MEMORIAL HOSPITAL | H02 | C | 04/25/2024 | NO VISIT MADE DUE TO H06 SCHEDULED IN MAY (Receipt #2057228) | ROBERTV | ROBERTV | | H02 | C | 8064492 |
MEMORIAL HOSPITAL | H01 | C | 10/26/2023 | 5 YEAR 4/19 -- ANNUAL 6/23 -- OTIS W/ TKE SERVICE -- NOTE: MONITOR ROPES FOR DIAMETERS (Receipt #2002492) | BENH | BENH | | H01 | C | 7901061 |
MEMORIAL HOSPITAL | HE16 | C | 06/01/2023 | ELEVATOR RECEIVED A RED TAG NOTIFICATION DUE TO THE CATEGORY 1 TESTING BEING OVER 60 DAYS PAST DUE. ELEVATORS SCHEDULED TO BE REMOVED FROM SERVICE ON 6/16/23. (cat 1 -- 6/23, red tag removed, DS) | DUSTINS | DUSTINS | | HE16 | C | 7760031 |
MEMORIAL HOSPITAL | H02 | C | 04/28/2023 | H02 -- 5 YEAR 4/19 -- ANNUAL 3/22 -- OTIS W/ TKE SERVICE -- / PPRBD RECORDS INDICATE ANNUAL TRACTION SAFETY TESTING IS PAST DUE, 30 DAYS PROVIDED FOR ANNUAL SAFETY TESTING TO BE COMPLETED TO AVOID RED TAG AND POSSIBLE SERVICE INTERRUPTION | DUSTINS | DUSTINS | | H02 | C | 7729986 |
MEMORIAL HOSPITAL | H01 | C | 10/31/2022 | ANNUAL 3/22 -- OTIS W/ TKE SERVICE -- NEED TO ADD FLAGS ON FASCIA BETWEEN 1ST & 2ND FLOOR -- (Receipt #1910844) | BENH | BENH | | H01 | C | 7566965 |
MEMORIAL HOSPITAL | H02 | C | 04/25/2022 | HO2--5YR 04/2019-- ANNUAL 03/2022-- OTIS WITH TKE SERVICE AND LOCKBOX | MIKEM | MIKEM | | H02 | C | 7350759 |
MEMORIAL HOSPITAL | H01 | C | 10/18/2021 | 5YR 04/2019-- ANNUAL 03/2021-- OTIS WITH TKE SERVICE AND LOCKBOX--/ PROVIDE UP TO DATE MONTHLY FIRE EMERGENCY OPERATORS LOG (Receipt #1815689) (cat 1 -- 3/2022) | MIKEM | MIKEM | | H01 | C | 7145609 |
MEMORIAL HOSPITAL | HE16 | C | 08/16/2021 | PERFORMED FOLLOW-UP INSPECTIONS: TRAVELING CABLES HAVE BEEN REPLACED....EMERGENCY PHONE STILL NOT WORKING.--- ELEVATOR HAS BEEN SCHEDULED TO BE REMOVED FROM SERVICE 8/31/2021 (Emergency phone is fixed and working per onsite inspection RV) | ROBERTV | ROBERTV | | HE16 | C | 7073414 |
MEMORIAL HOSPITAL | H02 | C | 04/26/2021 | 5YR -- 4/19 -- CAT1 -- 3/21 -- OTIS W/ TKE SERVICE. TRAVELING CABLE SHEATHING CONDITIONS AND REPAIRS CONTINUE TO WORSEN. TRAVELING CABLES NEED REPLACED. ELEVATOR EMERGENCY PHONE NOT WORKING AGAIN. | ROBERTV | ROBERTV | | H02 | C | 6947691 |
MEMORIAL HOSPITAL | H01 | C | 10/22/2020 | 5YR -- 4/19 -- CAT1 --1/20 -- OTIS W/ TKE LOCKBOX AT TOP OF STAIRS. COULD NOT ESTABLISH TWO-WAY COMMUNICATION ON ELEVATOR PHONE EVEN AFTER MULTIPLE ATTEMPTS. EMERGENCY LIGHTS AND ALARM BELL NOT WORKING. CAB MOUNTED DIRECTIONAL INDICATOR IS NOT SOUNDING WHEN CAR ARRIVES AT FLOOR. TRAVELING CABLE CONDITION HAS BECOME VERY POOR IN AREAS WHERE REPAIRS HAVE BEEN ALREADY MADE. NEED QUARTERLY EMERGENCY PHONE AND FIRE SERVICE TESTING LOGS ONSITE. (Receipt #1723934) (Update: Elevator phones have been ordered, traveling cables replacements are still questionable 1/22/2021 RV) | ROBERTV | ROBERTV | | H01 | C | 6751899 |
