RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/02/2024 | ANNUAL 10/23 - KONE W/PEAK LOCKBOX - ELEVATOR CAR MUST HAVE AUDIBLE DIRECTIONAL INDICATORS. / HIOSTWAY ACCESS KEY CYLINDER ON 2ND FLOOR HOISTWAY JAMB IS NOT FUNCTIONING. / BUILDING PERSONNEL TO MAINTAIN WRITTEN ELEVATOR MONTHLY FIRE FIGHTERS SERVICE TESTING AND ELEVATOR QUARTERLY EMERGENCY PHONE TESTING LOGS PER STATE OF COLORADO CONVEYANCE REGULATIONS........60 DAYS TO ADDRESS........ (Receipt #2048750) | MATTM | MATTM | | H01 | C | 8039476 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/04/2023 | WITNESSED AT H02 (Receipt #1995027) | DUSTINS | DUSTINS | | H02 | C | 7877103 |
RECOVERY VILLAGE AT PALMER LAKE | H06 | C | 10/04/2023 | WITNESSED HYDRO SAFETY TESTING WITH PEAK -- KONE W/ PEAK LOCKBOX -- / HOISTWAY ACCESS SWITCHES NOT WORKING / PIT LIGHT OUT / EMERGENCY PHONE OPERATOR IDENTIFIES ADDRESS AS 105 HWY 105 AND NEEDS TO BE 443 HWY 105 / NEED TO PROVIDE COMPLETE MCP WITHIN IN MACHINE ROOM / BUILDING TO KEEP MONTHLY FIREFIGHTERS’ EMERGENCY OPERATION AND QUARTERLY EMERGENCY PHONE TEST LOGS UP TO DATE / 60 DAYS TO ADDRESS (Receipt #1995026) | DUSTINS | DUSTINS | | H06 | C | 7877102 |
RECOVERY VILLAGE AT PALMER LAKE | HE16 | C | 05/05/2023 | RE-INSPECTION RESULTED IN ALL ITEMS BEING ADDRESSED - PERMIT TO OPERATE EMAILED (Moved H06 to align with H02, DS) | MIKEM | MIKEM | | HE16 | C | 7737112 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/05/2023 | ANNUAL - 10/2022 - KONE WITH PEAK SERVICE -/ EMERGENCY TWO WAY COMMUNICATION IS NON-OPERABLE (MULTIPLE NOTICES) -/ EMERGENCY LIGHT AND BELL ARE NON-OPERABLE (MULTIPLE NOTICES) -/ CAR TOP LIGHT IS BROKEN AND NEEDS TO BE ADDRESSED -/ DUCT COVERS ARE OFF ON THE CAR TOP AND NEED TO BE RE-INSTALLED -/ OPEN AND CLOSE BUTTONS ARE BROKEN AND NEED TO BE REPLACED (MULTIPLE NOTICES) -/ PERMIT TO OPERATE WILL NOT BE ISSUED UNTIL ITEM/S ARE ADDRESSED -/ 30 DAYS TO ADDRESS TO AVOID AN ELEVATOR RED TAG NOTICE AND POSSIBLE SERVICE INTERRUPTION (Receipt #1944615) | MIKEM | MIKEM | | H01 | C | 7707371 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/20/2022 | HO2 -- ANNUAL 5/22 -- KONE W/ PEAK SERVICE -- SEE PREVIOUS NOTES cat 1 10/22 | BENH | BENH | | H02 | C | 7556455 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/05/2022 | CAT 1 -- 4/21 -- KONE W/ PEAK SERVICE -- / EMERGENCY LIGHT, ALARM BELL AND PHONE NON FUNCTIONAL WITH 110V DISCONNECTED / CLEAN MACHINE ROOM / MISSING FLOOR DESIGNATION NUMBERING/BRAILLE IDENTIFICATION AT BOTH FRONT ENTRANCES / CAR TOP LIGHT NOT WORKING / DIRECTIONAL LANTERN AUDIBLE NOT WORKING / DOOR OPEN AND CLOSE BUTTONS FOR FRONT AND REAR DOORS ARE BROKEN / CATEGORY 1 TESTING DUE BY THE END OF THE MONTH / (Receipt #1855956) (cat 1 -- 5/22, check previous items at next inspection. parts ordered per contractor