SERVICETEK CONSTRUCTION & MAINTENANCE CONTRACTORS, INC. | B= | C | 02/12/2008 | | BOBB | BOBB | | B= | C | 3647639 |
SERVICETEK CONSTRUCTION & MAINTENANCE CONTRACTORS, INC. | BFR | C | 02/01/2008 | | BOBB | BOBB | | BFR | C | 3647635 |
SERVICETEK CONSTRUCTION & MAINTENANCE CONTRACTORS, INC. | B= | P | 02/01/2008 | Final inspection ok with mechanical final inspection. | BOBB | BOBB | | B= | P | 3647626 |
HEATING & PLUMBING ENGINEERS, INC | BSP | T | 01/15/2008 | PAID (REC#788098)ADDITIONAL PLAN REVIEW TIME: $50.000 From: TCRIPPEN see new splice page | TCRIPPEN | TCRIPPEN | | BSP | T | 3647537 |
SERVICETEK CONSTRUCTION & MAINTENANCE CONTRACTORS, INC. | BFR | P | 01/14/2008 | Walls ok with other rough inspections. | BOBB | BOBB | | BFR | P | 3647620 |
BIBLE ELECTRIC, INC. | E= | C | 01/28/2008 | | MATTHEW | MATTHEW | | E= | C | 3647614 |
BIBLE ELECTRIC, INC. | ER | C | 01/28/2008 | | MATTHEW | MATTHEW | | ER | C | 3647608 |
BIBLE ELECTRIC, INC. | ER | P | 01/10/2008 | WALLS OK | MATTHEW | MATTHEW | | ER | P | 3647602 |
HEATING & PLUMBING ENGINEERS, INC | H= | C | 02/11/2008 | RECIEVED BALANCE REPORT. | JON | JON | | H= | C | 3647596 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 02/05/2008 | CALLED ANNMARIE AT HPE AND LET HER KNOW THAT THE BALANCE REPORT DID NOT SHOW OUTSIDE PER NEW M-SHEET SPLICE. NEED NEW BALANCE REPORT WITH OSA SHOWN. REST OK. | JON | JON | | H= | P | 3647588 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 02/01/2008 | JUST NEED BALANCE REPORT FAX OR E-MAIL REST OK. | JON | JON | | H= | P | 3647581 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 01/24/2008 | NEED BALANCE REPORT WITH OSA SHOWN. REST OK. | JON | JON | | H= | P | 3647574 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 01/16/2008 | NEED BALANCE REPORT WITH OSA SHOWN. NEED TRANSFER OPENING FROM ADJOINING VACANT SPACE PER PLAN ABOVE CEILING. RBD NOTE: WHEN ADJOINING SPACE IS LATTER OCCUPIED RTU WILL HAVE TO BE DEDICATED TO THIS 1646 SPACE AT THAT TIME. | JON | JON | | H= | P | 3647567 |
HEATING & PLUMBING ENGINEERS, INC | HD | C | 01/16/2008 | | JON | JON | | HD | C | 3647560 |
HEATING & PLUMBING ENGINEERS, INC | H= | R | 01/11/2008 | WENT OVER THIS INSPECTION OVER THE PHONE WITH BILL GANYARD NO SITE VISIT NEEDED.. PLEASE SEE NOTES FROM 1-10-08 INSPECTION. | JON | JON | | H= | R | 3647551 |
HEATING & PLUMBING ENGINEERS, INC | HD | R | 01/10/2008 | MECHANICAL PLANS DO NOT SHOW SCOPE OF WORK, HAS MECHANICAL DEMO WHICH IS NOT SHOWN. HAS SUPPLY AIR FROM ADJOINING SPACE SUPPLYING AIR TO THIS SPACE WITH NO RETURN AIR SHOWN.. ARCHITECTURAL SHEETS SHOW NEW ROOMS AND WALLS. NOT SHOWN ON MECHANICAL. ALSO NEED TO ENSURE THERE IS NO RATING ON ANY WALLS AS PLANS DO HAVE SOME CONFLICTS FOR TYPE OF CONSTRUCTION. DID NOT SEE ANY VENTILATION RATES ON APPROVED PLANS. NEED PROPER APPROVED MECHANICAL SHEETS APPROVED BY RBD. | JON | JON | | HD | R | 3647544 |