MEMORIAL HOSPITAL | H02 | C | 04/02/2020 | 5 YEAR 4/19, CAT 1 1/20, OTIS, TKE LOCKBOX, HO2 | ERIC | ERIC | | H02 | C | 6530188 |
MEMORIAL HOSPITAL | H01 | C | 10/22/2019 | 5YR 4/19--OTIS W/ TKE SERVICE & LOCKBOX--RBD NOTE: (MONITOR TRAVELING CABLE SHEATHING FOR CRACKS) (Receipt #1639117) | CALE | CALE | | H01 | C | 6375959 |
MEMORIAL HOSPITAL | H02 | C | 04/11/2019 | WITNESSED 5YR TRACTION SAFETY TEST W/ TKE 04/10/19 | CALE | CALE | | H02 | C | 6162293 |
MEMORIAL HOSPITAL | H06 | C | 04/11/2019 | WITNESSED 5YR TRACTION SAFETY TEST W/ TKE 04/10/19--OTIS W/ TKE LOCKBOX--TRAVELING CABLE SHEATHING IS CRACKING (Receipt #1589384) | CALE | CALE | | H06 | C | 6162290 |
MEMORIAL HOSPITAL | H01 | C | 10/03/2018 | 5YR -- 2/14 -- ANNUAL 10/17 -- OTIS W/ TKE LOCKBOX. TRAVELING CABLE SHEATHING IS CRACKING (Receipt #1543754) | ROBERTV | ROBERTV | | H01 | C | 5983877 |
MEMORIAL HOSPITAL | H02 | C | 04/17/2018 | 5YR 2/14- OTIS, TKE SERVICE, HO2 | ERIC | ERIC | | H02 | C | 5819034 |
MEMORIAL HOSPITAL | H01 | C | 10/09/2017 | 5YR -- 2/14 -- OTIS W/ TKE SERVICE. REQUIRED ANNUAL CATEGORY 1 TESTING HAS YET TO BE PERFORMED AND MUST BE COMPLETED BY 10/31/2017........... ALSO, CAB DOOR RESTRICTOR BAR DOES NOT ENGAGE WITH ANY HOISTWAY DOOR RESTRICTOR FLAGS | ROBERTV | ROBERTV | | H01 | C | 5648885 |
MEMORIAL HOSPITAL | H02 | C | 04/10/2017 | 5 YEAR 2/14 OTIS. TKE SERVICE AND LOCKBOX KEYS FOR ALL. NEED ANNUAL INSPECTION TEST TAGS AND INSPECTION FORMS | ERIC | ERIC | | H02 | C | 5470270 |
MEMORIAL HOSPITAL | H01 | C | 10/21/2016 | 5 YEAR 2/14 OTIS, TKE SERVICE AND LOCKBOX. NEED ANNUAL TEST TAG AND FORM (Receipt #1374431) | ERIC | ERIC | | H01 | C | 5324396 |
MEMORIAL HOSPITAL | H02 | C | 04/26/2016 | H02 | ROBERTV | ROBERTV | | H02 | C | 5184450 |
MEMORIAL HOSPITAL | H01 | C | 10/30/2015 | 5YR -- 2/14 -- OTIS W/ TKE LOCKBOX. DOOR RESTRICTOR AT TOP FLOOR NOT WORKING, MISSING CATEGORY 1 TEST FORM AND TAG FOR 2/2015 (Receipt #1296494) | ROBERTV | ROBERTV | | H01 | C | 5069257 |
MEMORIAL HOSPITAL | H02 | C | 04/30/2015 | 5 YEAR 2/14 OTIS TKE SERVICE. SUSPENSION ROPES REPLACED. HO2 | ERIC | ERIC | | H02 | C | 4946957 |
MEMORIAL HOSPITAL | HE16 | C | 02/03/2015 | INSPECTION OF ROPES INDICATE WEAR AND BREAKAGE BEYOND NORMAL CONDITIONS PER ASME A17.6-2010 - ITEM 1.10.12 (c). ROPES NEED REPLACED AS SOON AS POSSIBLE AND ALSO FREQUENT MONITORING OF ROPES REQUIRED UNTIL REPLACEMENT PERFORMED | ROBERTV | ROBERTV | | HE16 | C | 4895725 |
MEMORIAL HOSPITAL | H01 | C | 10/21/2014 | 5YR 2-14 OTIS (Receipt #1227720) | TOM | TOM | | H01 | C | 4839372 |
MEMORIAL HOSPITAL | H02 | C | 04/14/2014 | WITNESSED 2/14 | ERIC | ERIC | | H02 | C | 4720036 |
