286766 |
HOMEOWNER | PWO | C | 10/28/2002 | | DALE | DALE | | PWO | C | 2286751 |
HOMEOWNER | PB | C | 08/29/2002 | 4", no water, wraps at PTO, need PWO | JEFF | JEFF | | PB | C | 2286745 |