BEAZER HOMES HOLDING CORP. | B= | C | 05/01/2007 | FINISHED BASEMENT | MICHAELA | MICHAELA | | B= | C | 3294282 |
BEAZER HOMES HOLDING CORP. | B= | R | 04/19/2007 | DRYWALL IN FRONT GARAGE ALL WALLS ADJACENT TO COVERED PORCH / WRAP EXPOSED STEEL BEAM IN CLOSET UNDER BASEMENT STAIRS / INSTALL LANDING AT REAR DECK STAIRS / EXTEND SUMP PIPING TO 5' FROM STRUCTURE | MICHAELA | MICHAELA | | B= | R | 3294275 |
BEAZER HOMES HOLDING CORP. | BFR | P | 08/09/2006 | STILL NEED ENGINEERING ON 1 CAR FOUNDATION BREAK OUT | SEANA | SEANA | | BFR | P | 3294269 |
BEAZER HOMES HOLDING CORP. | BIN | C | 08/09/2006 | | SEANA | SEANA | | BIN | C | 3294262 |
BEAZER HOMES HOLDING CORP. | BFR | R | 08/04/2006 | NEED ADDITIONAL UPLIFT HRDWR @ T04X-T01X-T032-T03Y, NEED LATERALS @ M01F'S-T01G-T01K-T01B-T01D-T03Y, NEED STRUTS @ LATERAL BRACING, NEED 2- H2.5 @ T02 EACH END, BLOCK GARAGE DOOR BRACKETS, DRAFT STOP AROUND VENTS BEHIND FIREPLACE, NEED ENGINEERING FOR 1 CAR FOUNDATION BREAKOUT (GROUTED WITHOUT REPAIR), OK TO INSULATE | SEANA | SEANA | | BFR | R | 3294254 |
BEAZER HOMES HOLDING CORP. | BSP | P | 07/07/2006 | FRONT PORCH FRAME/POSTS & SHEAR OK | SEANA | SEANA | | BSP | P | 3294246 |
BEAZER HOMES HOLDING CORP. | BFD | C | 05/24/2006 | BFT/BFN INSPECTION REPORT - DESIGN - SOILS ON FILE | SEANA | SEANA | | BFD | C | 3294238 |
BEAZER HOMES HOLDING CORP. | BFD | R | 05/23/2006 | NEED TO DAMPROOF ALL FOUNDATION W/O DRAIN, SEE SOILS | SEANA | SEANA | | BFD | R | 3294230 |
BEAZER HOMES HOLDING CORP. | BFN | P | 04/12/2006 | WEINTRAUB WILL PERFORM FOOTER AND FOUNDATION INSPECTION. | OWEN | OWEN | | BFN | P | 3294214 |
BEAZER HOMES HOLDING CORP. | BFT | P | 04/12/2006 | WEINTRAUB WILL PERFORM FOOTER AND FOUNDATION INSPECTION. | OWEN | OWEN | | BFT | P | 3294222 |
HOUSTON-STAFFORD ELEC. CONTR. | E= | C | 11/06/2006 | | ROBERT | ROBERT | | E= | C | 3294328 |
HOUSTON-STAFFORD ELEC. CONTR. | ES | C | 11/06/2006 | RESIDENTIAL UNDERGROUND: 200 AMP 3W NEW HOME BY HOUSTON-STAFFORD. RESEAL | ROBERT | ROBERT | | ES | C | 3294321 |
TEKOTA ELECTRIC, INC. | E= | R | 09/28/2006 | SEE SERVICE NOTES! | DAVID | DAVID | | E= | R | 3294133 |
TEKOTA ELECTRIC, INC. | ES | T | 09/28/2006 | PAID (REC#720544)LOCKED! | DAVID | DAVID | | ES | T | 3294125 |
TEKOTA ELECTRIC, INC. | E= | R | 09/27/2006 | CAP NEUTRAL AT AC DISCONNECT, PROTECT HORIZONTAL ROMEX IN MECH ROOM, CALL FOR SERVICE INSPECTION=====AC PREWIRE==== | ROBERT | ROBERT | | E= | R | 3294174 |
TEKOTA ELECTRIC, INC. | EUG | C | 08/08/2006 | 4/0 USE OK TO COVER. | ROBERT | ROBERT | | EUG | C | 3294165 |
TEKOTA ELECTRIC, INC. | EUG | R | 08/02/2006 | CONDUCTORS NOT 2' DEEP NEAR HOUSE | GARY | GARY | | EUG | R | 3294157 |
TEKOTA ELECTRIC, INC. | ES | R | 08/02/2006 | SEE EUG | GARY | GARY | | ES | R | 3294149 |
TEKOTA ELECTRIC, INC. | ER | C | 07/20/2006 | FINISHED BASEMENT | THOMAS | THOMAS | | ER | C | 3294141 |
FRIEND GROUP, INC. | H= | C | 10/13/2006 | FINISHED BASEMENT. A/C COMPLETE | ERIC | ERIC | | H= | C | 3294314 |
FRIEND GROUP, INC. | HC | C | 08/03/2006 | OK FOR METER | ERIC | ERIC | | HC | C | 3294306 |
FRIEND GROUP, INC. | HRR | C | 08/03/2006 | CORRECTIONS MADE | ERIC | ERIC | | HRR | C | 3294297 |
FRIEND GROUP, INC. | HRR | P | 07/27/2006 | PROVIDE FURN INSTALL GUIDE FOR VENT CLEARANCE TO OSA INTAKE, PAN OFF RETURN BAYS AT SOFFIT IN BASEMENT, SEAL GAP AT DRYER ROOF TERMINATION. NOTE FIN BSMNT WITH A/C ROUGH | TOMS | TOMS | | HRR | P | 3294289 |
CHIEF HEATING AND GAS CORP. | HI | C | 07/18/2006 | 1" FURNACE WATERHEATER FIREPLACE | TIM | TIM | | HI | C | 3294205 |
B & L PLUMBING, INC. | P= | C | 10/12/2006 | | ELDON | ELDON | | P= | C | 3294197 |
B & L PLUMBING, INC. | PTO | C | 07/20/2006 | | TIM | TIM | | PTO | C | 3294190 |
B & L PLUMBING, INC. | PB | C | 05/31/2006 | 4" | JEFF | JEFF | | PB | C | 3294181 |