CLASSIC RES CONSTR CO INC | B= | C | 01/10/2007 | WATER METER INSTALLED / UNFINISHED BASEMENT. | LEEG | LEEG | | B= | C | 3390761 |
CLASSIC RES CONSTR CO INC | BIN | C | 11/14/2006 | | LEEG | LEEG | | BIN | C | 3390753 |
CLASSIC RES CONSTR CO INC | BIN | R | 11/13/2006 | GARAGE CEILING-FLOOR JOIST NOT R-30 / MISSING BATTS AT UPPER FLOOR FIREPLACE CHASE WALL. | LEEG | LEEG | | BIN | R | 3390744 |
CLASSIC RES CONSTR CO INC | BFR | C | 11/08/2006 | | LEEG | LEEG | | BFR | C | 3390737 |
CLASSIC RES CONSTR CO INC | BFR | R | 11/07/2006 | CANCELLED BY STEVE. | LEEG | LEEG | | BFR | R | 3390728 |
CLASSIC RES CONSTR CO INC | BFR | R | 11/03/2006 | MISSING FIREPLACE FLUE COLLAR AT TOP OF CHASE / TIE OFF ENDS ALL LATERAL BRACES / MISSING 3 STUDS AT MICROLAM MID SPAN UPPER HALL / NEED 2ND ATTIC ACCESS UPPER ROOF / 3/4" PLYWOOD REINFORCEMENTS NOT NAILED PER PLAN AT REAR JOIST CANTILEVER / HEADER JOIST AT TUB DRAIN / FIRE STOP OPENINGS THRU FLOORS / WRONG HANGER AT MICRO TO MICRO CONNECTION ABOVE GARAGE / PLATE NOT ATTACHED TO STEEL BEAM PER PLAN AT GARAGE / GARAGE DOOR BRACKET PENETRATE DRYWALL / FLOAT BLOCKS / POINT LOADS | LEEG | LEEG | | BFR | R | 3390720 |
CLASSIC RES CONSTR CO INC | BSP | P | 10/23/2006 | PORCH FRAME OK | DALE | DALE | | BSP | P | 3390712 |
CLASSIC RES CONSTR CO INC | BFD | C | 09/20/2006 | | LEEG | LEEG | | BFD | C | 3390705 |
CLASSIC RES CONSTR CO INC | BFD | R | 09/19/2006 | REMOVE WOOD FROM INSIDE FOUNDATION. | LEEG | LEEG | | BFD | R | 3390697 |
CLASSIC RES CONSTR CO INC | BFD | R | 09/18/2006 | SOIL LETTER WITH INSPECTOR. DRAIN USEABLE / ISOLATE / FLOAT / GRADE 5%. REMOVE WOOD AND DEBRIS FROM INSIDE AND AROUND FOUNDATION / GROUT VOID UNDER PLATE SOUTH WALL. | LEEG | LEEG | | BFD | R | 3390688 |
CLASSIC RES CONSTR CO INC | BFN | C | 09/11/2006 | FOUNDATION DESIGN ON FILE / SOILS AT DRAIN | DALE | DALE | | BFN | C | 3390680 |
CLASSIC RES CONSTR CO INC | BFT | C | 09/07/2006 | FOUR PADS / 2400PSF./ ISOLATE / FLOAT | MELANIE | MELANIE | | BFT | C | 3390672 |
UNITED ELECTRIC OF COLORADO | E= | C | 01/02/2007 | NO AC, NO PREWIRES | THOMAS | THOMAS | | E= | C | 3390664 |
UNITED ELECTRIC OF COLORADO | ES | C | 11/02/2006 | RESIDENTIAL UNDERGROUND: 200 AMP 3 WIRE NEW SERVICE BY UNITED ELECTRIC OF COLORADO | THOMAS | THOMAS | | ES | C | 3390657 |
UNITED ELECTRIC OF COLORADO | ER | C | 11/02/2006 | UNFINISHED BASEMENT | THOMAS | THOMAS | | ER | C | 3390651 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 01/03/2007 | UNFINISHED BASEMENT, NO A/C. 6" OUTSIDE AIR TO RETURN. 4- SUPPLYS, 1- RETURN. | TOMS | TOMS | | H= | C | 3390643 |
KAMPP-L ENTERPRISES, INC. | HC | C | 11/01/2006 | RELEASE METER. | TOMS | TOMS | | HC | C | 3390790 |
KAMPP-L ENTERPRISES, INC. | HI | C | 11/01/2006 | 1" FURNACE/ WATER HEATER. | TOMS | TOMS | | HI | C | 3390783 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 11/01/2006 | BY FINAL: 3- SCREWS AT WATER HEATER INCREASER CONNECTION. NOTE: UNFINISHED BASEMENT WITH 7" OUTSIDE AIR TO RETURN. 4- SUPPLY, 1- RETURN. NO A/C. | TOMS | TOMS | | HRR | C | 3390635 |
KAMPP-L ENTERPRISES, INC. | P= | C | 12/26/2006 | NO IRRIGATION BACKFLOW | LEE | LEE | | P= | C | 3390813 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 10/25/2006 | UNFINISHED BASEMENT | JEFF | JEFF | | PTO | C | 3390805 |
KAMPP-L ENTERPRISES, INC. | PB | C | 09/15/2006 | | SCOTT | SCOTT | | PB | C | 3390797 |