BEAZER HOMES HOLDING CORP. | B= | C | 11/09/2005 | UNFINISHED BSMNT | SEANA | SEANA | | B= | C | 3058375 |
BEAZER HOMES HOLDING CORP. | BSP | P | 09/30/2005 | GARAGE HAT CHANNEL OK | SEANA | SEANA | | BSP | P | 3058368 |
BEAZER HOMES HOLDING CORP. | BFR | C | 09/28/2005 | ENGINEERING ON FILE FOR TRUSS LEDGER, NEED CLEAR COPY OF TRUSS FIX FOR FILE(TRUSS FIX OK) | SEANA | SEANA | | BFR | C | 3058359 |
BEAZER HOMES HOLDING CORP. | BIN | C | 09/28/2005 | | SEANA | SEANA | | BIN | C | 3058350 |
BEAZER HOMES HOLDING CORP. | BFR | R | 09/21/2005 | FUR DOWN AT HEAT RUNS GARAGE FOR R 19-BACKBLOCKS OHD BRACKETS-16" OC AT GARAGE LID-FIRESTOPS-COMBUSTIBLES CHASE-NEED TRUSS FIX FOR T23 AND BRACE PER ENG-NEED ENG FOR LEDGER AT RAFTERS LIVING-1/2 BOLTS AT 4 PLY M/L BEAM-CLIP RAFTERS AT FIREPLACE | GREGC | GREGC | | BFR | R | 3058342 |
BEAZER HOMES HOLDING CORP. | BSP | P | 09/08/2005 | FRONT PORCH FRAME/POST OK | SEANA | SEANA | | BSP | P | 3058334 |
BEAZER HOMES HOLDING CORP. | BSP | P | 08/23/2005 | SHEAR OK | SEANA | SEANA | | BSP | P | 3058326 |
BEAZER HOMES HOLDING CORP. | BFI | C | 07/20/2005 | RIGID INSULATION APPLIED TO EXTERIOR OF FOUNDATION, WILL NEED 3' @ INTERIOR BY FINAL | SEANA | SEANA | | BFI | C | 3058319 |
BEAZER HOMES HOLDING CORP. | BFD | C | 07/15/2005 | | SEANA | SEANA | | BFD | C | 3058312 |
BEAZER HOMES HOLDING CORP. | BFD | R | 07/12/2005 | EXCESSIVE TRASH/CONCRETE, SOILS ON FILE | SEANA | SEANA | | BFD | R | 3058303 |
BEAZER HOMES HOLDING CORP. | BFN | C | 06/20/2005 | DESIGN ON FILE / NEED SOILS | JIMA | JIMA | | BFN | C | 3058296 |
BEAZER HOMES HOLDING CORP. | BFT | C | 06/10/2005 | DESIGN/OPEN HOLE=1,000PSF, 2 INTERIOR PADS OK | SEANA | SEANA | | BFT | C | 3058290 |
D & J QUALITY ELECTRIC INC | E= | C | 10/28/2005 | | RON | RON | | E= | C | 3058248 |
D & J QUALITY ELECTRIC INC | E= | R | 10/26/2005 | BOND GAS PIPE. | RON | RON | | E= | R | 3058242 |
D & J QUALITY ELECTRIC INC | ES | C | 09/28/2005 | RESIDENTIAL UNDERGROUND: 2OOA 3 WIRE NEW RES.SERVICE BY D&J ELECTRIC | THOMAS | THOMAS | | ES | C | 3058234 |
D & J QUALITY ELECTRIC INC | EUG | C | 09/22/2005 | | THOMAS | THOMAS | | EUG | C | 3058226 |
D & J QUALITY ELECTRIC INC | ER | C | 09/20/2005 | | THOMAS | THOMAS | | ER | C | 3058216 |
D & J QUALITY ELECTRIC INC | ER | R | 09/19/2005 | DAMAGED ROMEX IN WALL BETWEEN GARAGE AND LIVING ROOM---STAPLE ROMEX AT CIELING BOX IN BASEMENT | THOMAS | THOMAS | | ER | R | 3058209 |
FRIEND GROUP, INC. | H= | C | 11/03/2005 | | TED | TED | | H= | C | 3058422 |
FRIEND GROUP, INC. | H= | P | 10/28/2005 | SEAL W/H VENTING AT TOP OF W/H, NO PERMIT CARD FOUND | TED | TED | | H= | P | 3058414 |
FRIEND GROUP, INC. | HC | C | 09/15/2005 | OK FOR METER | TED | TED | | HC | C | 3058408 |
FRIEND GROUP, INC. | HRR | C | 09/15/2005 | | TED | TED | | HRR | C | 3058399 |
FRIEND GROUP, INC. | HRR | R | 09/14/2005 | FURNACE VENTING APART STILL | TED | TED | | HRR | R | 3058391 |
FRIEND GROUP, INC. | HRR | R | 09/13/2005 | FURNACE VENT APART, NEED EXHAUST FAN POWDER BATH | TED | TED | | HRR | R | 3058383 |
CHIEF HEATING AND GAS CORP. | HI | C | 09/13/2005 | 1'' FURNACE, W/H, FIREPLACE | TED | TED | | HI | C | 3058281 |
B & L PLUMBING, INC. | P= | C | 11/08/2005 | | TED | TED | | P= | C | 3058275 |
B & L PLUMBING, INC. | P= | R | 11/04/2005 | NO COLD WATER TO KITCH SINK, MASTER SHOWER TOO HOT, WATER LEAK IN LAV CABINET HALLWAY BATH ROOM, CAP LAV OUTLET IN BASEMENT, SPRINKLER BACKFLOW INSTALLED | TED | TED | | P= | R | 3058268 |
B & L PLUMBING, INC. | PTO | C | 09/09/2005 | UNFINISHED BASEMENT | TED | TED | | PTO | C | 3058261 |
B & L PLUMBING, INC. | PB | C | 06/24/2005 | 4'' | JACK | JACK | | PB | C | 3058254 |