HANDCRAFTED CONSTRUCTION INC | B= | C | 08/02/2007 | | RONG | RONG | | B= | C | 3385370 |
HANDCRAFTED CONSTRUCTION INC | BLA | C | 03/20/2007 | | RONG | RONG | | BLA | C | 3385305 |
HANDCRAFTED CONSTRUCTION INC | BIN | C | 03/01/2007 | | RONG | RONG | | BIN | C | 3385361 |
HANDCRAFTED CONSTRUCTION INC | BFR | C | 03/01/2007 | ENG. LETTERS ON FILE. | RONG | RONG | | BFR | C | 3385354 |
HANDCRAFTED CONSTRUCTION INC | BFR | P | 02/26/2007 | NEED ENG FIX FOR H-BEAMS UPPER FLOOR./ NEED ENG LETTER FOR BASEMENT WINDOW CHANGE. | RONG | RONG | | BFR | P | 3385345 |
HANDCRAFTED CONSTRUCTION INC | BFR | R | 02/25/2007 | WANT ENG FOR ATTACHMENT AT THE H BEAMS UPPER TRUSS SUPPORT AND D1 THR D8 AND K TRUSS HUNG OFF TIMBERSTRAND-BLOCK TOPS EJ1-FIRESTOPS-CLIP HIP MASTER AND JACKS-ADD 2X4 SUPPORT F1G-MISSING ATTIC ACCESS-DADD 2X6 AT D1G-POINT LOADS F1G GIRDER-BEARING BLOCKS F1G-STRAP LANDING-BLOCK CANTILEVERS-MISSING POSTS AT M/L BASEMENT-ENG FOR THE HEADER AT WINDOW BASEMENT-CLIPS AT FLLOR WHERE HEADED OF- STRAPS AT THE CUT PLATES THROUGHOUT---DID NOT DO THE POINT LOADS IN THIS HOUSE | GREGC | GREGC | | BFR | R | 3385337 |
HANDCRAFTED CONSTRUCTION INC | BSP | P | 09/13/2006 | EXTERIOR PIERS OK | GREGC | GREGC | | BSP | P | 3385329 |
HANDCRAFTED CONSTRUCTION INC | BFI | C | 09/01/2006 | | DALE | DALE | | BFI | C | 3385294 |
HANDCRAFTED CONSTRUCTION INC | BFD | C | 08/30/2006 | | GREGC | GREGC | | BFD | C | 3385321 |
HANDCRAFTED CONSTRUCTION INC | BFN | C | 08/18/2006 | FOUNDATION DESIGN ON FILE / UFER IN / INTERIOR PADS OK / USABLE / SOILS ON FILE | DALE | DALE | | BFN | C | 3385286 |
HANDCRAFTED CONSTRUCTION INC | BFT | C | 08/10/2006 | NO INTERIOR PADS READY | GREGC | GREGC | | BFT | C | 3385313 |
PORCH ELECTRIC, INC. | E= | C | 07/19/2007 | | ROBERT | ROBERT | | E= | C | 3385230 |
PORCH ELECTRIC, INC. | E= | R | 07/16/2007 | WHIRLPOOL ACCESS, ARC FAULT SITTING ROOM OFF MASTER, SECURE MAIN BATH GFI======AC PREWIRE===== | ROBERT | ROBERT | | E= | R | 3385222 |
PORCH ELECTRIC, INC. | ER | C | 02/22/2007 | FIREPLACE WIRED, UNFINISHED BASEMENT, 100 AMP SUB BASEMENT. | ROBERT | ROBERT | | ER | C | 3385214 |
PORCH ELECTRIC, INC. | ER | R | 02/21/2007 | RELOCATE 2 RECEPTS BEHIND KITCHEN SINK, ONE SHOULD BE UNDER EACH WINDOW SO NONE ARE OVER 4FT APART, IS THERE A WALL BEING FRAMED IN BACK OF UPPER CLOSET? NEED ANSWER. | DEAN | DEAN | | ER | R | 3385206 |
PORCH ELECTRIC, INC. | ES | C | 02/20/2007 | RESIDENTIAL UNDERGROUND: 200-AMP 3 WIRE NEW SERVICE BY PORCH ELEC. | DEAN | DEAN | | ES | C | 3385199 |
