WALKCON, LTD. | B= | C | 11/16/2004 | ALL FINALS COMPLETE | RICH | RICH | | B= | C | 2716462 |
WALKCON, LTD. | B= | P | 11/05/2004 | PARTIAL FINAL, NEED E= AND H= | RICH | RICH | | B= | P | 2716455 |
WALKCON, LTD. | BSP | T | 10/22/2004 | PAID (REC#601950)ADDITIONAL PLAN REVIEW TIME: $50.000 From: RUSSELL Added additional; hood, changed out makeup air unit and exhaust fan | RUSSELL | RUSSELL | | BSP | T | 2716447 |
WALKCON, LTD. | BSP | T | 09/21/2004 | PAID (REC#601950)ADDITIONAL PLAN REVIEW TIME: $50.000 From: BOB revisedplumbing at ohoto leb and sheet M-3 | BOB | BOB | | BSP | T | 2716441 |
WALKCON, LTD. | BFR | P | 09/15/2004 | INTERIOR WALLS AT LOSS PROVENTION, NORTH/WEST ENTRY | RICH | RICH | | BFR | P | 2716436 |
WALKCON, LTD. | B= | P | 09/10/2004 | PHARMACY ONLY | RICH | RICH | | B= | P | 2716430 |
WALKCON, LTD. | BFR | P | 09/09/2004 | PARTITION WALL AT SOUTH SHOPPING KART AREA | RICH | RICH | | BFR | P | 2716423 |
WALKCON, LTD. | BSP | T | 09/09/2004 | PAID (REC#593657)ADDITIONAL PLAN REVIEW TIME: $50.000 From: RONW | RONW | RONW | | BSP | T | 2716415 |
WALKCON, LTD. | BFR | P | 09/01/2004 | INTERIOR WALLS AT PHARMACY OK | RICH | RICH | | BFR | P | 2716407 |
WALKCON, LTD. | BFR | P | 08/20/2004 | REAR RESTROOM WALLS, OK | RICH | RICH | | BFR | P | 2716398 |
WALKCON, LTD. | BSP | T | 08/11/2004 | PAID (REC#589564)ADDITIONAL PLAN REVIEW TIME: $100.000 From: RUSSELL Revisions to mechanical & plumbing | RUSSELL | RUSSELL | | BSP | T | 2716382 |
WALKCON, LTD. | BSP | T | 08/11/2004 | PAID (REC#589566)ADDITIONAL PLAN REVIEW TIME: $50.000 From: ROGER Revied Bathroom and cart room | ROGER | ROGER | | BSP | T | 2716390 |
CATAMOUNT CONSTRUCTORS, INC. | BSP | T | 06/17/2004 | PAID (REC#578710)ADDITIONAL PLAN REVIEW TIME: $50.000 From: TIMC Revised RTU locations and changed a few wall locations. | TIMC | TIMC | | BSP | T | 2716222 |
CATAMOUNT CONSTRUCTORS, INC. | BSP | T | 06/17/2004 | PAID (REC#578711)ADDITIONAL PLAN REVIEW TIME: $100.000 From: RUSSELL Revised plumbing and mechanical | RUSSELL | RUSSELL | | BSP | T | 2716229 |
CATAMOUNT CONSTRUCTORS, INC. | BSP | T | 06/16/2004 | PAID (REC#578712)ADDITIONAL PLAN REVIEW TIME: $100.000 From: RUSSELL Revised mechanical and plumbing | RUSSELL | RUSSELL | | BSP | T | 2716215 |
CATAMOUNT CONSTRUCTORS, INC. | BSP | T | 05/06/2004 | PAID (REC#578713)ADDITIONAL PLAN REVIEW TIME: $50.000 From: TIMC Revised arch sheets. | TIMC | TIMC | | BSP | T | 2716191 |
CATAMOUNT CONSTRUCTORS, INC. | BSP | T | 05/06/2004 | PAID (REC#578714)ADDITIONAL PLAN REVIEW TIME: $50.000 From: TERRY | TERRY | TERRY | | BSP | T | 2716199 |
CATAMOUNT CONSTRUCTORS, INC. | BSP | T | 05/06/2004 | PAID (REC#578715)ADDITIONAL PLAN REVIEW TIME: $100.000 From: RUSSELL Revised plumbing and mechanical | RUSSELL | RUSSELL | | BSP | T | 2716207 |
STRATEGY CONSTRUCTION CO., INC | E= | C | 11/05/2004 | | JERRY | JERRY | | E= | C | 2716318 |
STRATEGY CONSTRUCTION CO., INC | E= | R | 11/01/2004 | NOTHING CHANGED FROM LAST INSPECTION | JERRY | JERRY | | E= | R | 2716310 |
STRATEGY CONSTRUCTION CO., INC | E= | P | 10/28/2004 | SEE PERMIT FOR FINAL | JERRY | JERRY | | E= | P | 2716303 |
