COLORADO SPRINGS CONST. GROUP | B= | C | 02/09/2005 | TGC APPROVED HALF LOG BEAM @ TRELLIS AS INSTALLED
| MIKE | MIKE | | B= | C | 2908285 |
COLORADO SPRINGS CONST. GROUP | B= | P | 01/24/2005 | NEED PATIO COVER BEAM SIZE PER DESIGN | MIKE | MIKE | | B= | P | 2908275 |
COLORADO SPRINGS CONST. GROUP | BFR | C | 01/24/2005 | ALL FRAMING COVERED WITHOUT INSPECTION,APPROVED BY CURTIS M.
| MIKE | MIKE | | BFR | C | 2908268 |
COLORADO SPRINGS CONST. GROUP | BFR | R | 01/18/2005 | NEED SEPERATE PERMIT FOR DETACHED PATIO COVER(NOTIFIED CONTRACATOR @ PIER INSPECTION),ALL INTERIOR FRAMING COVERED WITHOUT INSPECTION
| MIKE | MIKE | | BFR | R | 2908259 |
COLORADO SPRINGS CONST. GROUP | BFT | C | 12/14/2004 | DIG PIERS TO SIZE & DEPTH SPECIFIED ON APPROVED PLANS | MIKE | MIKE | | BFT | C | 2908252 |
SEC, SNELLSTROM ELECTRICAL CONTRACTING | E= | C | 01/06/2005 | | GARYL | GARYL | | E= | C | 2908245 |
SEC, SNELLSTROM ELECTRICAL CONTRACTING | E= | R | 01/05/2005 | NOT READY, TRIED TO USE RECEPT'S HAD TO GO TO GFI BRKERS
| GARYL | GARYL | | E= | R | 2908237 |
SEC, SNELLSTROM ELECTRICAL CONTRACTING | E= | R | 01/03/2005 | SEE NOTES | GARYL | GARYL | | E= | R | 2908229 |
SEC, SNELLSTROM ELECTRICAL CONTRACTING | ER | R | 01/03/2005 | NEED GFI PROTECTION ON ALL KITCHEN RECEPTACLES | GARYL | GARYL | | ER | R | 2908221 |
SCHNEIDER PLUMBING & HEATING | P= | C | 01/20/2005 | | JACK | JACK | | P= | C | 2908213 |
SCHNEIDER PLUMBING & HEATING | P= | P | 01/14/2005 | WATERHEATER TO CLOSE TO WALL, REST OK | JACK | JACK | | P= | P | 2908206 |
SCHNEIDER PLUMBING & HEATING | P= | R | 01/11/2005 | WATER TEMP EXCEEDS 110 AT LAVS, LACKS BACKFLOW PREVENTOR AT SODA EQUIP. WATER SUPPLY, INSTALL STRAINERS IN FLOOR SINKS, MAINTAIN AIR GAP ON INDIRECT DRAINS, HOOK UP ICE MAKER H20 AND DRAIN, 3- COMP SINK DRAIN FLAT AND COULD USE SUPPORT, W/H C/O ACCESS PANEL LACKS ACCESS, W/H REQUIRES 3" SIDE AND REAR CLEARANCE TO COMBUSTABLES, EXPANSION DEVICE REQUIRED IF B.P DOWN STREAM (DID YOU CHECK?) | LEE | LEE | | P= | R | 2908199 |
SCHNEIDER PLUMBING & HEATING | PTO | P | 12/23/2004 | NEEED TO REVISE PRINT TO WORK BEING DONE | JACK | JACK | | PTO | P | 2908191 |
SCHNEIDER PLUMBING & HEATING | PB | P | 12/23/2004 | NEED INSTRUCTIONS FOR GREASE TRAP REDUCED OUTLET, PROCEED AT OWN RISK | JACK | JACK | | PB | P | 2908183 |