SKYLINE CONSTRUCTION SERVICES | BFR | C | 01/16/2007 | | BLAKE | BLAKE | | BFR | C | 3441651 |
SKYLINE CONSTRUCTION SERVICES | B= | C | 01/16/2007 | OK PENDING OTHER FINAL INSPECTIONS | BLAKE | BLAKE | | B= | C | 3441644 |
SKYLINE CONSTRUCTION SERVICES | BFR | P | 12/18/2006 | WALLS OK | DALE | DALE | | BFR | P | 3441636 |
LARRY MIXON ELECTRICAL CONTR. | E= | C | 01/12/2007 | | GARY | GARY | | E= | C | 3441698 |
LARRY MIXON ELECTRICAL CONTR. | ES | C | 01/12/2007 | COMMERCIAL SERVICE: EXISTING SERVICE | GARY | GARY | | ES | C | 3441690 |
LARRY MIXON ELECTRICAL CONTR. | ER | P | 01/10/2007 | CEILINGS | GARY | GARY | | ER | P | 3441681 |
LARRY MIXON ELECTRICAL CONTR. | ER | P | 01/08/2007 | ABOVE DROP CEILING | GARY | GARY | | ER | P | 3441674 |
LARRY MIXON ELECTRICAL CONTR. | ER | P | 12/15/2006 | WALLS ONLY | GARY | GARY | | ER | P | 3441667 |
LARRY MIXON ELECTRICAL CONTR. | E= | R | 12/14/2006 | NOT READY | GARY | GARY | | E= | R | 3441660 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 01/16/2007 | RECEIVED BALANCE REPORT FROM PEAK HEATING AND AIR CONDITIONING, INC. | LYNNS | LYNNS | | H= | C | 3441629 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 01/12/2007 | HVAC FINAL PENDING BALANCE REPORT. | LYNNS | LYNNS | | H= | P | 3441621 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | C | 01/04/2007 | ROUGH DUCT COMPLETE. | LYNNS | LYNNS | | HD | C | 3441613 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 12/22/2006 | NEW AIR HANDLER INSTALLED WITH ROUND PIPE AND SEALED NO DROPS YET | JACK | JACK | | HD | P | 3441605 |
TRI-LAKES PLUMBING, LLC | P= | C | 01/12/2007 | | LEE | LEE | | P= | C | 3441745 |
TRI-LAKES PLUMBING, LLC | P= | R | 01/11/2007 | NEED AIR GAP AT T&P DRIP LEG AT DRAIN PAN, RAISE WATER HEATER IF DRAIN PAN USED FOR INDERECT WASTE FOR T&P(SO WATER HEATER DOESN'T SIT IN WATER), PLANS CALL FOR 10 GALLON RHEEM(HAS USED 6 GALLON STATE), PLANS CALL FOR THERMAL EXPANSION TANK | JEFF | JEFF | | P= | R | 3441736 |
TRI-LAKES PLUMBING, LLC | PTO | C | 12/22/2006 | | LEE | LEE | | PTO | C | 3441729 |
TRI-LAKES PLUMBING, LLC | PTO | T | 12/19/2006 | PAID (REC#729933) NOT READY AT 9:20, CAME BACK AT 11:20, STILL NOT READY, THIS IS THE FOURTH TRIP | LEE | LEE | | PTO | T | 3441721 |
TRI-LAKES PLUMBING, LLC | PTO | R | 12/18/2006 | STILL WORKING ON WATER PIPE, FLOOR DRAINS NOT VENTED TO CODE, LACKS ALL RISER CLAMPS, STILL NEED JOB DISCRIPTION UPDATED | LEE | LEE | | PTO | R | 3441713 |
TRI-LAKES PLUMBING, LLC | PTO | R | 12/15/2006 | WAIVED TRIP FEE--THIS TIME----PAID (REC#729552)NEXT TO MACYS---UPPER LEVEL---NOT READY--1) ISOLATE PVC PLASTIC FROM METAL STUDS 2) NAIL PROTECT PVC 3) NAIL PROTECT COPPER LINES 4) WATER HEATER PAN DRAIN IS UNDER SIZED WITH T-P DRAIN INTO PAN 5) DRINKING FOUNTAIN HAS HOT WATER PIPED TO IT---GET PERMIT CORRECTED BY NEXT INSPECTION--TO MANY FIXTURE--NOT ENOUGH WORK | LYNNIE | LYNNIE | | PTO | R | 3441705 |