STRATEGY CONSTRUCTION CO., INC | ER | P | 09/15/2004 | LOSS PREVENTION ROOM WALLS,PHARMACY IS FINALED | JERRY | JERRY | | ER | P | 2716295 |
STRATEGY CONSTRUCTION CO., INC | E= | P | 09/13/2004 | FOR FINAL ON PHARMACY----ID PANEL SCHEDULE--FOR ABOVE PHARMACY--LIGHT FOR TRANSFORMER,COVER FOR JUNCTION BOX,SUPPORT CABLE AND CONDUIT PER CODE,END CAPS FOR FIXTURES THAT REMAIN AFTER YOU REMOVED THE ONES THAT WERE IN THE NEW PHARMACY AREA,INSTALL CORRECT LUG FOR THE TRANSFORMER NETURAL CONNECTION | JERRY | JERRY | | E= | P | 2716287 |
STRATEGY CONSTRUCTION CO., INC | E= | P | 09/10/2004 | PHARMACY GRID CEILING----CHECK WATER HEATER DISCONNECT,JUNCTION BOXES AND TRANSFORMER ABOVE WIRE IN PHARMACY CEILING | JERRY | JERRY | | E= | P | 2716277 |
STRATEGY CONSTRUCTION CO., INC | ER | P | 09/07/2004 | WALLS IN FRONT BATHS | JERRY | JERRY | | ER | P | 2716269 |
STRATEGY CONSTRUCTION CO., INC | ER | P | 09/01/2004 | PHARMACY WALLS | JERRY | JERRY | | ER | P | 2716260 |
STRATEGY CONSTRUCTION CO., INC | ESL | P | 08/25/2004 | INTERIOR SLAB BY MILK COOLERS | JERRY | JERRY | | ESL | P | 2716252 |
STRATEGY CONSTRUCTION CO., INC | ER | P | 08/20/2004 | BATH WALLS | JERRY | JERRY | | ER | P | 2716245 |
STRATEGY CONSTRUCTION CO., INC | ER | R | 08/19/2004 | COMPLY WITH 348,GROUND TAILS FOR BOXES,NO PERMIT FOUND | JERRY | JERRY | | ER | R | 2716237 |
SOURCE REFRIGERATION & HVAC | H= | C | 11/05/2004 | BALANCE REPORT RECEIVED ON 11/8 LS. | LYNNS | LYNNS | | H= | C | 2716373 |
SOURCE REFRIGERATION & HVAC | H= | P | 11/04/2004 | STILL NEED BALANCE REPORT ON TYPE I HOOD AND MUA. | LYNNS | LYNNS | | H= | P | 2716365 |
RIAL HEATING AND AIR CONDITIONING, INC. | H= | C | 11/03/2004 | HRP FINAL. | LYNNS | LYNNS | | H= | C | 2716184 |
HEATING & PLUMBING ENGINEERS, INC | HI | C | 11/01/2004 | 10# TEST AND DESIGN OK ON LINE RADIANT HEATER. | LYNNS | LYNNS | | HI | C | 2716153 |
SOURCE REFRIGERATION & HVAC | HD | C | 11/01/2004 | GREASE DUCT WRAP COMPLETE. | LYNNS | LYNNS | | HD | C | 2716357 |
HEATING & PLUMBING ENGINEERS, INC | H= | C | 11/01/2004 | GAS FINAL. | LYNNS | LYNNS | | H= | C | 2716142 |
SOURCE REFRIGERATION & HVAC | HV | C | 11/01/2004 | VENT OFF RADIANT HEATER COMPLETE. | LYNNS | LYNNS | | HV | C | 2716349 |
SOURCE REFRIGERATION & HVAC | HD | P | 10/27/2004 | GREASE DUCT OK TO FIRE WRAP. | LYNNS | LYNNS | | HD | P | 2716341 |
SOURCE REFRIGERATION & HVAC | H= | P | 09/10/2004 | HVAC FINAL IN PHARMACY ONLY. | LYNNS | LYNNS | | H= | P | 2716333 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRP | P | 09/09/2004 | 2- 250# TESTS ON LINES TO DAIRY CASE OK. WILL CALL FOR NEXT TWO CASES WHEN READY. | LYNNS | LYNNS | | HRP | P | 2716169 |
RIAL HEATING AND AIR CONDITIONING, INC. | HRP | R | 09/07/2004 | COULD NOT FIND CONTRACTOR OR STORE REP. TO SHOW ME THE TESTS. NEXT TIME NEED CONTACT PHONE NUMBER AND ESCORT TO DO INSPECTION. | LYNNS | LYNNS | | HRP | R | 2716160 |
SOURCE REFRIGERATION & HVAC | HD | P | 09/03/2004 | ROUGH DUCT IN PHARMACY AREA OK TO INSULATE. NEED TO SEE REGISTER DROPS AND CONNECTIONS YET. | LYNNS | LYNNS | | HD | P | 2716325 |
