MARTINSON CONSTRUCTION, LLC | B= | C | 01/29/2003 | | LEEG | LEEG | | B= | C | 2387618 |
MARTINSON CONSTRUCTION, LLC | BFR | C | 01/27/2003 | | LEEG | LEEG | | BFR | C | 2387613 |
MARTINSON CONSTRUCTION, LLC | B= | P | 01/27/2003 | Need electrical, mechanical and fire final inspections / Need sign front door "This door to remain unlocked during business hours" / Need tactile sign for handicap bathroom. | LEEG | LEEG | | B= | P | 2387612 |
MARTINSON CONSTRUCTION, LLC | BFR | P | 12/27/2002 | Need electrical inspection. All else okay. | LEEG | LEEG | | BFR | P | 2387603 |
MANITOU ELECTRIC, LLC | E= | C | 01/28/2003 | SUPPORT J-BOX ON ROOF, GROUND DISCONNECTS | MIKEC | MIKEC | | E= | C | 2387648 |
MANITOU ELECTRIC, LLC | E= | T | 01/27/2003 | PAID (REC#496313)LIGHT TRACK NOT SUPPORTED PROPERLY, OUTLETS IN KITCHEN STILL NOT GFI PROTECTED, ROOF ACCESS NOT PROVIDED AS REQUESTED???, STILL NEED ACCESS TO TOP OF COOLER UNITS | TERRY | TERRY | | E= | T | 2387646 |
MANITOU ELECTRIC, LLC | E= | R | 01/24/2003 | SUPPORT WIRES LIGHT TRAK. ROOF INSPECTION NEED LADDER. INSPECTION TOP OF COOLERS, GFI ON ALL KITCHEN 120 VOLT OUTLETS. | IKE | IKE | | E= | R | 2387644 |
MANITOU ELECTRIC, LLC | ER | C | 01/21/2003 | ceiling | MIKEC | MIKEC | | ER | C | 2387642 |
MANITOU ELECTRIC, LLC | ES | C | 01/09/2003 | 3ph 4w 120/208v 400 amp c-t metered service from gutter. manitou elec | MIKEC | MIKEC | | ES | C | 2387640 |
MANITOU ELECTRIC, LLC | ER | P | 12/27/2002 | walls ok'd | TERRY | TERRY | | ER | P | 2387638 |
MARTINSON CONSTRUCTION, LLC | H= | C | 01/28/2003 | | JOHNW | JOHNW | | H= | C | 2387616 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | C | 01/28/2003 | | JOHNW | JOHNW | | H= | C | 2387629 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | P | 01/24/2003 | NEED BALANCE REPORT AND INNERLOCK FAN | JOHNW | JOHNW | | H= | P | 2387636 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HD | C | 01/23/2003 | | JOHNW | JOHNW | | HD | C | 2387634 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HD | P | 01/21/2003 | SEAL 16" X 16" AND 6" ROUND EXHAUSTS. 12" & 16" FLEX DUCT NOT TO CODE - TOO TIGHT OF BENDING RADIUS. UNABLE TO VERIFY CLASS RATING OF GREY 16" FLEX. SEAL ALL "S" & DRIVE JOINTS ON SUPPLY AND RETURN. NOTE: DISHWASHER EXHAUST MATERIAL AND JOINTS NOT PER PLAN, BUT MEET CODE MINIMUM. | BOB | BOB | | HD | P | 2387632 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HV | C | 01/10/2003 | WATERHEATER VENT | JOHNW | JOHNW | | HV | C | 2387627 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HC | C | 01/10/2003 | SET METER | JOHNW | JOHNW | | HC | C | 2387624 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HD | P | 01/10/2003 | | JOHNW | JOHNW | | HD | P | 2387626 |
MARTINSON CONSTRUCTION, LLC | HI | C | 12/31/2002 | 60 psi / check for regulators at meter set | JOHNW | JOHNW | | HI | C | 2387610 |
MARTINSON CONSTRUCTION, LLC | HI | P | 12/27/2002 | 2- 10# tests on low pressure risers OK. | LYNNS | LYNNS | | HI | P | 2387608 |
MARTINSON CONSTRUCTION, LLC | P= | C | 01/24/2003 | | LEE | LEE | | P= | C | 2387622 |
MARTINSON CONSTRUCTION, LLC | PTO | C | 12/27/2002 | | JACK | JACK | | PTO | C | 2387605 |
MARTINSON CONSTRUCTION, LLC | PB | C | 12/12/2002 | Plumber will add 3- comp sink and hand sink to permit, 2" dry vent for w/c to be accessable at final (behind toilet) | LEE | LEE | | PB | C | 2387602 |