HOMEOWNER | B= | C | 10/04/2007 | | JOND | JOND | | B= | C | 3423478 |
HOMEOWNER | B= | R | 09/26/2007 | NEED TO DRYWALL POSTS AND BEAM IN GARAGE, UNDER STAIRS, SEAL ALL PENETRATIONS, FINISH DRYWALL AT CEILING / HANDRAIL AT GARAGE STEPS / NEED 20MIN DOOR AND SEALED AT GARAGE DOOR | JOND | JOND | | B= | R | 3423470 |
HOMEOWNER | BFR | C | 09/14/2007 | FRAME IS COMPLETE, WHAT HOMEOWNER ACTUALLY WANTED WAS A B= | BLAKE | BLAKE | | BFR | C | 3423462 |
HOMEOWNER | B= | R | 09/14/2007 | NEED P=/ NEED H=/ SOUTH DECK HANDRAIL TOO WIDE | BLAKE | BLAKE | | B= | R | 3423454 |
HOMEOWNER | BSP | P | 09/05/2007 | FLOOR JOISTS FIXED ABOVE GARAGE / ENGINEER LETTER ON FILE | JOND | JOND | | BSP | P | 3423445 |
HOMEOWNER | BSP | R | 08/22/2007 | PAID (REC#767047)CUT JOIST GARAGE AT SHOWER P TRAP/SEE FRANK/THIS SHOULD HAVE NOT BEEN TRIP FEE,OWNER WOULD LIKE HIS MONEY BACK | FRANK | FRANK | | BSP | R | 3423437 |
HOMEOWNER | BFR | P | 04/06/2007 | NEED ALL ROUGHS SIGNED OFF / NEED ENGINEER LETTER ON DECK | JOND | JOND | | BFR | P | 3423429 |
HOMEOWNER | BIN | R | 04/06/2007 | NEED R-38 IN CEILING / THEY HAVE R-30, OK TO PUT ANOTHER INSULATION VALUE ON TOP | JOND | JOND | | BIN | R | 3423421 |
HOMEOWNER | BFR | R | 04/04/2007 | FIRESTOP / NEED ALL OTHER ROUGHS SIGNED OFF / DECK JOISTS NOT PER PLAN / NEED ENGINEER LETTER FOR PIER AND 2 NEW PADS IN GARAGE SAYING THEY LOOKED AT THEM / NEED INSULATION INSPECTION | JOND | JOND | | BFR | R | 3423413 |
HOMEOWNER | BFR | T | 12/12/2006 | PAID (REC#743899)NO DECK FRAME UP / NEED PLANS TO SHOW WHAT IS BUILT IN LOFT AREA (IE. KITCHEN WITH 220 POWER) / NEED ALL OTHER ROUGHS SIGNED OFF | JOND | JOND | | BFR | T | 3423405 |
HOMEOWNER | E= | C | 09/04/2007 | ------------------EXISTING LOWER GARAGE EXISTING NON-CONFORMING CONDITIONS-------------------- | DEAN | DEAN | | E= | C | 3423518 |
HOMEOWNER | ES | T | 08/02/2007 | PAID (REC#764894)NEED HOLD DOWN DEVICE FOR BACK FEED BREAKER. | DEAN | DEAN | | ES | T | 3423509 |
HOMEOWNER | E= | R | 07/30/2007 | SEE SERVICE, ALSO NEED STAMPED PLANS ON SITE AT NEXT INSPECTION. | DEAN | DEAN | | E= | R | 3423501 |
HOMEOWNER | ES | R | 07/30/2007 | NEED MAIN BREAKER FOR PANEL, NEED 1 GROUND ROD AND GROUNDING ELECTRODE CONDUCTOR TO GROUND BAR. | DEAN | DEAN | | ES | R | 3423495 |
HOMEOWNER | ER | C | 12/12/2006 | ----------------NEED MAIN FOR PANEL, CALL SERVICE INSPECTION WHEN READY-------------------- | DEAN | DEAN | | ER | C | 3423486 |
