DANIEL-BARRY CONSTRUCTION INC | B= | C | 06/07/2007 | UNITS-A-B-C-D-E/WATERMETER INSTALLED/FIRE FINAL IN COMPUTER/NO BASEMENT | BERTW | BERTW | | B= | C | 3250248 |
DANIEL-BARRY CONSTRUCTION INC | BIN | C | 03/05/2007 | | TERRYB | TERRYB | | BIN | C | 3250243 |
DANIEL-BARRY CONSTRUCTION INC | BFR | P | 03/01/2007 | UNITS A-B-C-D-E OK TO INSULATE/UNIT D NEED COMMON WALL SHEETROCK @ STAIRWELL WALL SECOND FLOOR-IT IS MISSING AND OR BROKEN OFF IN MANY AREAS | BERTW | BERTW | | BFR | P | 3250237 |
DANIEL-BARRY CONSTRUCTION INC | BSP | P | 02/07/2007 | POINT LOADS TO FOUNDATION OK AND FIRECAULKING OK UNITS A AND B | BERTW | BERTW | | BSP | P | 3250229 |
DANIEL-BARRY CONSTRUCTION INC | BLA | C | 12/28/2006 | | BERTW | BERTW | | BLA | C | 3250221 |
DANIEL-BARRY CONSTRUCTION INC | BSP | P | 09/11/2006 | RIM AT CANTILEVER NEEDS L90'S SEE SHEET S.4 | TERRYB | TERRYB | | BSP | P | 3250213 |
DANIEL-BARRY CONSTRUCTION INC | BSP | P | 07/25/2006 | FIREWALL FIRST FLOOR | TERRYB | TERRYB | | BSP | P | 3250205 |
DANIEL-BARRY CONSTRUCTION INC | BFI | C | 04/12/2006 | | TERRYB | TERRYB | | BFI | C | 3250198 |
DANIEL-BARRY CONSTRUCTION INC | BFN | C | 04/05/2006 | UFER IN | TERRYB | TERRYB | | BFN | C | 3250189 |
DANIEL-BARRY CONSTRUCTION INC | BFT | C | 04/04/2006 | | TERRYB | TERRYB | | BFT | C | 3250182 |
DANIEL-BARRY CONSTRUCTION INC | BSP | P | 04/03/2006 | PICKED UP LETTER FOR OVERDIG | TERRYB | TERRYB | | BSP | P | 3250174 |
SCOTT ENTERPRISES, LTD. | E= | C | 06/07/2007 | REMOVE TEMP SERVICES. CONTRACTOR SAID HE HAS CALLED CSPU | BRET | BRET | | E= | C | 3250417 |
SCOTT ENTERPRISES, LTD. | ES | C | 03/29/2007 | COMMERCIAL SERVICE: 400 AMP 3/WIRE SERVICE BY SCOTT ENTERPRISES NEED METER SET ON 5 APT AND ONE HOUSE PANEL CONTRACTOR TO COORDINATE | BRET | BRET | | ES | C | 3250408 |
SCOTT ENTERPRISES, LTD. | ER | C | 02/28/2007 | | BRET | BRET | | ER | C | 3250400 |
SCOTT ENTERPRISES, LTD. | ER | P | 02/15/2007 | UPPER 103---201---203 PLUS FIRE ALARM | THOMAS | THOMAS | | ER | P | 3250392 |
HVAC SOLUTIONS, INC. | H= | C | 05/07/2007 | MECHANICAL COMPLETE | DOUGR | DOUGR | | H= | C | 3250383 |
LANDMARK PLUMBING AND HEATING, INC. | HC | C | 05/04/2007 | OK TO SET ALL 5 METERS | DOUGR | DOUGR | | HC | C | 3250309 |
LANDMARK PLUMBING AND HEATING, INC. | HI | C | 05/04/2007 | | DOUGR | DOUGR | | HI | C | 3250303 |
LANDMARK PLUMBING AND HEATING, INC. | H= | C | 05/04/2007 | GAS FINAL ONLY | DOUGR | DOUGR | | H= | C | 3250297 |