WALKCON, LTD. | P= | C | 11/03/2004 | | LEE | LEE | | P= | C | 2716623 |
WALKCON, LTD. | PB | C | 09/16/2004 | FLOOR DRAINS AT FISH TANKS AND BEER COOLER OK | LEE | LEE | | PB | C | 2716615 |
WALKCON, LTD. | PB | P | 09/14/2004 | TWO GROCERY FREEZER DRAINS OK | LEE | LEE | | PB | P | 2716607 |
WALKCON, LTD. | PB | P | 09/13/2004 | GROCERY FREEZER DRAINS -- EAST FLOOR DRAIN OK, OTHER DRAIN WILL NEED VENT TAKE OFF ROLLED TO MISS FREEZER LEGS AND RETEST, HORIZ. VENT NEEDS TO BE A MIN. 6" ABOVE FLOOR | LEE | LEE | | PB | P | 2716599 |
WALKCON, LTD. | P= | P | 09/10/2004 | PHOTO LAB -- STILL NEED SILVER RECOVERY UNIT, PHARMACY -- MIN. 6" C/L ON W/C FLUSH VALVE REQUIRED, EXPOSE C/O AT SINK, WATER TEMP EXCEEDS 110 DEGREES AT LAV, EXTRA SLIP JOINT ON OUTLET SIDE OF P-TRAP AT SINGLE BOWL SINK | LEE | LEE | | P= | P | 2716591 |
WALKCON, LTD. | P= | P | 09/09/2004 | PHOTO LAB FINAL --- NEED MIN 1-1/4" PAN DRAIN, CUT T&P DRAIN 1" ABOVE RIM OF W/H PAN, SILVER RECOVERY UNIT NOT INSTALLED, SUPPORT HORIZ. PVC AND TRAP ARM, NO HOT WATER, WHAT IS DUAL CHECK B.P. FOR ? | LEE | LEE | | P= | P | 2716583 |
WALKCON, LTD. | PB | P | 09/07/2004 | REVENT RELOCATED FLOOR DRAINS AT COOLERS X 2 AS PER PLANS | JEFF | JEFF | | PB | P | 2716566 |
WALKCON, LTD. | PTO | P | 09/07/2004 | 3 LAVS PER RESTROOM OK, PLANS BEING REVISED. SEE RUSS IF NEED MORE INFO. | KYE | KYE | | PTO | P | 2716557 |
WALKCON, LTD. | PTO | P | 09/07/2004 | FRONT BATH ROOMS WALLS OK PENDING APPROVAL OF REMOVING TWO LAVS | JEFF | JEFF | | PTO | P | 2716575 |
WALKCON, LTD. | PB | P | 09/03/2004 | PHOTO LAB OK | JACK | JACK | | PB | P | 2716549 |
WALKCON, LTD. | PB | P | 09/02/2004 | PHARMACY OK | LEE | LEE | | PB | P | 2716535 |
WALKCON, LTD. | P= | P | 09/02/2004 | MENS RESTROOM, NOTE: ALL FIXTURES WERE REMOVED FROM WALLS AND FLOORS FOR REMODEL AND WATER PIPE ADJUSTED FOR SENSOR INSTALLATION, NO CHANGES TO W/C STALLS, SIDE CLEARANCE ISSUES EXISTING, CRITICAL LEVEL AT URNAL LESS THAN 6", H/C URNAL GREATER THAN 17" A.F.F. (21-1/2"), WOMENS RESTROOM OK | LEE | LEE | | P= | P | 2716525 |
WALKCON, LTD. | PTO | P | 09/02/2004 | PHARMACY OK PENDING 3/4" W/H PAN DRAIN CHANGED TO MIN. 1-1/4" AND VTR, CHECK BOTH AT FINAL (DONT FORGET TO WRAP PVC STACKS THRU FLOOR) | LEE | LEE | | PTO | P | 2716541 |
WALKCON, LTD. | PTO | R | 09/01/2004 | PHARMACY NOT READY | LEE | LEE | | PTO | R | 2716517 |
WALKCON, LTD. | PB | P | 09/01/2004 | STILL HAVE VENTING ISSUES IN PHARMACY | LEE | LEE | | PB | P | 2716510 |
WALKCON, LTD. | PB | R | 08/30/2004 | PHARMACY, USE LONG TURN FITTINGS UNDERSLAB, FLOOR DRAINS NOT VENTED PROPERLY (HILL VENTING NOT ALLOWED) | LEE | LEE | | PB | R | 2716503 |
WALKCON, LTD. | PB | P | 08/25/2004 | F/D FOR GROCERY BUNKER NEAR MILK CASE OK, ACCESSABLE C/O REQUIRED ON VENT AT FINAL | LEE | LEE | | PB | P | 2716485 |
WALKCON, LTD. | PTO | P | 08/25/2004 | REAR RESTROOMS OK | LEE | LEE | | PTO | P | 2716493 |
WALKCON, LTD. | PTO | P | 08/19/2004 | WALLS IN REAR RESTROOMS, STILL NEED ABOVE CEILING VENT TIE IN, H20 SAME AREA COMPLETE | LEE | LEE | | PTO | P | 2716477 |
WALKCON, LTD. | PB | P | 08/19/2004 | REAR RESTROOMS OK | LEE | LEE | | PB | P | 2716470 |