HOMEOWNER | H= | C | 09/25/2007 | | NANCY | NANCY | | H= | C | 3423593 |
HOMEOWNER | H= | R | 09/21/2007 | GAS LEAK IN ATTIC AT CSST AND GAS SHUT OFF FITTING. INSTALL A HANDLE ON PANEL IN BATHROOM. ALSO INSTALL SIGNAGE SHOWING THERE IS A GAS SHUT OFF BEHIND PANEL. | NANCY | NANCY | | H= | R | 3423585 |
HOMEOWNER | H= | R | 09/19/2007 | GAS LEAK WHERE CSST CONNECTS TO GAS COCK. | NANCY | NANCY | | H= | R | 3423579 |
HOMEOWNER | H= | P | 09/14/2007 | GAS SHUT OFF MUST BE LOCATED BEFORE FLEX CONNECTOR TO FURNACE. NOTE: TIF GAS LINE IN ATTIC AT NEXT INSPECTION. | NANCY | NANCY | | H= | P | 3423570 |
HOMEOWNER | HC | C | 08/21/2007 | OK TO SET THE METER. | JEFFB | JEFFB | | HC | C | 3423557 |
HOMEOWNER | HO | C | 08/21/2007 | 60 LB TEST IS OK. | JEFFB | JEFFB | | HO | C | 3423564 |
HOMEOWNER | HI | C | 04/06/2007 | 10 LB TEST OK. #19 CSST FROM OLD MANIFOLD IN WALL OF KITCHEN UP TO NEW ATTIC FURNACE. AT FINAL CHECK FOR ACCESS PANEL IN WALL. | NANCY | NANCY | | HI | C | 3423550 |
HOMEOWNER | HRR | C | 04/06/2007 | BY FINAL STRAP SUPPLY AIR DUCTS IN ATTIC. COMPLETELY INSULATE RETURN AIR IN ATTIC. AT FINAL CHECK FOR ACCESS DOOR TO GAS SHUT OFF IN WALL. ALSO WILL NEED CLARIFICATION ABOUT 2 LB SYSTEM FROM AQUILA. IS 2 LB SYSTEM BEING INSTALLED? IF SO, PRESSURE TEST REQUIRED AND WILL NEED PRESSURE REGULATOR INSTALLED. | NANCY | NANCY | | HRR | C | 3423542 |
HOMEOWNER | HRR | P | 04/04/2007 | HAVE CONTRACTOR ATTACH HIS PERMIT OR BE INCLUDED ON HOMEOWNER'S PERMIT FOR FURNACE INSTALLED IN ATTIC. WILL NEED PRESSURE TEST ON GAS LINE TO ATTIC FURNACE. REMOVE ALL SAGS AND KINKS ON FLEX DUCT. COMPLETELY INSULATE RETURN AIR IN ATTIC. | NANCY | NANCY | | HRR | P | 3423534 |
HOMEOWNER | HRR | T | 12/12/2006 | PAID (REC# 743899)NOT READY - FURN NOT VENTED, BATH EXHAUSTS NOT RUN, FIREPLACE VENT NOT IN, SOME DUCTS NOT COMPLETE, NO APPROVED PLANS, PERMIT DOESN'T SEEM TO REFLECT THAT THIS IS FINISHING A DETACHED GARAGE & INSPECTOR NEEDS TO RESEARCH IF EXISTING WAS PERMITED & INSPECTED, THIS IS A HOMEOWNER PERMIT SO HOMEOWNER NEEDS TO BE ON JOB AT INSPECTIONS INSTEAD OF HIRED APPARENTLY UNLICENSED WORKERS | DOUGR | DOUGR | | HRR | T | 3423526 |
HOMEOWNER | P= | C | 09/25/2007 | | SCOTT | SCOTT | | P= | C | 3423677 |
HOMEOWNER | P= | T | 09/21/2007 | PAID (REC#771750)SHOWER VALVES ARE NOW CROSSED AND OFF IS IN THE MIDDLE POSITION. NEED APPROVED DISHWASHER AIR-GAP. A REINSPECTION FEE IS REQUIRED. | SCOTT | SCOTT | | P= | T | 3423671 |