LANDMARK PLUMBING AND HEATING, INC. | HI | R | 05/03/2007 | ALL TESTS ON 5 1\2 TO 6 LBS, SHORTEN NIPPLE ON UNIT 103 SO GAS DOESN'T BLOCK EQUIPMENT ACCESS, REPIPE UNIT 202 SO WATER HEATER CAN MOVE BACK, EXSPOSE SLEEVES ON CSST THRU CONCRETE | DOUGR | DOUGR | | HI | R | 3250292 |
HVAC SOLUTIONS, INC. | H= | R | 05/03/2007 | UNIT C - AKA 103 VENT NEVER RECALLED & NOW COVERED SO INSPECTOR CAN'T VERIFY CLEARENCE, UNIT 101 NEEDS FACTORY MOUNTING BRACKET ON DRYER BOOSTER FAN, UNIT 202 WATER HEATER NEEDS MOVED BACK - ONLY 12'' IN FRONT OF WASHER | DOUGR | DOUGR | | H= | R | 3250375 |
HVAC SOLUTIONS, INC. | HD | P | 02/23/2007 | A & B COMPLETED, STILL NEED TO SEE ATTIC DUCTS INSULATED | DOUGR | DOUGR | | HD | P | 3250367 |
HVAC SOLUTIONS, INC. | HV | P | 02/13/2007 | UNIT C EXTEND VENT THRU CEILING - ROOFING TOUCHING VENT - DRYWALL AT FIRESTOP ABOVE MECH ROOM CEILING TO CLOSE TO VENT ON SIDE | DOUGR | DOUGR | | HV | P | 3250362 |
HVAC SOLUTIONS, INC. | HV | T | 02/06/2007 | PAID (REC#736264)SEE HD NOTES FOR F82072 DATED 2 \ 6 \ 07 | DOUGR | DOUGR | | HV | T | 3250356 |
LANDMARK PLUMBING AND HEATING, INC. | HI | P | 01/30/2007 | 4- CSST LINES THROUGH BUILDING. WILL RECALL WITH TEST AND SLEEVE INSPECTION AT 2 LOCATIONS THROUGH FLOORS. | JON | JON | | HI | P | 3250285 |
LANDMARK PLUMBING AND HEATING, INC. | HI | R | 01/25/2007 | CONTRACTOR HAS BEEN TOLD MANY TIMES - NO MORE INSPECTIONS UNTIL ALL UNITS HAVE ADDRESSES ON EACH UNIT | DOUGR | DOUGR | | HI | R | 3250276 |
LANDMARK PLUMBING AND HEATING, INC. | H= | R | 01/25/2007 | NOTHING READY FOR FINALS | DOUGR | DOUGR | | H= | R | 3250270 |
HVAC SOLUTIONS, INC. | HV | R | 01/11/2007 | NOT READY, NO UNITS MARKED, CHASES NOT BUILT, CALL ENTIRE BUILDING IN AT ONCE AS THERE IS ONLY 1 PERMIT OR REINSPECTION FEES WILL BE APPLIED TO PAY FOR EXTRA INSPECTIONS | DOUGR | DOUGR | | HV | R | 3250347 |
HVAC SOLUTIONS, INC. | HD | P | 12/11/2006 | INSPECTED DUCTS UNITS C,D & E | DAVIDH | DAVIDH | | HD | P | 3250339 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 05/21/2007 | | MARTY | MARTY | | P= | C | 3250332 |
LANDMARK PLUMBING AND HEATING, INC. | P= | R | 05/18/2007 | UNCROSS FIXTURES. | MARTY | MARTY | | P= | R | 3250327 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | C | 02/01/2007 | | MARTY | MARTY | | PTO | C | 3250321 |
LANDMARK PLUMBING AND HEATING, INC. | PB | C | 07/12/2006 | | ELDON | ELDON | | PB | C | 3250315 |