EXECUTIVE CUSTOM CONSTRUCTION, INC. | B= | C | 03/31/2005 | MAG HOLD OPEN DEVICES AT EXIT DOORS TESTED AND PASSED WITH ELEC POWER AND BATTERY BACK-UP DISCONNECTED | BLAKE | BLAKE | | B= | C | 2799732 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BIN | R | 03/30/2005 | NEEDS TO BE CALLED IN UNDER TENANT FINISH PERMIT | BLAKE | BLAKE | | BIN | R | 2799725 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | B= | R | 03/29/2005 | NEED H=/ NEED SCOLD GUARDS INSTALLED AT BOTH 1ST FLOOR RESTROOMS | BLAKE | BLAKE | | B= | R | 2799716 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BFR | P | 03/29/2005 | OK PENDING MECH ROUGH INSPECTION | BLAKE | BLAKE | | BFR | P | 2799709 |
EXECUTIVE CUSTOM HOMES | BFR | P | 02/24/2005 | SHELL FRAME OK PENDING OTHEER TRADES | BLAKE | BLAKE | | BFR | P | 2799567 |
EXECUTIVE CUSTOM HOMES | BFR | P | 02/16/2005 | POINT LOADS CARRIED DOWN FROM ABOVE | BLAKE | BLAKE | | BFR | P | 2799559 |
EXECUTIVE CUSTOM HOMES | BIN | P | 02/08/2005 | EAST ENTRY OK | BLAKE | BLAKE | | BIN | P | 2799550 |
EXECUTIVE CUSTOM HOMES | BIN | P | 02/04/2005 | NEED ENERGY CALC SHEET/ OK TO ROCK WALLS OVER R-19 | BLAKE | BLAKE | | BIN | P | 2799542 |
EXECUTIVE CUSTOM HOMES | BFR | P | 01/06/2005 | NEED TO REINSPECT TRUSS' AND WEST STAIRWELL/ ALSO NEED TO CARRY POINT LOADS DOWN FROM WEST STAIRWELL I-BEAM | BLAKE | BLAKE | | BFR | P | 2799534 |
EXECUTIVE CUSTOM HOMES | BFN | C | 08/12/2004 | REC'D ENG LETTER TO DELETE BUTTRESS WALLS | BLAKE | BLAKE | | BFN | C | 2799525 |
EXECUTIVE CUSTOM HOMES | BFT | C | 08/03/2004 | FOOTER AND PADS OK | BLAKE | BLAKE | | BFT | C | 2799518 |
MEYER ELECTRIC | E= | C | 03/29/2005 | | GARY | GARY | | E= | C | 2799511 |
MEYER ELECTRIC | ES | C | 01/26/2005 | COMMERCIAL SERVICE: 4-WIRE UNDERGROUND,3 PHASE,120/208,CT METER,TWO 400 AMP AND ONE 225 AMP MAINS,NEW OFFICE BUILDING,MEYER ELECTRIC | JERRY | JERRY | | ES | C | 2799504 |
MEYER ELECTRIC | ES | R | 01/25/2005 | BOND NETURAL,BOND CT METERBASE,LB'S INSTALLED UNDERGROUND,LUGS LOOSE ON GROUND BUSHING,WIRE LOOSE UNDER SUB PANEL LUGS,WHERE ARE GROUND RODS,COMPLETE REINSPECTION | JERRY | JERRY | | ES | R | 2799488 |
MEYER ELECTRIC | EUG | P | 08/26/2004 | SERVICE FEEDER CONDUITS.+ OUTSIDE CONDUITS UNDER SLAB | RON | RON | | EUG | P | 2799496 |
ROCKY MOUNTAIN SERVICE CO.LLC. | H= | C | 03/30/2005 | 14- 230# RE-TESTS ON REF. LINES OK. CORRECTION MADE ON LINE INSTALLATION. | LYNNS | LYNNS | | H= | C | 2799703 |
O.M.A.G.M., INC. | H= | C | 03/30/2005 | GAS FINAL. | LYNNS | LYNNS | | H= | C | 2799591 |
ROCKY MOUNTAIN SERVICE CO.LLC. | H= | P | 03/29/2005 | OUTSIDE SUPPORTS ON REF. LINES OK, ATTIC LINES NOT READY. | LYNNS | LYNNS | | H= | P | 2799694 |
ROCKY MOUNTAIN SERVICE CO.LLC. | H= | P | 03/28/2005 | STILL NEED TO SUPPORT REF. LINES IN ATTIC TO MANUFACTURER'S GUIDELINES. SUPPORT OUTSIDE LINES TO CONDENSERS 4'' OFF GROUND LEVEL. | LYNNS | LYNNS | | H= | P | 2799686 |
ROCKY MOUNTAIN SERVICE CO.LLC. | HRP | P | 03/24/2005 | 14- 230# TESTS ON LINE SETS TO FURNACES. NEED TO COMPLY WITH MANUFACTURER'S INSTALLATION AND DESIGN GUIDE LINES FOR CAPTURE OF OIL RETURN. | LYNNS | LYNNS | | HRP | P | 2799640 |
ROCKY MOUNTAIN SERVICE CO.LLC. | HRP | T | 03/18/2005 | PAID (REC#627347): STILL DO NOT HAVE PERMIT FOR WORK BEING DONE. | LYNNS | LYNNS | | HRP | T | 2799680 |
ROCKY MOUNTAIN SERVICE CO.LLC. | HD | R | 03/17/2005 | NEED A FIRE DAMPER IN ELEVATOR EXHAUST AT TOP OF SHAFT, HAVE AN OUTSIDE LOUVER INTO SHAFT AND NEEDS A FIRE DAMPER ALSO. | LYNNS | LYNNS | | HD | R | 2799671 |
ROCKY MOUNTAIN SERVICE CO.LLC. | HV | C | 02/28/2005 | 14- FURNACE AND 4 EXHAUST FAN VENTS OK. | LYNNS | LYNNS | | HV | C | 2799661 |
ROCKY MOUNTAIN SERVICE CO.LLC. | HC | C | 02/28/2005 | OK FOR METER. | LYNNS | LYNNS | | HC | C | 2799647 |
O.M.A.G.M., INC. | HI | C | 02/11/2005 | 60# TEST ON ELEVATED GAS AND DESIGN OK. | LYNNS | LYNNS | | HI | C | 2799583 |
ELITE PLUMBING & HEATING, INC. | P= | C | 03/08/2005 | | LEE | LEE | | P= | C | 2799632 |
ELITE PLUMBING & HEATING, INC. | P= | P | 02/03/2005 | NEED WATER METER | LEE | LEE | | P= | P | 2799623 |
ELITE PLUMBING & HEATING, INC. | PTO | C | 02/02/2005 | WILL NEED METER LOOP COMPLETE FOR FINAL | LEE | LEE | | PTO | C | 2799615 |
ELITE PLUMBING & HEATING, INC. | PB | C | 02/02/2005 | | LEE | LEE | | PB | C | 2799606 |
ELITE PLUMBING & HEATING, INC. | PB | R | 09/08/2004 | SCOPE OF WORK DOES NOT MATCH APPROVED PLANS, WATER SERVICE AND FLOOR DRAIN UNDERSIZED, ELEV. SUMP DRAIN COVERED UP | LEE | LEE | | PB | R | 2799598 |