CREEKSTONE DEVELOPMENT, INC. | B= | C | 11/30/2007 | ITEMS CORRECTED. | NATHAN | NATHAN | | B= | C | 3550731 |
CREEKSTONE DEVELOPMENT, INC. | B= | R | 11/21/2007 | FULLY FINISHED BASEMENT/ATTIC INSULATION NOT DEEP ENOUGH,,NO RULERS ???/ANCHOR EGRESS LADDER,S/SMOKE DETECTORS NOT WORKING CORRECTLY | FRANK | FRANK | | B= | R | 3550725 |
CREEKSTONE DEVELOPMENT, INC. | BLA | C | 09/18/2007 | | ED | ED | | BLA | C | 3550718 |
CREEKSTONE DEVELOPMENT, INC. | BFR | C | 09/12/2007 | | TODDS | TODDS | | BFR | C | 3550711 |
CREEKSTONE DEVELOPMENT, INC. | BIN | C | 09/12/2007 | | TODDS | TODDS | | BIN | C | 3550702 |
CREEKSTONE DEVELOPMENT, INC. | BFR | P | 09/10/2007 | NEED A-35 @ TOP PLATE RT. SIDE OF 16' DOOR / MISSING HANGER @ (J1) MONO TRUSS ABOVE 16' DOOR / DROP 5" UNDER ALL PLUMBING AND H-VAC FOR INSULATION / PLAN CALLS (2) KING STUDS @ 5' WINDOW IN BED #2 / O.K. TO INSULATE | JEREMY | JEREMY | | BFR | P | 3550696 |
CREEKSTONE DEVELOPMENT, INC. | BSP | P | 09/05/2007 | OK TO COVER FRONT PORCH | ED | ED | | BSP | P | 3550688 |
CREEKSTONE DEVELOPMENT, INC. | BFD | C | 06/25/2007 | | BOBB | BOBB | | BFD | C | 3550675 |
CREEKSTONE DEVELOPMENT, INC. | BFN | C | 06/18/2007 | UFER GROUND OK, FOUNDATION AND SOILS ON FILE VERTS @ 4' AS PER DESIGN INSTALLED | ED | ED | | BFN | C | 3550669 |
CREEKSTONE DEVELOPMENT, INC. | BFT | C | 06/15/2007 | 2000 PSF, 2 INTERIOR PADS OK | ED | ED | | BFT | C | 3550659 |
SANCHEZ ELECTRIC, INC. | E= | C | 11/05/2007 | A/C INSTALLED | TIMA | TIMA | | E= | C | 3550842 |
SANCHEZ ELECTRIC, INC. | ER | C | 08/30/2007 | FINISHED BASEMENT | MATTHEW | MATTHEW | | ER | C | 3550834 |
SANCHEZ ELECTRIC, INC. | ES | C | 08/29/2007 | RESIDENTIAL UNDERGROUND: 200 AMP 3/W BY SANCHEZ ELEC: NEW RES | MATTHEW | MATTHEW | | ES | C | 3550828 |
SANCHEZ ELECTRIC, INC. | ER | T | 08/29/2007 | PAID (REC#767920)OVER ON OUTLET SPACING BOTH SIDES OF FIRE PLACE AND KITCHEN COUNTER, ADD OUTLETS TO CODE UPSTAIRS AND BASEMENT, MAKE UP SMOKE IN BASEMENT BEDROOM, INSTALL ROMEX CONNECTORS IN EX-FANS, MISSING BATH OUTLET, NEED NAIL PLATE IN FRONT HALL CEILING WHERE DRILLED THROUGH PRE-LAM ------ COMPLETE REINSPECT ----- | MATTHEW | MATTHEW | | ER | T | 3550817 |
SUMMIT COMFORT SYSTEMS, INC | H= | C | 11/08/2007 | FINISHED BASEMENT WITH A/C. HIGH/LOW COMBUSTION GRILLS TO MECH ROOM. | TOMS | TOMS | | H= | C | 3550859 |
SUMMIT COMFORT SYSTEMS, INC | H= | P | 11/05/2007 | NEED COMBUSTION AIR FOR WATER HEATER. NEED TO TERMINATE CONCENTRIC VENT PER MANUFACTURER'S INSTRUCTIONS. RBD NOTE; FINISHED BASEMENT, HAS A/C. | DICK | DICK | | H= | P | 3550853 |
AIRCO MECHANICAL, INC. | HC | C | 09/10/2007 | RELEASE METER. | TOMS | TOMS | | HC | C | 3550769 |
AIRCO MECHANICAL, INC. | HRR | C | 09/10/2007 | FINISHED BASEMENT WITH A/C ROUGH. | TOMS | TOMS | | HRR | C | 3550761 |
AIRCO MECHANICAL, INC. | HRR | P | 09/07/2007 | WAIVED TRIP FEE. LINESET WAS STOLEN FOR A/C IN FINISHED BASEMENT. | TOMS | TOMS | | HRR | P | 3550754 |
AIRCO MECHANICAL, INC. | HRR | P | 09/06/2007 | WOOD HEADER IS TO BE COMPLETELY ABOVE FIREPLACE STAND OFFS. REST OK. | JON | JON | | HRR | P | 3550747 |
AIRCO MECHANICAL, INC. | HRR | R | 09/04/2007 | POWDER BATH FAN VENT FULL OF WATER IN GARAGE, FIREPLACE FRAMING BELOW TOP STAND OFFS, NEED BATH EXHAUST FAN OVER TUB/SHOWER AERA IN MASTER BATH, NOTE: FINISHED BASEMENT, A/C COIL INSTALLED ONLY | TED | TED | | HRR | R | 3550741 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 08/14/2007 | 1" FURNACE, WATER HEATER, 1 FIREPLACE. | DICK | DICK | | HI | C | 3550777 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 10/19/2007 | | MICK | MICK | | P= | C | 3550808 |
SPRINGS CUSTOM PLUMBING, INC. | P= | P | 10/18/2007 | NO WATER AT KITCHEN SINK. VACUUM BREAKER OK. | MICK | MICK | | P= | P | 3550801 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 08/14/2007 | NO PERMIT. | MARTY | MARTY | | PTO | C | 3550793 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 06/28/2007 | | MICK | MICK | | PB | C | 3550785 |