COLARELLI CONSTRUCTION, INC. | BSP | T | 03/10/2009 | ADDITIONAL PLAN REVIEW TIME: $50 From: SHELBY to show stairs not on original plan | SHELBY | SHELBY | | BSP | T | 3811153 |
COLARELLI CONSTRUCTION, INC. | BSP | T | 03/06/2009 | ADDITIONAL PLAN REVIEW TIME: $50 From: SHELLEY added stair, hall modification and restaurant partition | SHELLEY | SHELLEY | | BSP | T | 3809717 |
COLARELLI CONSTRUCTION, INC. | BE | C | 03/13/2008 | Re-Issued for FULL of Permit Fee on 13-mar-2008 | BPHILLIPS | BPHILLIPS | | BE | C | 3176437 |
COLARELLI CONSTRUCTION, INC. | B= | T | 03/02/2007 | PAID (REC#796469)NO CORRECTION; ADDITIONAL WORK DONE FOR ADDING A SOUTH EXIT AT LARGE EVENT CENTER NOT ON PLANS | DANF | DANF | | B= | T | 3176429 |
COLARELLI CONSTRUCTION, INC. | BE | C | 02/20/2007 | Re-Issued for FULL of Permit Fee on 20-feb-2007 | MINDY | MINDY | | BE | C | 3176421 |
COLARELLI CONSTRUCTION, INC. | B= | R | 02/10/2006 | 1) MISSING ADA BATHROOM SIGNAGE 2) MISSING EXIT SIGN IN CALL CENTER 3) EXISTING EXIT SIGN NOT LUMINATED 4) CONTRACTOR DID NOT REMOVE WALL AND NOW HAVE EXITING THROUGH A ROOM | DANF | DANF | | B= | R | 3176413 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 01/19/2006 | BATHROOM FRAMING OK TO ROCK - NEED ACCESS IN HARD LID - CHECK AT FINAL | MICHAELA | MICHAELA | | BFR | P | 3176405 |
COLARELLI CONSTRUCTION, INC. | B= | P | 01/19/2006 | BAR AREA ONLY | MICHAELA | MICHAELA | | B= | P | 3176397 |
COLARELLI CONSTRUCTION, INC. | B= | P | 12/23/2005 | BOWLING ALLEY AREA ONLY OK, NEED ALL OTHER FINALS | JOHNP | JOHNP | | B= | P | 3176388 |
COLARELLI CONSTRUCTION, INC. | B= | R | 12/22/2005 | CONTRACTOR WANTED TCO FOR BOWELING AREA; 1) NEED CLEAR FRAME 2) FLOOR SYSTEM UNDER BOWELING LANES NO PLANS TJIS WERE USED NO INPSECTION 3) GUARDRAIL ON PLANS SHOW 42" HAVE 36" 4) MISSING ALL EXTERIOR AND INTERIOR HANDRAILS 5) 3/4" RISE DIFFERENCE AT TOP RISE STAIRS INSIDE 6) PLANS SHOW ONLY ONE EXIT TO EXTEIOR WHERE 2 ARE REQUIDRED 6) NEED PERMINENT OCCUPANCE SIGN | DANF | DANF | | B= | R | 3176380 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 12/12/2005 | RADIOUS WALLS AT BOWELING LOUGN AND SOFFET ACROSS FROM IT | DANF | DANF | | BFR | P | 3176373 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 11/30/2005 | NEED DETAIL FOR REAR BOWELING ALLEY SOFFET ATTACHEMNT TO ROOF DECK; NEED APPROVED PLANS AT SITE | DANF | DANF | | BFR | P | 3176364 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 11/22/2005 | CALL CENTER OFFICE WALLS; DEMISING WALL BETWEEN CALL CENTER AND BOWLING AREA | DANF | DANF | | BFR | P | 3176356 |
RYBA ELECTRIC, INC. | E= | C | 02/07/2006 | | MIKEC | MIKEC | | E= | C | 3176348 |
RYBA ELECTRIC, INC. | E= | P | 01/12/2006 | SNACK BAR | MIKEC | MIKEC | | E= | P | 3176342 |