report) | DUSTINS | DUSTINS | | H01 | C | 7325933 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/12/2021 | HO2 -- ANNUAL 4/21 -- KONE W/ PEAK SERVICE -- CHECK PREVIOUS LISTED ITEMS AT HO1 | BENH | BENH | | H02 | C | 7138832 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/14/2021 | ANNUAL 4/2021 -- KONE W/ PEAK SERVICE -- / EMERGENCY PHONE OPERATOR UNABLE TO IDENTIFY BUILDING LOCATION / CLEAN MACHINE ROOM / MISSING FLOOR DESIGNATION NUMBERING/ BRAILLE IDENTIFICATION AT FRONT ENTRANCES / FRONT AND REAR HOISTWAY DOOR SIDE RETAINERS AT UPPER LANDINGS ARE LOOSE (Receipt #1764725) cat 1 4/21 | RANDYB | RANDYB | | H01 | C | 6934044 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/22/2020 | RP 12/19 KONE, PEAK SERVICE, HO2 | ERIC | ERIC | | H02 | C | 6751384 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/21/2020 | CAT. 1 PERFORMED 12/2019 -- KONE W/ PEAK SERVICE -- MISSING FLOOR IDENTIFICATION PLAQUES AT TOP AND BOTTOM FLOOR FRONT ENTRIES / TOP FLOOR FRONT AND REAR HOISTWAY DOORS, SIDE RETAINERS ARE LOOSE / UPON ACTUATING PHASE 1 FIRE FIGHTERS SERVICE THE IN CAR AUDIBLE SIGNAL DOES NOT SOUND. (Receipt #1675047) | RANDYB | RANDYB | | H01 | C | 6546217 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/21/2019 | RP--11--18--KONE --PEAK SERVICE (Cat 1 performed 12/2019) | JOHNW | JOHNW | | H02 | C | 6374572 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/24/2019 | RP--11--18--KONE --PEAK SERVICE --PHONE IN CAB NOT WORKING (Receipt #1593132) | JOHNW | JOHNW | | H01 | C | 6176874 |
RECOVERY VILLAGE AT PALMER LAKE | H06 | C | 11/21/2018 | WITNESSED 5YR HYDRO SAFETY TEST 11/21/18--KONE--PEAK SERVICE | CALE | CALE | | H06 | C | 6032432 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/15/2018 | RP--12--17--KONE --PEAK SERVICE --EMERGENCY LIGHT AND ALARM NOT WORKING | JOHNW | JOHNW | | H02 | C | 5994224 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/12/2018 | RP--12--17--KONE -PEAK --EMERGENCY LIGHT AND ALARM IN CAB NOT WORKING | JOHNW | JOHNW | | H01 | C | 5814693 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/17/2017 | RP--9--16--KONE --PEAK SERVICE --RELIEF PRESSURE TEST EXPIRED | JOHNW | JOHNW | | H02 | C | 5657529 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/19/2017 | RP--9--16--KONE --ANNUAL TEST REPORT NOT WITH THE MCP IN MACHINE ROOM (Receipt #1418206) | JOHNW | JOHNW | | H01 | C | 5479635 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/10/2016 | RP--9--16--KONE --PEAK SERVICE--HO2 | JOHNW | JOHNW | | H02 | C | 5313944 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 04/26/2016 | RP--6--15--KONE --PH 1 KEYED SWITCH IS LOOSE AT THE WALL (Receipt #1325823) | JOHNW | JOHNW | | H01 | C | 5184333 |
RECOVERY VILLAGE AT PALMER LAKE | H02 | C | 10/27/2015 | RP 6/15 H02 | ERIC | ERIC | | H02 | C | 5066048 |