MEMORIAL HOSPITAL | H06 | C | 02/05/2014 | WITNESSED 5 YEAR SAFETY INSPECTION. NEED CALL STATION FIRE SIGNS AT ALL LANDINGS. (IN CASE OF FIRE DO NOT USE ELEVATOR USE STAIRS) (Receipt #1178412) | ERIC | ERIC | | H06 | C | 4684333 |
MEMORIAL HOSPITAL | H01 | C | 10/17/2013 | 5YRN 4-11-OTIS (Receipt #1163876) | TOM | TOM | | H01 | C | 4633840 |
MEMORIAL HOSPITAL | H02 | C | 04/19/2013 | 5YR 11-08--OTIS--PHONE IN CAR NOT WORKING | TOM | TOM | | H02 | C | 4515064 |
MEMORIAL HOSPITAL | H01 | C | 10/30/2012 | 5YR 11-08--OTIS (Receipt #1090886) | TOM | TOM | | H01 | C | 4412531 |
MEMORIAL HOSPITAL | H02 | C | 04/18/2012 | 5 YR 11-08--OTIS | TOM | TOM | | H02 | C | 4303459 |
MEMORIAL HOSPITAL | H01 | C | 10/05/2011 | 5 YR 11-08--OTIS (Receipt #1009348) | TOM | TOM | | H01 | C | 4229064 |
MEMORIAL HOSPITAL | H02 | C | 04/08/2011 | 5YR 11-08--OTIS | TOM | TOM | | H02 | C | 4142490 |
MEMORIAL HOSPITAL | H01 | C | 10/01/2010 | 5YR-11-08--OTIS (Receipt #942670) | TOM | TOM | | H01 | C | 4064434 |
MEMORIAL HOSPITAL | H02 | C | 04/06/2010 | 5 YR 11-08--OTIS--PIT LIGHT | TOM | TOM | | H02 | C | 3968404 |
MEMORIAL HOSPITAL | H01 | C | 10/01/2009 | OTIS AND LOCKBOX 5 YR 11/08 (Receipt #878875) | ERIC | ERIC | | H01 | C | 3892819 |
MEMORIAL HOSPITAL | H02 | C | 04/30/2009 | 5 YR 11-08--OTIS | TOM | TOM | | H02 | C | 3829772 |
MEMORIAL HOSPITAL | HE16 | C | 11/21/2008 | WITNESSED 5 YEAR TRACTION SAFETY TEST | ERIC | ERIC | | HE16 | C | 3794390 |
MEMORIAL HOSPITAL | H01 | C | 10/30/2008 | 5YR EXPIRED--LAST TEST 7-03--OTIS (Receipt #833280) | TOM | TOM | | H01 | C | 3762899 |
MEMORIAL HOSPITAL | H02 | C | 04/04/2008 | 5 YR 7-03 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H02 | C | 2591201 |
MEMORIAL HOSPITAL | H01 | C | 10/08/2007 | 5 YR 7-03 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H01 | C | 2591198 |
MEMORIAL HOSPITAL | H02 | C | 04/13/2007 | 5 YR 7-03 --- OTIS ELEV. AND LOCKBOX | LES | LES | | H02 | C | 2591193 |
MEMORIAL HOSPITAL | H01 | C | 10/05/2006 | 5 YR 7-03 --- OTIS | LES | LES | | H01 | C | 2591192 |
MEMORIAL HOSPITAL | H02 | C | 04/05/2006 | 5 YR 7-03 --- OTIS | LES | LES | | H02 | C | 2591187 |
MEMORIAL HOSPITAL | H01 | C | 10/28/2005 | 5 YR 7-03 --- OTIS --- LEVEL 4 SOUTH DOOR UNLOCKED | LES | LES | | H01 | C | 2591186 |
MEMORIAL HOSPITAL | H02 | C | 04/20/2005 | 5 YR 7-03 --- OTIS --- LEVEL 4 SOUTH DOOR UNLOCKED | LES | LES | | H02 | C | 2591181 |
MEMORIAL HOSPITAL | H01 | C | 10/26/2004 | 5 YR 7-03 --- WATER IN PIT --- SUMP PUMP NOT PLUGED IN | LES | LES | | H01 | C | 2591180 |
MEMORIAL HOSPITAL | H02 | C | 04/28/2004 | 5 YR 7-03 --- OTIS | LES | LES | | H02 | C | 2591175 |
MEMORIAL HOSPITAL | H01 | C | 10/13/2003 | INITIAL INSPECTION-PERMIT ISSUED | TOM | TOM | | H01 | C | 2591174 |