EMBREE CONSTRUCTION GROUP, INC | B= | P | 09/06/2003 | Temp CO: WAITING ON FIRE | ROLF | ROLF | | B= | P | 2487876 |
EMBREE CONSTRUCTION GROUP, INC | B= | C | 08/06/2003 | | DANF | DANF | | B= | C | 2487907 |
EMBREE CONSTRUCTION GROUP, INC | BSP | T | 08/01/2003 | PAID (REC#525048)ADDITIONAL PLAN REVIEW TIME: $40.000 FROM: BOB REVISED MECHANICAL DUCTWORK | BOB | BOB | | BSP | T | 2487902 |
EMBREE CONSTRUCTION GROUP, INC | B= | R | 07/31/2003 | 1) FIRE FINAL 2) HEAT FINAL 3) DOR TO REMAIN UNLOCKED SIGN ABOVE FRONT DOOR 4) REMOVE DEADBOLT FROM MEN'S ROOM LOCKER ROOM EXIT DOOR 5) BOTTOM RISE FROM SPINNING ROOM EXIT GREATER THEN 7" AND LANDING LESS THEN 44" AND PATH TO PUBLIC WAY | DANF | DANF | | B= | R | 2487899 |
DAVIS PLUMBING AND GAS | BSP | T | 07/01/2003 | PAID (REC#524158)ADDITIONAL PLAN REVIEW TIME: $40.000 FROM: RUSSELL GAS PIPING TO NEW GRND MTD RTU, REVISING EXISTING GAS PIPING | RUSSELL | RUSSELL | | BSP | T | 2487800 |
EMBREE CONSTRUCTION GROUP, INC | BFR | P | 06/19/2003 | NEED ELECTRICAL/PLUMBING/HEAT INSPECTIONS
| MIKE | MIKE | | BFR | P | 2487894 |
EMBREE CONSTRUCTION GROUP, INC | BFR | P | 06/18/2003 | NEED PLUMBING/ELECTRICAL/HEAT INSPECTIONS,FIRESTOP
| MIKE | MIKE | | BFR | P | 2487891 |
EMBREE CONSTRUCTION GROUP, INC | BFR | P | 06/05/2003 | SEE PLANS FOR AREA INSPECTED | TERRYB | TERRYB | | BFR | P | 2487886 |
EMBREE CONSTRUCTION GROUP, INC | BSP | T | 06/03/2003 | PAID (REC#515288): ADDITIONAL PLAN REVIEW TIME: $40.000 From: RUSSELL Added outdoor ground mounted RTU, still need gas piping plan | RUSSELL | RUSSELL | | BSP | T | 2487883 |
EMBREE CONSTRUCTION GROUP, INC | BFR | R | 06/03/2003 | NOT READY
| MIKE | MIKE | | BFR | R | 2487879 |
RED ROCK ELECTRIC, INC | E= | C | 07/11/2003 | | GARYL | GARYL | | E= | C | 2487863 |
RED ROCK ELECTRIC, INC | ER | P | 07/01/2003 | MAIN ROOM CEILING OK TO CLOSE | GARYL | GARYL | | ER | P | 2487858 |
RED ROCK ELECTRIC, INC | ER | P | 06/26/2003 | WOMENS , MENS, BICYCLE, AROBICS, WALLS AND CEILINGS OK TO CLOSE | GARYL | GARYL | | ER | P | 2487855 |
RED ROCK ELECTRIC, INC | ER | P | 06/18/2003 | CYCLE RM, LOCKER AND BATHRMS, WALLS AND PARTIAL CEILING OK TO CLOSE, ALSO WREAK OUT OLD WIRING | GARYL | GARYL | | ER | P | 2487851 |
RED ROCK ELECTRIC, INC | ER | P | 06/04/2003 | WALLS OK'D FOR SHEETROCK | GARYL | GARYL | | ER | P | 2487847 |
PIKES PEAK SHEET METAL | H= | C | 08/06/2003 | | JON | JON | | H= | C | 2487939 |
PIKES PEAK SHEET METAL | H= | P | 08/05/2003 | NO T&P PIPING ON EITHER WATER HEATER. SECTIONS OF B-VENT RUNNING WRONG DIRECTION. NEEDS PROPER SLOPE ON WATER HEATER VENT CONNECTORS. NEEDS COMMON VENTING SUPPORTED ON WATER HEATER'S. NEEDS ALL B-VENT JOINTS SECURED PROPERLY AND TO HAVE SCREWS TO SECURE VENT CONNECTORS AT BOTH DRAFT DIVERTERS. | JON | JON | | H= | P | 2487934 |
PIKES PEAK SHEET METAL | H= | P | 08/04/2003 | NEEDS VENT PERMIT AND INSPECTION, AT WATER HEATER REPLACEMENT X2. | JON | JON | | H= | P | 2487931 |
HAYNES MECHANICAL SYSTEMS, INC. | H= | C | 08/04/2003 | | JON | JON | | H= | C | 2487871 |
