NEW GENERATION HOMES, INC | B= | C | 06/30/2008 | NO A/C, WATER METER IS IN, UNFINISHED BASEMENT, DECK AND PORCH OK. | NATHAN | NATHAN | | B= | C | 3700721 |
NEW GENERATION HOMES, INC | BSP | P | 05/08/2008 | front deck frame ok | NATHAN | NATHAN | | BSP | P | 3672818 |
NEW GENERATION HOMES, INC | BSP | P | 05/08/2008 | front porch and deck posts ok. | NATHAN | NATHAN | | BSP | P | 3672816 |
NEW GENERATION HOMES, INC | BSP | P | 05/05/2008 | (5) DECK PIERS AND DECK FRAMING OK | ED | ED | | BSP | P | 3670879 |
NEW GENERATION HOMES, INC | BIN | C | 04/29/2008 | | ED | ED | | BIN | C | 3667951 |
NEW GENERATION HOMES, INC | BFR | C | 04/25/2008 | RECHECK DRAFTSTOP AT INSULATION, SOME ARES MISSING | ED | ED | | BFR | C | 3647572 |
NEW GENERATION HOMES, INC | BFR | R | 04/23/2008 | BLOCK EAST END GARAGE DOOR BRACKET/STRAP PLATE AT GARAGE TO HOUSE DOOR/ SHIM GARAGE DOOR TRIMMERS AND WINDOWS AT ENTRY, LOFT AND MICROLAM AT HALL/ STRAP STAIR WALL PLATE AT NOTCH FROM PLUMBING/ STRAP ALL 5 STUD POSTS KITCHEN AND BASEMENT/ A-35 AT EACH END OF ENTRY WALL AND MASTER BATH POP OUT/ ANCHOR BOLTS AT PLATE BREAKS IN BASEMENT/ NEED MECHANICAL CONNECTION AT STAIR POST TO LVL/ CUT JOIST OVER B VENT AT BASEMENT. DO NOT INSULATE. | NATHAN | NATHAN | | BFR | R | 3647578 |
NEW GENERATION HOMES, INC | BSP | P | 04/01/2008 | front porch clips and exterior shear t-ply ok | ED | ED | | BSP | P | 3647605 |
NEW GENERATION HOMES, INC | BFI | C | 03/18/2008 | | NATHAN | NATHAN | | BFI | C | 3647601 |
NEW GENERATION HOMES, INC | BFD | C | 03/18/2008 | DRAIN ENTIRE TO STREET/ INTERIOR FLOAT 1.5"/ FINAL GRADE 5%/ SOILS PICKED UP. | NATHAN | NATHAN | | BFD | C | 3647595 |
NEW GENERATION HOMES, INC | BFN | C | 03/06/2008 | design on file / euffer rod in / need soils at drain | TODDS | TODDS | | BFN | C | 3647589 |
NEW GENERATION HOMES, INC | BFT | C | 02/29/2008 | 2000,PSWF, (4) INTERIOR PASD | ED | ED | | BFT | C | 3647583 |
MOUNTAIN STATES ELECTRIC | E= | C | 06/05/2008 | | MIKEC | MIKEC | | E= | C | 3687206 |
MOUNTAIN STATES ELECTRIC | EUG | C | 04/23/2008 | OK TO BACKFILL | MATTHEW | MATTHEW | | EUG | C | 3647556 |
MOUNTAIN STATES ELECTRIC | ES | C | 04/22/2008 | RESIDENTIAL UNDERGROUND: 150 AMP 3/W BY MOUNTAIN STATES: METER SET | MATTHEW | MATTHEW | | ES | C | 3647559 |
MOUNTAIN STATES ELECTRIC | ER | C | 04/21/2008 | UNFINISHED BASEMENT | MATTHEW | MATTHEW | | ER | C | 3647565 |
PRECISION HEATING & AIR COND. | H= | C | 06/23/2008 | Unfinished basement. AC complete. | MICK | MICK | | H= | C | 3696624 |
PRECISION HEATING & AIR COND. | HC | C | 04/22/2008 | OK FOR METER. | DICK | DICK | | HC | C | 3647627 |
PRECISION HEATING & AIR COND. | HRR | C | 04/22/2008 | WATER HEATER AND WATER HEATER VENT CONNECTOR AT FINAL. UNFINISHED BASEMENT, HAS OUTSIDE AIR DUCTED TO FURNACE RETURN AIR, NO A/C. | DICK | DICK | | HRR | C | 3647636 |
PRECISION HEATING & AIR COND. | HRR | R | 04/21/2008 | RANDY CANCELLED | JOEL | JOEL | | HRR | R | 3647640 |
JOHNSON HEATING AND PLUMBING, INC. | HI | C | 04/17/2008 | 1" FURNACE, WATER HEATER, 1 FIREPLACE. | DICK | DICK | | HI | C | 3647611 |
JOHNSON HEATING AND PLUMBING, INC. | P= | C | 06/23/2008 | No sprinkler. Basement bath stubbed in. | MICK | MICK | | P= | C | 3696632 |
JOHNSON HEATING AND PLUMBING, INC. | PTO | C | 04/17/2008 | NO SPRINKLER STUB. UNFINISHED BASEMENT. | DICK | DICK | | PTO | C | 3647621 |
JOHNSON HEATING AND PLUMBING, INC. | PB | C | 03/21/2008 | | MICK | MICK | | PB | C | 3647616 |