GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | C | 05/20/2008 | ELEVATOR INSPECTOR, JOHN W IS UNABLE ENTER V= DUE TO PROBLEM IN THE PROGRAM, BUT SAYS THE ELEVATOR IS COMPLETE AND MAY BE PUT INTO SEVICE | RICK | RICK | | B= | C | 3678878 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | B= | P | 04/08/2008 | NEED ELEVATOR FINAL | RICK | RICK | | B= | P | 3481276 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | C | 02/15/2008 | LETTER FROM MLA ENGINEERING FOR XRAYING THE STEEL FOR THE BOND BEAMS, TESTS ARE FOR THE TOP PORTION OF THE TOWER, TARRACON HAD SURVEYED BOTTOM OF TOWER, COPY OF TARRACON REINFORCEING INSPECTION ON FILE AS WELL. | ED | ED | | BFN | C | 3481268 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BSP | P | 10/03/2007 | RAFTER FRAMING OK
| MIKE | MIKE | | BSP | P | 3481260 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFR | R | 10/03/2007 | NEED COMPLETED FOUNDATION INSPECTION/DRAIN INSPECTION/BOND BEAM INSPECTION,NEED ELCTRIC INSPECTION & STRUCTURAL STEEL INSPECTION REPORT
| MIKE | MIKE | | BFR | R | 3481252 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | R | 09/28/2007 | Need approved plans,No additional foundation work completed | MIKE | MIKE | | BFN | R | 3481244 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFN | P | 08/27/2007 | COLUMN POSTS - COLUMN BOLTS MUST BE INSIDE REBAR TIES
| MIKE | MIKE | | BFN | P | 3481236 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | C | 08/27/2007 | | MIKE | MIKE | | BFT | C | 3481226 |
GE JOHNSON CONSTRUCTION COMPANY, INC. | BFT | P | 08/16/2007 | ELEVATOR PAD OK
| MIKE | MIKE | | BFT | P | 3481163 |
WEST ELECTRIC GROUP, INC. | E= | C | 03/05/2008 | INSTALLED DISCONNECTS IN ELEV ROOM FOR BRANCH CIRCUITS TO TOWER AND IDENTIFIED SERVICE DISCONNECT 1 THRU 4. | DEAN | DEAN | | E= | C | 3481352 |
WEST ELECTRIC GROUP, INC. | E= | R | 03/03/2008 | AFTER DISCUSSION WITH ENGINEER, WE ARE ALLOWING THE INSTALLATION OF 5 INDIVIDUAL SWITCHES INSTALLED NEXT TO THE 480-VOLT DISCONNECT WITH IDENTIFICATION FOR ALL 6 HANDLES AS SERVICE DISCONNECT 1 OF 6, 2 OF 6 ETC. | DEAN | DEAN | | E= | R | 3481345 |
WISE ELECTRIC, INC. | ER | P | 10/01/2007 | exterior rough | BRET | BRET | | ER | P | 3481300 |
THYSSENKRUPP ELEVATOR CORPORATION | HE= | C | 05/21/2008 | | JOHNW | JOHNW | | HE= | C | 3679145 |
HVAC SOLUTIONS, INC. | H= | C | 05/19/2008 | HAS TRANSFERS IN OUTSIDE DOOR AND HAS APPROVED M-SHEET. | JON | JON | | H= | C | 3678323 |
HVAC SOLUTIONS, INC. | HV | P | 05/13/2008 | CALLED CONTRACTOR.. NEED CALL AHEAD FOR ACCESS AND TO ENSURE NEW APPROVED M-SHEET IS AVAILABLE FOR INSPECTION, TO CHECK TYPE AND SIZING OF GRILLS FOR ELEVATOR EQUIPMENT ROOM. VERIFIED THROUGH RUSS THAT M-SHEET WAS SUBMITTED. NO EVIDENCE IN PLAN TRACKING OF REVIEW. | JON | JON | | HV | P | 3675169 |
HVAC SOLUTIONS, INC. | H= | P | 02/20/2008 | changed status because of no m-sheet for elevator equipment room and no ventilation. must see russ kauk in plan review with approved m-sheet and call new inspection.. contacted rich and left message with myron over this issue. | JON | JON | | H= | P | 3481315 |
THYSSENKRUPP ELEVATOR CORPORATION | V= | P | 04/11/2008 | 3--08--MISSING DOOR CLOSURE AND PHONE --4-10--NEED MECH ROOM VENT FOR EQUIPMENT--SEE PERMIT G18708 | JOHNW | JOHNW | | V= | P | 3481308 |