RYBA ELECTRIC, INC. | ER | C | 01/12/2006 | BATHROOMS | MIKEC | MIKEC | | ER | C | 3176334 |
RYBA ELECTRIC, INC. | ER | P | 01/05/2006 | DROPPED CEILING BAR AREA | MIKEC | MIKEC | | ER | P | 3176282 |
RYBA ELECTRIC, INC. | E= | P | 12/21/2005 | ALLEYS | MIKEC | MIKEC | | E= | P | 3176264 |
RYBA ELECTRIC, INC. | ER | P | 12/19/2005 | CEILING AREAS ENTRY, MECH ROOM HALLWAY | MIKEC | MIKEC | | ER | P | 3176235 |
RYBA ELECTRIC, INC. | E= | P | 12/16/2005 | CRUSH OFFICES | MIKEC | MIKEC | | E= | P | 3176228 |
RYBA ELECTRIC, INC. | ER | P | 12/14/2005 | REST OF BALL RETURNS | MIKEC | MIKEC | | ER | P | 3176220 |
RYBA ELECTRIC, INC. | ER | P | 12/06/2005 | OFFICE WALLS AND BALL RETURN FEEDS | MIKEC | MIKEC | | ER | P | 3176256 |
RYBA ELECTRIC, INC. | ER | P | 11/23/2005 | MAIN ALLEY CEILING | MIKEC | MIKEC | | ER | P | 3176212 |
RYBA ELECTRIC, INC. | ER | P | 11/23/2005 | MAIN ALLEY CEILING | MIKEC | MIKEC | | ER | P | 3176246 |
RYBA ELECTRIC, INC. | ER | P | 11/21/2005 | OFFICE WALLS | MIKEC | MIKEC | | ER | P | 3176204 |
HVAC SOLUTIONS, INC. | H= | C | 02/09/2006 | BATH ROOMS AT DOCK AREA OK. HVAC FINAL. | LYNNS | LYNNS | | H= | C | 3176475 |
HVAC SOLUTIONS, INC. | HD | C | 01/24/2006 | BATH EXHAUST AND TRANFER DUCT OK IN DOCK AREA. | LYNNS | LYNNS | | HD | C | 3176467 |
HVAC SOLUTIONS, INC. | H= | P | 12/19/2005 | CONCESSION AND SITTING AREA OF BOWLING ALLEY OK FOR TILE | JACK | JACK | | H= | P | 3176459 |
HVAC SOLUTIONS, INC. | HD | P | 11/23/2005 | DUCT RAISED AND FLEXS ON AHU-S5. | LYNNS | LYNNS | | HD | P | 3176451 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 02/09/2006 | | LEE | LEE | | P= | C | 3176196 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 01/18/2006 | SOUTH RESTROOM WALLS ONLY, DWV & H20 OK | LEE | LEE | | PTO | P | 3176188 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 01/11/2006 | BAR AREA OK | LEE | LEE | | P= | P | 3176180 |
LANDMARK PLUMBING AND HEATING, INC. | PB | C | 01/03/2006 | BAR AREA FLOOR SINK AND HAND SINK OK | LEE | LEE | | PB | C | 3176173 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 12/20/2005 | FOR BOWLING ALLEY AREA | LEE | LEE | | P= | P | 3176164 |
LANDMARK PLUMBING AND HEATING, INC. | PB | P | 12/15/2005 | 3" STACK AT D/F TO HAVE ACCESSABLE 3" C/O AT FINAL (RESTROOMS) | LEE | LEE | | PB | P | 3176157 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 12/15/2005 | CALL CENTER BREAK SINK COMPLETE, STILL NEED RESTROOMS | LEE | LEE | | PTO | P | 3176149 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 12/01/2005 | BREAK SINK WALL ONLY (CALL CENTER) | LEE | LEE | | PTO | P | 3176141 |
LANDMARK PLUMBING AND HEATING, INC. | PB | P | 12/01/2005 | ONE 2" DRAIN (FOR CALL CENTER BREAK SINK) | LEE | LEE | | PB | P | 3176133 |