RECOVERY VILLAGE AT PALMER LAKE | H01 | C | 05/26/2015 | PRESSURE RELIEF TEST EXPIRED (Receipt #1263759) completed 6/5/15 | JOHNW | JOHNW | | H01 | C | 4960273 |
INN AT PALMER DIVIDE | H02 | C | 10/20/2014 | RP--10--13--KONE | JOHNW | JOHNW | | H02 | C | 4837631 |
INN AT PALMER DIVIDE | H01 | C | 04/07/2014 | 5 YR WITNESSED TEST PERFORMED IN OCT OF 2013 (Receipt #1187899) | JOHNW | JOHNW | | H01 | C | 4715742 |
INN AT PALMER DIVIDE | H06 | C | 10/21/2013 | WITNESSED 5 YEAR HYDRO SAFETY TEST. ALARM BELL AND EMERGENCY LIGHTS NOT WORKING | ERIC | ERIC | | H06 | C | 4625921 |
INN AT PALMER DIVIDE | H02 | C | 10/04/2013 | RP---11--11--KONE --CENTRIC SERVICE --PRESSURE RELIEF TEST EXPIRED WAY OVER DUE MUST PERFORM TEST NOW WILL FOLLOW UP NEXT MONTH | JOHNW | JOHNW | | H02 | C | 4616734 |
INN AT PALMER DIVIDE | H01 | C | 04/03/2013 | RP--11--11--KONE--ELEVATOR STILL BEING SERVICED BY CENTRIC?--PRESSURE RELIEF TEST EXPIRED AND CENTRIC STILL NOT LICENSED WITH REGIONAL BUILDING DEPARTMENT (Receipt #1120971) | JOHNW | JOHNW | | H01 | C | 4498778 |
INN AT PALMER DIVIDE | H02 | C | 10/19/2012 | RP--11-=-11--KONE | JOHNW | JOHNW | | H02 | C | 4405148 |
INN AT PALMER DIVIDE | H01 | C | 04/27/2012 | RP--11--11--KONE--CENTRIC SERVICE (CENTRIC IS NOT LIC IN COLO SPGS) (Receipt #1041864) | JOHNW | JOHNW | | H01 | C | 4303041 |
INN AT PALMER DIVIDE | H02 | C | 10/27/2011 | RP--3--10--KONE --PRESSURE RELIEF TEST EXPIRED. TEST MUST BE COMPLETED WITHIN 30 DAYS | JOHNW | JOHNW | | H02 | C | 4227625 |
INN AT PALMER DIVIDE | H01 | C | 04/29/2011 | RP-3--10--KONE CENTRIC SERVICE --PRESSURE RELIEF EXPIRED (Receipt #972213) | JOHNW | JOHNW | | H01 | C | 4142982 |
INN AT PALMER DIVIDE | H02 | C | 10/26/2010 | RP 3/10 KONE. CENTRIC ELEVATOR SERVICE | ERIC | ERIC | | H02 | C | 4061895 |
INN AT PALMER DIVIDE | H01 | C | 04/21/2010 | RP--3--10--KONE (Receipt #905762) | JOHNW | JOHNW | | H01 | C | 3970586 |
INN AT PALMER DIVIDE | H02 | C | 10/19/2009 | RP--12--08--KONE
| JOHNW | JOHNW | | H02 | C | 3899946 |
INN AT PALMER DIVIDE | H01 | C | 04/16/2009 | KONE RP 12/08 (Receipt #854394) | ERIC | ERIC | | H01 | C | 3824631 |
INN AT PALMER DIVIDE | H02 | C | 10/02/2008 | RP EXPIRED --- KONE ELEVATOR | LES | LES | | H02 | C | 3749985 |
INN AT PALMER DIVIDE | H01 | C | 04/11/2008 | RP--4--07--KONE--FIRE EXTINGUISHER EXPIRED | JOHNW | JOHNW | | H01 | C | 3302331 |
INN @ PALMER DIVIDE | H02 | C | 10/05/2007 | RP--4--06--KONE | JOHNW | JOHNW | | H02 | C | 3302323 |
INN @ PALMER DIVIDE | H01 | C | 04/17/2007 | RP--4--06--KONE | JOHNW | JOHNW | | H01 | C | 3302316 |
INN @ PALMER DIVIDE | H02 | C | 10/16/2006 | RP--4--06--KONE--PHONE INOP | JOHNW | JOHNW | | H02 | C | 3302307 |
INN @ PALMER DIVIDE | H01 | C | 04/28/2006 | INITIAL INSPECTION--PERMIT ISSUED--KONE | TOM | TOM | | H01 | C | 3302299 |