PORCH ELECTRIC, INC. | ER | R | 02/20/2007 | ADD RECETPS BEHIND KITCHEN SINK PER CODE, ROMEX SHEATH NOT INTO BOX AT MASTER CLOSET WASHER, ROMEX NOT 1.25IN FROM FACE OF STUDS AT CEILING OF BATH IN FRONT ROOM BY FRONT DOOR, WHAT WILL PROTECT ROMEX AT FLOOR OF UPPER LEFT BD RM CLOSET? ----------------------8/3CU TO OVEN AND 10/3 TO COOKTOP-------------------UNFINISHED BASEMENT--------------------100-AMP SUB OK-------------------- | DEAN | DEAN | | ER | R | 3385191 |
PORCH ELECTRIC, INC. | EUG | C | 09/12/2006 | 4/0 USE OK TO COVER. | ROBERT | ROBERT | | EUG | C | 3385181 |
ARROW HAWK HEATING, LLC | H= | C | 07/26/2007 | NOTE: PARTIALLY FINISHED BASEMENT. | NANCY | NANCY | | H= | C | 3385262 |
ARROW HAWK HEATING, LLC | H= | P | 07/24/2007 | EXTEND DRYER VENT FURTHER OUT WALL OF CUT BASEBOARD TRIM BACK. NOTE: FINISHED BASEMENT. LOUVERED DOOR TO MECHANICAL ROOM. OUTSIDE AIR TO BOTH FURNACE RETURNS. A/C ROUGH, LINESET ONLY, TO MAIN FURNACE ONLY. | NANCY | NANCY | | H= | P | 3385254 |
O.M.A.G.M., INC. | HI | C | 02/15/2007 | FUTURE BBQ, COOKTOP AND GARAGE HEATER. 75,000 BTU'S FOR GARAGE. | NANCY | NANCY | | HI | C | 3385278 |
ARROW HAWK HEATING, LLC | HC | C | 02/15/2007 | OK FOR METER. | NANCY | NANCY | | HC | C | 3385246 |
ARROW HAWK HEATING, LLC | HRR | C | 02/15/2007 | NOTE: UNFINISHED BASEMENT. OUTSIDE AIR TO BOTH FURNACE RETURNS. | NANCY | NANCY | | HRR | C | 3385239 |
O.M.A.G.M., INC. | HI | P | 02/14/2007 | SECURE IN WALL GAS LINE TO DRYER. SECURE LINE GOING TO FIREPLACE SO IT DOES NOT MOVE AROUND. WHAT ARE THE EXTRA TEES AND ELBOWS WITH THE PLUGS FOR, FUTURE APPLIANCES? 10 LB TEST OK. 1 1/2 INCH LINE IN. 2 FURNACES, 2 WATER HEATERS, 1 FIREPLACE, 1 DRYER. NOTE: ONE FIREPLACE IS A WOOD BURNER. | NANCY | NANCY | | HI | P | 3385271 |
CITY WIDE PLUMBING, INC. | P= | C | 08/01/2007 | PARTIAL FINISHED BASEMENT. 1 BATHROOM AND A BAR. NO SPRINKLER BACKFLOW. RECIEVED POTABLE WATER CERTIFICATE | SCOTT | SCOTT | | P= | C | 3385172 |
HANDCRAFTED CONSTRUCTION INC | PWO | C | 03/13/2007 | NO PERMIT ON SITE. NEED POTABLE WATER REPORT BY FINAL. | SCOTT | SCOTT | | PWO | C | 3385377 |
CITY WIDE PLUMBING, INC. | PTO | C | 02/21/2007 | KITCHEN WILL HAVE STUDOR VENT IN APPROVED BOX UNDER SINK. UNFINISHED BASEMENT | SCOTT | SCOTT | | PTO | C | 3385164 |
CITY WIDE PLUMBING, INC. | PTO | P | 02/15/2007 | STUB OUT OF THE WALL FOR THE STUDOR VENT, ON KITCHEN SINK. UNFINISHED BASEMENT. | SCOTT | SCOTT | | PTO | P | 3385156 |
CITY WIDE PLUMBING, INC. | PB | C | 09/15/2006 | | SCOTT | SCOTT | | PB | C | 3385140 |
CITY WIDE PLUMBING, INC. | PB | R | 09/14/2006 | OPEN PIPE, NO TEST. UNVENTED FLOOR DRAIN EXCEEDS 15' SHOULD BE TRIP-FEE. | SCOTT | SCOTT | | PB | R | 3385148 |