HOMEOWNER | P= | T | 09/19/2007 | PAID (REC#771252)DISHWASHER STILL NEEDS APPROVED AIR-GAP. NEED TO SET SHOWER LIMITS INSIDE THE SHOWER VALVE. | SCOTT | SCOTT | | P= | T | 3423664 |
HOMEOWNER | P= | R | 09/14/2007 | LEAK ON EAST LAV. BOTH SHOWER HEADS LEAK. SET SHOWER LIMITS. DISHWASHER NEEDS TO DRAIN THROUGH APPROVED AIR-GAP. | SCOTT | SCOTT | | P= | R | 3423656 |
HOMEOWNER | PTO | C | 08/28/2007 | | SCOTT | SCOTT | | PTO | C | 3423648 |
HOMEOWNER | PTO | R | 08/21/2007 | CONTINUATION OF NOTES FOR 8-21-07. NOTICED JOIST BELOW SHOWER HAS BEEN DAMAGED BY MODIFICATIONS TO PLUMBING; WILL NEED TO BE REINSPECTED. | SCOTT | SCOTT | | PTO | R | 3423641 |
HOMEOWNER | PTO | T | 08/21/2007 | PAID (REC#766633)ROUGH PLUMBING HAS NEVER PASSED INSPECTION. BUILDING IS NOW ROCKED. WORK IS BEING DONE BY UNLICENSED CONTRACTOR. 3 OF THE PREVIOUS 4 INSPECTIONS HAVE HAD LEAKS, BACKFALL, IMPROPERLY GLUED JOINTS, AND INCORRECT MATTERIALS. TODAY THE SYSTEM WAS NOT ON TEST. REPAIRS TO THE SYSTEM WERE ATTEMPTED WITH A TORCH , OR SOME FORM OF FIRE, TO STOP LEAKS. REMOVE AND REPLACE THAT AREA. WATER WAS ADDED DURING THE INSPECTION, RESULTING IN A LEAK IN THE UPPER WALL, NEAR T | SCOTT | SCOTT | | PTO | T | 3423633 |
HOMEOWNER | PTO | L | 08/15/2007 | LOCKED AT 1:45. CHECKED ALL DOORS. | SCOTT | SCOTT | | PTO | L | 3423625 |
HOMEOWNER | PTO | T | 08/02/2007 | PAID (REC#765501)THE PLUMBING HAS NEVER BEEN COMPLETED, AND NOW HAS BEEN SHEETROCKED. WATER IS LEAKING OUT OF THE CEILING, WHERE BACKFALL ISSUES CAUSED A TRIP-FEE ON LAST INSPECTION. AN ABS CLOSET FLANGE HAS BEEN GLUED ONTO PVC SINCE THE LAST INSPECTION. LAST INSPECTION, THE BACKFLL WAS MARKED, AND NOW BECAUSE OF CHANGES THERE ARE 2 AREAS OF BCKFALL IN THAT AREA. THE WEST SIDE PROBLEMS HAVE BEEN COVERED BY DRYWALL. | SCOTT | SCOTT | | PTO | T | 3423617 |
HOMEOWNER | PTO | T | 04/04/2007 | PAID (REC#745047)STILL NEED SHOWER 3-PIECE TILE DRAINS. REPAIRS HAVE CAUSED NEW BACKGRADE IN 2 MARKED AREAS ON LOWER LEVEL. | SCOTT | SCOTT | | PTO | T | 3423609 |
HOMEOWNER | PTO | R | 12/12/2006 | 3'' TO WASHER HAS BACKGRADE AND NEEDS SUPPORT BELOW. STANDPIPE FOR WASHER EXCEEDS 30''. BRING WATER LINES FOR WASHER TO FRONT OF WALL. SUPPORT DWV ESPECIALLY IN ATTIC AT 4'. INSTALL SHOWER PANS OR TILE FITTINGS. COMPLETE NAIL PROTECTION. SCREWS FOR TOILETS AND SHOWERS NEED TO BE PLATED. WEST SHOWER IS "S" TRAPPED. WHERE IS ALL PLUMBING GOING TO DRAIN TO? STRAP PEX AT 32''. | SCOTT | SCOTT | | PTO | R | 3423601 |