HOLLADAY BROTHERS CONSTRUCTION, INC | B= | C | 05/04/2004 | | MIKE | MIKE | | B= | C | 2554867 |
HOLLADAY BROTHERS CONSTRUCTION, INC | B= | P | 04/23/2004 | UNABLE TO INSPECT FINAL GRADE(SNOW)
| MIKE | MIKE | | B= | P | 2554863 |
HOLLADAY BROTHERS CONSTRUCTION, INC | B= | T | 03/23/2004 | PAID (REC#567152)PROBLEMS NOT CORRECTED(SMOKE DETECTOR IN HALL OUTSIDE NEW BEDROOM MUST BE HARD WIRED & INTERCONNECTED),REVIEWED GRADING PROBLEMS WITH HOMEOWNER(NO CONTRACTOR ONSITE EVEN AFTER 30 MINUTE CALL AHEAD) | MIKE | MIKE | | B= | T | 2554859 |
HOLLADAY BROTHERS CONSTRUCTION, INC | B= | T | 03/11/2004 | PAID (REC#560801)BEDROOM SMOKE DETECTORS & FINAL GRADE NOT COMPLETE | MIKE | MIKE | | B= | T | 2554855 |
HOLLADAY BROTHERS CONSTRUCTION, INC | B= | R | 02/10/2004 | 1) MISSING SMOKE ALARMS IN ALL BEDROOMS 2) NEED 18" TREAD OUTSIDE SLIDER 3) SEAL AROUND GAS STUB OUT NORTH WALL 4) FINAL GRADE | DANF | DANF | | B= | R | 2554847 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFR | C | 02/10/2004 | | DANF | DANF | | BFR | C | 2554851 |
HOLLADAY BROTHERS CONSTRUCTION, INC | B= | R | 02/09/2004 | NEED COMPLETED FRAME INSPECTION, NO FINAL INSPECTION PERFORMED
| MIKE | MIKE | | B= | R | 2554843 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BLA | C | 12/02/2003 | | MIKE | MIKE | | BLA | C | 2554839 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BLA | R | 12/01/2003 | PERMIT COVERS ADDITION ONLY,NEED SEPARATE PERMIT FOR DETACHED GARAGE & STUCCO EXISTING RESIDENCE
| MIKE | MIKE | | BLA | R | 2554835 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFR | P | 11/21/2003 | OK TO INSULATE; 1) HEADER AT C/S DOES NOT SUPORT JOISTS AND NO HANGERS 2) NEED C/S VENT IN C/S COVER ON SIDE 3) KICKER LATERAL BRACING END DINING ROOM | DANF | DANF | | BFR | P | 2554831 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFR | R | 11/19/2003 | 1) BRACE GABLE MBED AT TOP PLATE/CEILING AND STRAP PEAK 2) FIRESTOP LAUNDRY WALL 3) SHIM MBED HEADER SOUTH WALL AND TOP PLATE 4) BRACE ENST END OF TRUSS LATERAL BRACING 5) POST OVERFRAME SOUTH OF RIDGE 48" OC TO RAFTERS 6) LEG DOWN RIDGE BEAM AND POST END 7) SIZE KITCHEN HEADER AND CRAWSPACE ACCESS HEADER 8) TRUSSES NOT BEARING ON EXISTING FDN BUT ON NEW FLOOR JOISTS AT INTERIOR BEARING WALLS 9) MISSING GIRDER TRUSSES, HENCE THE WALL UNDER IS OFF FDN 10) C/S VENTS | DANF | DANF | | BFR | R | 2554827 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFN | C | 11/12/2003 | RECEIVED LETTER FROM COLORADO ENGINEERING(29932) INDICATING FILL MATERIAL BETWEEN NEW & EXISTING FOUNDATION WALL SYSTEM OK AS COMPLETED
| MIKE | MIKE | | BFN | C | 2554823 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFT | C | 11/06/2003 | RECEIVED LETTER FROM COLORADO ENGINEERING(29932) FOR REVISED FOUNDATION DESIGN @ EXISTING FOUNDATION WALL
| MIKE | MIKE | | BFT | C | 2554819 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFN | P | 11/06/2003 | NEED COMPACTION TEST REPORT FOR FILL MATERIAL BETWEEN EXISTING FOUNDATION SYSTEM & NEW FOUNDATION WALL
| MIKE | MIKE | | BFN | P | 2554815 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BSP | T | 10/06/2003 | PAID (REC#535956)ADDITIONAL PLAN REVIEW TIME: $40.000 From: RONW Ken Atkins = changes to #E81651 = okay | RONW | RONW | | BSP | T | 2554811 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFN | P | 09/26/2003 | PADS OK; NEED REVISED DESIGN FOR WALL MOVED 20" FROM EXISTING FOUNDATION; OLD DESIGN, AND LETTERS ON FILE; DRAIN, USEABLE | DANF | DANF | | BFN | P | 2554807 |
