BRYAN CONSTRUCTION, INC. | B= | C | 08/19/2004 | COMPLETE | RICH | RICH | | B= | C | 2740934 |
BRYAN CONSTRUCTION, INC. | BSP | P | 08/05/2004 | FIRE CHAULKING AT CORRIDOR OK | RICH | RICH | | BSP | P | 2740926 |
BRYAN CONSTRUCTION, INC. | BSP | T | 08/02/2004 | PAID (REC#586777)ADDITIONAL PLAN CHECK FEE $50. RUSSELL | JAN | JAN | | BSP | T | 2740918 |
BRYAN CONSTRUCTION, INC. | BFR | P | 07/01/2004 | EAST SIDE OFFICE WALLS, RECALL CORRIDOR PENETRATIONS | RICH | RICH | | BFR | P | 2740910 |
BRYAN CONSTRUCTION, INC. | BFR | P | 06/23/2004 | OFFICE WALLS, SEE PLANS, OTHER ROUGHS | RICH | RICH | | BFR | P | 2740903 |
RYBA ELECTRIC, INC. | E= | C | 08/18/2004 | | JERRY | JERRY | | E= | C | 2741144 |
RYBA ELECTRIC, INC. | E= | P | 08/17/2004 | FOR FINAL-----GFCI'S BEHIND VENDING MACHINES | JERRY | JERRY | | E= | P | 2741135 |
RYBA ELECTRIC, INC. | E= | P | 08/13/2004 | NORTH END EXTERIOR OFFICES | JERRY | JERRY | | E= | P | 2741128 |
RYBA ELECTRIC, INC. | ER | P | 08/03/2004 | GRID CEILING COMPLETE--------EXCEPT 2 LARGE JUNCTION BOXES ONE IN HALL AND I IN RECEPTION AREA | JERRY | JERRY | | ER | P | 2741120 |
RYBA ELECTRIC, INC. | ER | P | 07/29/2004 | GRID CEILING--KITCHEN,COFFEE,COPY AND LARGE EAST EXTERIOR ROOMS | JERRY | JERRY | | ER | P | 2741113 |
RYBA ELECTRIC, INC. | ER | P | 07/22/2004 | HARD LIDS BY INTERIOR RECEPTION AND BY ELEVATOR,GRID CEILING LARGE AREA | JERRY | JERRY | | ER | P | 2741105 |
RYBA ELECTRIC, INC. | ER | P | 07/16/2004 | HARD LID RECEPTION AREA,GRID CEILING EXTERIOR OFFICES | JERRY | JERRY | | ER | P | 2741097 |
RYBA ELECTRIC, INC. | ER | P | 07/13/2004 | HARD LID LARGE ROOM BT ELEVATOR | JERRY | JERRY | | ER | P | 2741089 |
RYBA ELECTRIC, INC. | ER | P | 07/07/2004 | WALLS | JERRY | JERRY | | ER | P | 2741081 |
RYBA ELECTRIC, INC. | ER | P | 06/24/2004 | WALLS | JERRY | JERRY | | ER | P | 2741074 |
RYBA ELECTRIC, INC. | ER | P | 06/17/2004 | EXTERIOR OFFICES | JERRY | JERRY | | ER | P | 2741067 |
RYBA ELECTRIC, INC. | ER | R | 06/16/2004 | STRAP CABLE,HIDDEN BOXES IN WINDOW POSTS | JERRY | JERRY | | ER | R | 2741060 |
HEATING & PLUMBING ENGINEERS, INC | H= | C | 08/13/2004 | GAS FINAL. | LYNNS | LYNNS | | H= | C | 2740950 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 08/13/2004 | FIREPLACE FINAL. | LYNNS | LYNNS | | H= | C | 2741044 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 08/13/2004 | HVAC FINAL COMPLETE. PARTIAL FINAL PENDING PERMIT FOR FIREPLACES. | LYNNS | LYNNS | | H= | P | 2741052 |
PEAK HEATING & AIR CONDITIONING, INC. | HV | C | 07/26/2004 | 2- FIREPLACE VENTS COMPLETE. OK TO COVER. | LYNNS | LYNNS | | HV | C | 2741037 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 07/20/2004 | ROUGH DUCT COMPLETE IN NORTH PORTION OF JOB. NEED TO SEE SOUTH HALF YET. | LYNNS | LYNNS | | HD | P | 2741029 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 07/13/2004 | ROUGH DUCT COMPLETE EXCEPT FOR FAN AND DUCT IN NORTH OFFICE AREA. | LYNNS | LYNNS | | HD | P | 2741021 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 07/13/2004 | AREA OF ROOMS 512 THROUGH 535, OK TO DROP TILE. NEED TO SEE FAN AND DUCT FOR RETURN FROM NORTH OFFICES YET. | LYNNS | LYNNS | | H= | P | 2741005 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 07/13/2004 | OK TO DROP TILE IN ROOMS 512- 535. | LYNNS | LYNNS | | H= | P | 2741013 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 07/07/2004 | FIRE DAMPER FRAMING X2 OK. | LYNNS | LYNNS | | HD | P | 2740997 |
HEATING & PLUMBING ENGINEERS, INC | HI | C | 07/06/2004 | 10# TEST ON 1 1/4" X 3/4 X 3/4 LINE, 14' LONG. NEED BTU'S ON FIREPLACES. VERIFIED 20K F/P'S ON 7/7 LS. | LYNNS | LYNNS | | HI | C | 2740942 |
HEATING & PLUMBING ENGINEERS, INC | P= | C | 08/18/2004 | | LEE | LEE | | P= | C | 2740989 |
HEATING & PLUMBING ENGINEERS, INC | P= | R | 08/17/2004 | NOT READY, NO HOT WATER | LEE | LEE | | P= | R | 2740981 |
HEATING & PLUMBING ENGINEERS, INC | PTO | C | 07/19/2004 | CHECK FOR AAV AT ISLAND SINK ON FINAL | LEE | LEE | | PTO | C | 2740973 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/13/2004 | NEED ALL UNDERFLOOR AND VENT TIE-INS UPPER LEVEL | LEE | LEE | | PTO | P | 2740966 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/02/2004 | TEST AND WALLS OK AT BREAK SINKS 509/539, NO VENT RAN YET AT 509, VERIFY VENT CONNECTION AT 539, NO ACCESS TO LOWER LEVEL, NO OTHER SINK ROUGHS COMPLETE AT THIS TIME, REVISE PLANS FOR THE RELOCATION OF SINK ROOM 502 | JEFF | JEFF | | PTO | P | 2740958 |