COMMERCE CENTER COMMERCIAL BUILDERS, INC. | B= | C | 08/05/2003 | | RICK | RICK | | B= | C | 2314358 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | B= | P | 06/28/2003 | Temp CO: 1)STEPS AT ENTRY 2)VISQUEEN CRAWL SPACE 3)COMPLETE FIRE FINAL | ROLF | ROLF | | B= | P | 2314327 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | B= | P | 06/25/2003 | NEED FIRE FINAL | RICK | RICK | | B= | P | 2314350 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | B= | P | 05/19/2003 | 1)STEPS AT ENTRY 2)VISQUEEN CRAWL SPACE 3)COMPLETE FIRE FINAL | RICK | RICK | | B= | P | 2314343 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | BLA | C | 12/20/2002 | | RICK | RICK | | BLA | C | 2314321 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | BFR | C | 12/13/2002 | | RICK | RICK | | BFR | C | 2314314 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | BFR | R | 11/26/2002 | 1)Post address 2)Shim headers 3)Roll block hip monos 4)2 truss clips on "MHG1" 5)T-brace "H2","H3" and "H4" 6)Hanger 2x10 header to VL upper deck cover 7)Strap VL to corner post upper deck 8)Engineering for truss supporting furn 9)Squash blocks for deck columns 10)Door hdr supporting deck VL calls for 3-2x4 trimmers 11)Missing hanger on VL west side of stair hdr 12)Window east wall needs 4-2x6 trimmers 13)Glue shims 14)Squash blocks crawl spsce 15)Open hole | RICK | RICK | | BFR | R | 2314307 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | B16 | P | 11/12/2002 | Reviewed items for frame inspection | RICK | RICK | | B16 | P | 2314300 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | B16 | T | 11/11/2002 | PAID (REC#486744)FRAMING CONSULTATION | ANGELA | ANGELA | | B16 | T | 2314338 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | BFN | P | 09/26/2002 | Need copy of open hole, ok to pour | RICK | RICK | | BFN | P | 2314293 |
COMMERCE CENTER COMMERCIAL BUILDERS, INC. | BFT | C | 09/24/2002 | Post address | RICK | RICK | | BFT | C | 2314286 |
ROSS ELECTRIC-ENTERPRISE, INC. | E= | C | 05/16/2003 | GATE CONTROLLER ROUGH IN ONLY | TIMA | TIMA | | E= | C | 2314227 |
ROSS ELECTRIC-ENTERPRISE, INC. | EUG | C | 04/21/2003 | SIGN,FLAG POLE LIGHT,GATE CONTROLLER FEEDS OK | TIMA | TIMA | | EUG | C | 2314221 |
ROSS ELECTRIC-ENTERPRISE, INC. | E= | R | 03/05/2003 | TAKE TEMP WIRE OUT OF MAIN DISCONNECT,WIRE A/C UNITS | TIMA | TIMA | | E= | R | 2314216 |
ROSS ELECTRIC-ENTERPRISE, INC. | ES | C | 01/06/2003 | 200 amp 3/w ug ross electric | TIMA | TIMA | | ES | C | 2314208 |
ROSS ELECTRIC-ENTERPRISE, INC. | ES | R | 01/03/2003 | need water gec to go to neutral in main disconnect,loose bond bushing lug screw disconnect | TIMA | TIMA | | ES | R | 2314201 |
ROSS ELECTRIC-ENTERPRISE, INC. | ES | T | 12/12/2002 | PAID (REC#493164): TRIP-FEE PER TIMA @ 12-dec-2002 13:35:04 (NOT READY): not ready | TIMA | TIMA | | ES | T | 2314194 |
ROSS ELECTRIC-ENTERPRISE, INC. | ER | C | 11/25/2002 | | TIMA | TIMA | | ER | C | 2314186 |
ROSS ELECTRIC-ENTERPRISE, INC. | ER | R | 11/22/2002 | need hall outlet,protect romex attic access,re-identify white travellars 3-way switches | TIMA | TIMA | | ER | R | 2314179 |
O' DONNELL PLUMBING | H= | C | 05/16/2003 | | LYNNS | LYNNS | | H= | C | 2314386 |
HEADLEY MECH HGT & AIR COND | H= | C | 04/01/2003 | CORRECTIONS MADE. | LYNNS | LYNNS | | H= | C | 2314279 |
HEADLEY MECH HGT & AIR COND | H= | P | 03/28/2003 | NEED 1" CLEARANCE TO SHEET ROCK FROM B-VENT OFF WATER HEATER FROM WALL AND THROUGH WALL AND CEILING, NEED SCREENS IN BOTH BATH FAN CAPS. | LYNNS | LYNNS | | H= | P | 2314272 |
HEADLEY MECH HGT & AIR COND | HC | C | 11/26/2002 | OK to release meter. | LYNNS | LYNNS | | HC | C | 2314250 |
HEADLEY MECH HGT & AIR COND | HD | C | 11/26/2002 | Rough duct complete. | LYNNS | LYNNS | | HD | C | 2314257 |
HEADLEY MECH HGT & AIR COND | HV | C | 11/26/2002 | Water heater vent complete. | LYNNS | LYNNS | | HV | C | 2314264 |
HEADLEY MECH HGT & AIR COND | HV | P | 11/19/2002 | Water heater not vented yet. 2- furnaces and 4- bath fans complete. Will check fireplace termination after stucco. | LYNNS | LYNNS | | HV | P | 2314243 |
HEADLEY MECH HGT & AIR COND | HD | P | 11/19/2002 | Need to insulate the boots and plenum in the attic. | LYNNS | LYNNS | | HD | P | 2314237 |
O' DONNELL PLUMBING | HI | C | 11/18/2002 | 10# test and design per approved plans. | LYNNS | LYNNS | | HI | C | 2314379 |
O' DONNELL PLUMBING | P= | C | 04/22/2003 | | JACK | JACK | | P= | C | 2314400 |
O' DONNELL PLUMBING | P= | P | 04/15/2003 | ARTICLE 412.6 LAST SENTENCE 22'' MINUMUM DOOR ON SHOWER AND NEED SUPPORT ON EXPANSION TANK | JACK | JACK | | P= | P | 2314393 |
O' DONNELL PLUMBING | PTO | C | 11/07/2002 | | JACK | JACK | | PTO | C | 2314371 |
O' DONNELL PLUMBING | PTO | P | 11/05/2002 | need commercial grade self draining hosebibbs, handicap comode to close to wall and lost test on dwv | JACK | JACK | | PTO | P | 2314363 |