HOLLADAY BROTHERS CONSTRUCTION, INC | BFT | P | 09/23/2003 | NEED REVISED DESIGN FOR FOUNDATION WALL @ EXISTING HOUSE,NEED TO INSPECT INTERIOR PADS
| MIKE | MIKE | | BFT | P | 2554768 |
CHERRY VALLEY ELECTRIC | E= | C | 03/10/2004 | CORRECTIONS MADE | GARYL | GARYL | | E= | C | 2554934 |
CHERRY VALLEY ELECTRIC | E= | R | 02/03/2004 | 20AMP UNIT, 2-POLE BRKER INSTALLED FOR JET TUB
NEED A RE-INSPECTION ON RESIDENCE, REJECT ISSUED 2/19
| GARYL | GARYL | | E= | R | 2554928 |
CHERRY VALLEY ELECTRIC | E= | T | 01/13/2004 | PAID (REC#553619): OUT LET WAS MOVED TO WHERE IT IS ACCESSIBLE, 2-CIRCUITS GOING TO RECEPT-SAME YOKE AND NEEDS A COMMON TRIP ON BOTH CIRCUITS | GARYL | GARYL | | E= | T | 2554923 |
CHERRY VALLEY ELECTRIC | E= | R | 01/06/2004 | RECEPT'S (2) FOR JACUZZI MUST BE ACCESSIBLE | GARYL | GARYL | | E= | R | 2554919 |
CHERRY VALLEY ELECTRIC | ER | C | 11/18/2003 | CORRECTIONS MADE | GARYL | GARYL | | ER | C | 2554915 |
CHERRY VALLEY ELECTRIC | ER | R | 11/17/2003 | 1) JACUZZI RECEPT NEEDS TO BE ACCESSIBLE, GFI UNITS NEED TO BE BLANK FACED AND REMOTELY LOCATED 2) 4-12/2'S IN CLOSET AREA NEED STACKER | GARYL | GARYL | | ER | R | 2554912 |
CHERRY VALLEY ELECTRIC | ES | C | 09/23/2003 | 3-WIRE OVERHEAD, SERVICE RELOCATION AND UP-GRADE, POSSIBLE NEW DROP, CHERRY VALLEY ELECT | GARYL | GARYL | | ES | C | 2554908 |
CHERRY VALLEY ELECTRIC | ES | T | 09/18/2003 | PAID (REC#533444): NO ONE HOME 9:55 AM | GARYL | GARYL | | ES | T | 2554904 |
ROCKY MTN. CONSTRUCTION ASSOC. | H= | C | 02/06/2004 | | JON | JON | | H= | C | 2554900 |
ROCKY MTN. CONSTRUCTION ASSOC. | H= | P | 02/03/2004 | NEED INSTALLATION INSTRUCTIONS FOR THE BRAND OF CSST USED, FOR NAIL PROTECTION IN 3 1/2'' WALLS, LEAVE EXPOSED. | JON | JON | | H= | P | 2554896 |
A & Z MECHANICAL, INC. | H= | C | 01/28/2004 | LOUVERED DOOR. | MARTY | MARTY | | H= | C | 2554946 |
A & Z MECHANICAL, INC. | H= | R | 01/02/2004 | NO FINAL TILL INSIDE GAS ISSUE IS RESOLVED. | MARTY | MARTY | | H= | R | 2554942 |
ROCKY MTN. CONSTRUCTION ASSOC. | H= | T | 12/08/2003 | PAID (REC#553666)CONTRACTOR DID NOT CALL REINSPECTION FOR INSIDE GAS LINE AND NOW IS ALL CONSEALED. NAIL PROTECTION TO BE TO CSST MANUFACTURE SPEC'S WHEN EXPOSED AND INSPECTED. | JON | JON | | H= | T | 2554892 |
ROCKY MTN. CONSTRUCTION ASSOC. | HI | R | 11/19/2003 | TEST OK NEED NAIL PROTECTION ON WALL BY TRUSSES. | MARTY | MARTY | | HI | R | 2554888 |
ROCKY MTN. CONSTRUCTION ASSOC. | H= | R | 11/19/2003 | WHEN HI COMPLETED. | MARTY | MARTY | | H= | R | 2554884 |
A & Z MECHANICAL, INC. | HRR | C | 11/07/2003 | UPDATE DETAIL FIXTURE LIST TO SHOW ALL RESIDENTIAL DUCTS, DRYER VENT, BATH EXHAUST AND NEW COMMON B-VENT, NOTE: AC ROUGH-IN ONLY AT THIS TIME | LEE | LEE | | HRR | C | 2554938 |
AFFORDABLE PLUMBING & HEAT,INC | P= | C | 12/24/2003 | | MARTY | MARTY | | P= | C | 2554880 |
AFFORDABLE PLUMBING & HEAT,INC | P= | R | 12/23/2003 | LEAK UNDER W/CLOSET,WATER NOT HOT,LEAK UNDER LAV. | MARTY | MARTY | | P= | R | 2554875 |
AFFORDABLE PLUMBING & HEAT,INC | PTO | C | 11/17/2003 | NEED PUMP ACCESS AT REAR ON FINAL. | MARTY | MARTY | | PTO | C | 2554871 |