HAYNES MECHANICAL SYSTEMS, INC. | H= | P | 07/31/2003 | NEEDS APPROVED PLANS ON SITE SHOWING NEW 20 TON UNIT AND DUCT CONNECTIONS INSIDE AND OUT. NEVER GOT HD COMPLETE FOR 2O TON DUCT CONNECTIONS, ALSO DEMO WORK FROM EXISTING 30 TON UNIT. NEEDS CEILING TILE REMOVED FOR INSPECTIONS. NEEDS ADDED DUCT SUPPORT AT 20 TON UNIT OUTSIDE. NEED TO PROTECT 20 TON UNIT AT DRIVE WAY AREA FROM PHYSICAL DAMAGE. 20 TON UNIT DUCT WORK NOT SEALED WEATHER TIGHT INTO BUILDING. REST OK. | JON | JON | | H= | P | 2487866 |
PIKES PEAK SHEET METAL | H= | P | 07/31/2003 | NEEDS APPROVED PLANS ON SITE SHOWING NEW 20 TON UNIT AND DUCT CONNECTIONS INSIDE AND OUT. NEVER GOT HD COMPLETE FOR 2O TON DUCT CONNECTIONS, ALSO DEMO WORK FROM EXISTING 30 TON UNIT. NEEDS CEILING TILE REMOVED FOR INSPECTIONS. NEEDS ADDED DUCT SUPPORT AT 20 TON UNIT OUTSIDE. NEED TO PROTECT 20 TON UNIT AT DRIVE WAY AREA FROM PHYSICAL DAMAGE. 20 TON UNIT DUCT WORK NOT SEALED WEATHER TIGHT INTO BUILDING. REST OK. | JON | JON | | H= | P | 2487926 |
DAVIS PLUMBING AND GAS | H= | C | 07/30/2003 | GAS CONTRACTOR ONLY. | JON | JON | | H= | C | 2487813 |
DAVIS PLUMBING AND GAS | HI | C | 07/30/2003 | GAS COMPLETE TO GROUND LEVEL PAKAGE UNIT. 10 LB TEST. | JON | JON | | HI | C | 2487816 |
PIKES PEAK SHEET METAL | H= | R | 07/15/2003 | NEEDS PROPER PLANS ON JOB, FOR ENTIRE JOB, STILL HAVE NOT VIEWED APPROVED PLANS FOR NEW 20 TON UNIT AND DUCT WORK, THAT SHOW TIE IN AND DEMO WORK FOR SOUTH EXPOSED SPRIAL DUCTWORK. WENT OVER THIS WITH BUILDING JOB SUPER PREVIOUS TO THIS INSPECTION. NO ONE ON SITE FROM PIKES PEAK SHEET METAL. | JON | JON | | H= | R | 2487923 |
DAVIS PLUMBING AND GAS | HI | P | 07/14/2003 | 60 LB TEST ENTIRE LOOP (WELDED) ADDED 2- NEW WATER HEATERS, 1- NEW ROOF TOP, 1- NEW GROUND PACKAGE UNIT. PROPER PERMITS FOR ALL HVAC EQUIPMENT AND DUCT WORK WATER HEATER'S, WITH PROPER INSPECTIONS. RECALL HI FOR GROUND UNIT WHEN READY, AND ALL FINAL CONNECTIONS TO APPLIANCES FOR FINAL. | JON | JON | | HI | P | 2487808 |
DAVIS PLUMBING AND GAS | HI | R | 07/10/2003 | NO ONE ON SITE 5:00. COULD NOT FIND APPROVED PLANS. RECALL. | JON | JON | | HI | R | 2487805 |
PIKES PEAK SHEET METAL | HD | P | 06/26/2003 | MEN'S AND WOMEN'S LOCKER ROOMS OK TO COVER. | LYNNS | LYNNS | | HD | P | 2487915 |
PIKES PEAK SHEET METAL | HRR | R | 06/26/2003 | THIS IS NOT AN HRR INSPECTION, SHOULD BE HD COMMERCIAL. | LYNNS | LYNNS | | HRR | R | 2487919 |
PIKES PEAK SHEET METAL | HD | P | 06/19/2003 | KID'S ROOM AND AROBIC AREA OK TO COVER. | LYNNS | LYNNS | | HD | P | 2487910 |
WRIGHT PLBG. & HTG. CO.,INC. | P= | C | 07/16/2003 | | JACK | JACK | | P= | C | 2487844 |
WRIGHT PLBG. & HTG. CO.,INC. | PTO | C | 06/27/2003 | | JACK | JACK | | PTO | C | 2487838 |
WRIGHT PLBG. & HTG. CO.,INC. | PTO | P | 06/20/2003 | MENS AND WOMENS RESTROOMS AND LOCKER ROOMS OK EXCEPT FOR WOMENS HANDICAP TOILET TO FAR FROM WALL, FIX BY FINAL | JACK | JACK | | PTO | P | 2487834 |
WRIGHT PLBG. & HTG. CO.,INC. | PTO | P | 06/09/2003 | LACKING RESTROOMSAND LOCKER ROOMS | JACK | JACK | | PTO | P | 2487830 |
WRIGHT PLBG. & HTG. CO.,INC. | PB | P | 06/05/2003 | MENS AND WOMENS RESTROOMS, LOCKER ROOMS AND SAUNAS | JACK | JACK | | PB | P | 2487824 |
WRIGHT PLBG. & HTG. CO.,INC. | PB | P | 05/30/2003 | OFFICE AND KIDS RESTROOMS, BACK WALL DRINKING FOUNTAINS | JACK | JACK | | PB | P | 2487821 |