HOMEOWNER | B= | C | 07/20/2007 | UPPER SLIDING GLASS DOOR IS BARRICADED | JEREMY | JEREMY | | B= | C | 3075504 |
HOMEOWNER | B= | R | 05/15/2007 | 17)NEED LADDER FOR ATTIC INSULATION INSPECTION 18)NEED APPROVED PLANS SHOWING RBD APPROVAL OF WIRE CABLE BALASTER SYSTEM @ REAR DECK 19)BALASTER SYSTEM @ REAR DECK CAN BE SEPERATED TO BE >4" AND IF APPROVED NEED ENGINEERING LETTER VERIFIYING THAT THE IMPACT RATING HAS BEEN MET 20)NEED TO SEE DECK FRAMING ON PLANS FOR DECK SUPPORTED ON ROOF OF GARAGE THIS NEEDS INSPECTION | BERTW | BERTW | | B= | R | 3075496 |
HOMEOWNER | B= | R | 05/15/2007 | 10)EXTEND SUMP DISCHARGE 5' FROM HOUSE 11)STEEL BEAM IN GARAGE NEEDS TO BE FIRE PROTECTED 12)NEED INSULATION CERTIFICATE POSTED 13)EXTEND MAIN STAIRCASE HANDRAIL TO #1 RISER AND TO #14 RISER 14)HEADROOM @ MAIN STIRCASE NEEDS TO BE 6' 6" MINIMUM 15)MAIN HALL BATH FAN NOT WORKING 16)WOOD BURNING STOVE FLU IS NOT PROPERLY ATTACHED AND PLEASE PROVIDE SPECIFICATIONS FOR REINSPECTION ____CONTINUED ON NEXT PAGE____ | BERTW | BERTW | | B= | R | 3075487 |
HOMEOWNER | B= | R | 05/15/2007 | 1)NEED GUARDRAILINGS @ ALL DECKS WHERE THERE IS A 30" VERTICLE DROP IN GRADE ELEVATION 5' HORIZONTALLY FROM WALKING SURFACE 2)NEED LANDING PAD 3' FROM #1 RISER @ FRONT DECK STAIRS 3)RISER HEIGHT VARIES >3/8" FRONT DECK STAIRS 4)NEED LANDING PAD 3' FROM RISER #1 @ WEST FACING EXTERIOR STAIRS 5)RISER HEIGHT >8" @ WEST FACING EXTERIOR STAIRS 6)SEAL ALL CANTIVER LIDS 7)SEAL ALL EXTERIOR PENETRATIONS 8)SEAL EXPOSED OSB @ REAR DOOR THRESHOLD ___HISTORY CONTINUED ON NEXT PAGE___ | BERTW | BERTW | | B= | R | 3075479 |
HOMEOWNER | BE | C | 04/24/2007 | Re-Activated for 1/2 of Permit Fee on 24-apr-2007 | SHELLEY | SHELLEY | | BE | C | 3075472 |
HOMEOWNER | BIN | C | 08/28/2006 | | TERRYB | TERRYB | | BIN | C | 3075464 |
HOMEOWNER | BSP | T | 08/25/2006 | PAID (REC#712729)ADDITIONAL PLAN REVIEW TIME: $50.000 From: DALEH spliced in new res check and calcs | DALEH | DALEH | | BSP | T | 3075455 |
HOMEOWNER | BIN | R | 08/24/2006 | 1)STAMPED ECC CALLS FOR R-22 @ EXTERIOR WALLS 2)NEED R-38 @ FLOOR SPACES OVER UNCONDITIOND AREAS 3) NEED R 13.5 BASEMENT WALLS 4) SOME WINDOWS EXCEED THE APPROVED U FACTOR OF .40 _______PLEASE________RECALL ENTIRE INSULATION INSPECTION WHEN READY___________ | BERTW | BERTW | | BIN | R | 3075448 |
HOMEOWNER | BFR | C | 07/18/2006 | | TERRYB | TERRYB | | BFR | C | 3075442 |
HOMEOWNER | BLA | C | 02/16/2006 | VEGAS ARE SURFACE MOUNTE DO NOT PENETRATE THE STRUCTURE | TERRYB | TERRYB | | BLA | C | 3075434 |
HOMEOWNER | BLA | R | 02/07/2006 | VEGAS NEED TO BE FLASHED | TERRYB | TERRYB | | BLA | R | 3075426 |
HOMEOWNER | BIN | P | 01/09/2006 | EXT. CANT.S OK | MICHAELA | MICHAELA | | BIN | P | 3075417 |
HOMEOWNER | BTR | C | 01/09/2006 | EDPM OK | MICHAELA | MICHAELA | | BTR | C | 3075410 |
HOMEOWNER | BTR | P | 12/29/2005 | FLAT ROOF, NEED TO RUN RUBBER UP PARATET TRANSITION AT END WALLS | TERRYB | TERRYB | | BTR | P | 3075403 |
HOMEOWNER | BFI | C | 10/05/2005 | | TERRYB | TERRYB | | BFI | C | 3075395 |
HOMEOWNER | BFD | C | 10/05/2005 | | TERRYB | TERRYB | | BFD | C | 3075387 |
HOMEOWNER | BBB | C | 07/29/2005 | | TERRYB | TERRYB | | BBB | C | 3075378 |
HOMEOWNER | BFT | C | 07/19/2005 | BALNCE OF FOOTER | TERRYB | TERRYB | | BFT | C | 3075370 |
HOMEOWNER | BFT | P | 06/22/2005 | ALL BUT INTERIOR FOOTINGS AND PADS AND UNDER GARAGE DOORS | TERRYB | TERRYB | | BFT | P | 3075363 |
HOMEOWNER | E= | C | 05/14/2007 | | MIKEC | MIKEC | | E= | C | 3075559 |
HOMEOWNER | E= | T | 05/04/2007 | PAID (REC#750725)SEE PREVIOUS REJECTION REGARDING GFCI PROTECTION FOR OUTLETS IN LAUNDRY ROOM WITHIN 6 FEET OF SINK [NOT DONE]---GFCI INSTALLED [SEE LAST INSPECTION] IN MUD ROOM, DOES NOT WORK----TIGHTEN IN USE COVER UPPER SOUTH ENTRY---ARC FAULT PROTECT ALL MASTER BEDROOM OUTLETS [SEE PREVIOUS REJECTION] | THOMAS | THOMAS | | E= | T | 3075552 |
HOMEOWNER | E= | R | 05/01/2007 | GFCI PROTECT ALL GARAGE OUTLETS; OUTLET IN MUD ROOM OUTLET IN LAUNDRY----GARAGE EXTERIOR OUTLET WON'T SET----INSTALL PANEL SCHEDULE----ARC FAULT PROTECT SMOKES---BASEMENT OUTLETS MUST BE GFCI PROTECTED & NOT ON BATH CIRCUIT---HORIZONTAL BLOCKING IN BASEMENT---MARK HOT WHITE WIRES IN PANEL BLACK---ENCLOSE CLOSET LIGHT BY GAR.---MASTER ARC WON'T SET---OUTLETS IN OFFICE & SOME IN GAR. ARE DEAD---GFCI PROTECT ISLAND OUTLETS | THOMAS | THOMAS | | E= | R | 3075544 |
HOMEOWNER | ER | C | 05/19/2006 | | MIKEC | MIKEC | | ER | C | 3075536 |
HOMEOWNER | ES | C | 05/18/2006 | RESIDENTIAL UNDERGROUND: TEMP. METER TO BE USED FOR PERMANENT POWER NO ACTION NEEDED HOMEOWNER | MIKEC | MIKEC | | ES | C | 3075528 |
HOMEOWNER | ER | R | 05/18/2006 | SEE OWNERS LIST | MIKEC | MIKEC | | ER | R | 3075520 |
HOMEOWNER | EUG | C | 12/05/2005 | | RED | RED | | EUG | C | 3075511 |
HOMEOWNER | H= | C | 04/24/2007 | OK | TCRIPPEN | TCRIPPEN | | H= | C | 3075636 |
HOMEOWNER | HWP | C | 08/04/2006 | | MARTY | MARTY | | HWP | C | 3075629 |
HOMEOWNER | HRR | C | 07/17/2006 | OK | DAVIDH | DAVIDH | | HRR | C | 3075621 |
HOMEOWNER | HRR | P | 06/19/2006 | BOILER INSTALL BOOK READS 8 INCHES APART MIN , AND 36 INCHES MAX , FOR VENTS , AIR HANDER AND DUCTS NOT INSTALLED , LINE SET INSULATION HAS BEEN CUT ALL THROUGH OUT AND NOT RESEALED NO DRAIN FOR AIR HANDLER USING 4 INCH OUTSIDE AIR FOR MUA TO DRYER ROOM GAS LINES NOT CAPPED OFF | TCRIPPEN | TCRIPPEN | | HRR | P | 3075614 |
HOMEOWNER | HRR | P | 06/16/2006 | CHANGE BOILER EXHAUST PIPING TO SOLID CORE PIPING, INSTALL AC DUCT WORK, ALL ELSE OK. | JIMV | JIMV | | HRR | P | 3075607 |
HOMEOWNER | HI | C | 04/17/2006 | | DAVIDH | DAVIDH | | HI | C | 3075598 |
HOMEOWNER | HC | C | 04/17/2006 | OK TO SET METER | DAVIDH | DAVIDH | | HC | C | 3075590 |
HOMEOWNER | HO | C | 04/17/2006 | 60 # TEST OK | DAVIDH | DAVIDH | | HO | C | 3075583 |
HOMEOWNER | HI | P | 04/06/2006 | NEED HIGHER TEST DESIGN IS OK 1-BOILER -COOK TOP , BBQ 3/4 INCH TRUNK LINE | TCRIPPEN | TCRIPPEN | | HI | P | 3075574 |
HOMEOWNER | HWP | P | 08/23/2005 | UNDER SLAB OK | JEFF | JEFF | | HWP | P | 3075568 |
HOMEOWNER | P= | C | 04/24/2007 | RECIEVED BACTERIOLOGICAL TEST. | MARTY | MARTY | | P= | C | 3075669 |
HOMEOWNER | PTO | C | 04/17/2006 | | MARTY | MARTY | | PTO | C | 3075662 |
HOMEOWNER | PTO | P | 04/06/2006 | NEED NAIL PLATES , FINISH WASHER BOX , BOLT W/C FLANGES DOWN , REMOVE P-TRAPS AND USE GLUE TRAPS , NEED APPROVED FITTINGS FOR SHOWER VALVES TEST ALL OF WATER PIPES THROUGH SHOWERS | TCRIPPEN | TCRIPPEN | | PTO | P | 3075657 |
HOMEOWNER | PB | C | 08/17/2005 | OK FOUR INCH DRAIN VENTED FLOOR DRAIN | TCRIPPEN | TCRIPPEN | | PB | C | 3075651 |
HOMEOWNER | PB | P | 08/16/2005 | NEED VENT FOR W/C BY BACK WALL , NEED VENT FOR TUB BY GARAGE , LOWER DRAIN WILL BE IN CONCREATE AT THIS TIME STEAK ALL EXPOSED DRAIN LINES ABOVE DITCH NO WATER AT THIS TIME | TCRIPPEN | TCRIPPEN | | PB | P | 3075644 |