COLARELLI CONSTRUCTION, INC. | B= | C | 12/12/2008 | | DALE | DALE | | B= | C | 3781449 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 06/26/2008 | 4th floor all soffitts ok | DALE | DALE | | BFR | P | 3698972 |
COLARELLI CONSTRUCTION, INC. | BSP | P | 06/11/2008 | 4th floor soffitts and ceilings ok pending other inspections | DALE | DALE | | BSP | P | 3690188 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 06/04/2008 | 4th floor walls ok pending other inspections | DALE | DALE | | BFR | P | 3686435 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 05/29/2008 | frame around ducts 4th floor ok | DALE | DALE | | BFR | P | 3683392 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 05/28/2008 | ceiling and soffitts ok at 3rd floor pending other inspections | DALE | DALE | | BFR | P | 3682541 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 05/20/2008 | 3rd floor walls ok pending other inspections | DALE | DALE | | BFR | P | 3678820 |
COLARELLI CONSTRUCTION, INC. | BSP | P | 05/09/2008 | walk-thru with contractor | DALE | DALE | | BSP | P | 3673968 |
KENNY ELECTRIC SERVICE, INC. | E= | C | 09/22/2008 | | DEAN | DEAN | | E= | C | 3744156 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 09/02/2008 | NEED FURNITURE SYSTEMS INSTALLED ON 3RD AND 4TH FLOOR FOR FINAL | BRET | BRET | | E= | P | 3734081 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 08/15/2008 | could not make contact with electrician | MIKEC | MIKEC | | E= | P | 3726475 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 08/11/2008 | ALL 4TH FLOOR OK EXCEPT OUTSIDE NORTH AND SOUTH CONFRENCE ROOMS----------------CHECK STORAGE ROOM 417 FOR KO SEAL AND STRAP M/C----------- | DEAN | DEAN | | E= | P | 3723239 |
KENNY ELECTRIC SERVICE, INC. | E= | P | 07/25/2008 | ALL 3RD FLOOR OK EXCEPT MENS BATHROOM GFCI AND GFCI RIGHT OF BREAKER ROOM SINK. | DEAN | DEAN | | E= | P | 3714358 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/23/2008 | REMAINING 3RD FLOOR CEILINGS OK. | DEAN | DEAN | | ER | P | 3713197 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/22/2008 | CEILINGS 4TH FLOOR AS MARKED ON PLANS. | DEAN | DEAN | | ER | P | 3711947 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/21/2008 | 4TH FLOOR DROP CEILING AS HIGHLIGHTED ON SHEET E3.2 ON APPROVED SET | JOSEPH | JOSEPH | | ER | P | 3711656 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/17/2008 | 4TH FLOOR CEILINGS AS MARKED ON PLAN E3.2. | DEAN | DEAN | | ER | P | 3709465 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/16/2008 | 3RD FLOOR CEILINGS AS MARKED ON PLAN E3.1. | DEAN | DEAN | | ER | P | 3708782 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/15/2008 | WALLS OF 4TH FLOOR NORTH CONFRENCE ROOMS OK AND CEILINGS OF 3RD FLOOR AS MARKED ON PLAN E3.1 | DEAN | DEAN | | ER | P | 3707989 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/10/2008 | ALL 3RD FLOOR OFFICE CEILINGS OK. STILL HAVE ALL THE LARGE OPEN AREAS ON 3RD TO INSPECT. 4TH FLOOR OFFICE CEILINGS AS MARKED ON PLANS. | DEAN | DEAN | | ER | P | 3705663 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/08/2008 | 4TH FLOOR WALLS AND SOFFIT IN NORTH ROOM 439. | DEAN | DEAN | | ER | P | 3704004 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 07/02/2008 | 4TH FLOOR SOUTH CONFRENCE ROOM WALLS AND SOFFITS OK. | DEAN | DEAN | | ER | P | 3701899 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 06/27/2008 | ALL 3RD FLOOR INTERIOR OFFICE CEILINGS OK EXCEPT FAR EAST CENTER OFFICE. | DEAN | DEAN | | ER | P | 3699480 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 06/11/2008 | 4TH FLOOR BATHROOM HARD CEILINGS OK. | DEAN | DEAN | | ER | P | 3690199 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 06/09/2008 | 3RD FLOOR BATHROOM LIDS AND 4TH FLOOR BREAK ROOM LID OK. SAME AS F.A. THIS DATE. | DEAN | DEAN | | ER | P | 3688667 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 06/03/2008 | 4th-floor-wall-excluding-conf-rooms-but-icluding-fire-stubs | ARNOLD | ARNOLD | | ER | P | 3686235 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 05/22/2008 | REMAINING 3RD FLOOR WALLS OK, 3RD FLOOR HARD LID IN BREAK ROOM OK, 4TH FLOOR EXTERIOR WALLS OK EXCEPT FOR THE AREAS THAT POP OUT ON NORTH AND SOUTH SIDE. | DEAN | DEAN | | ER | P | 3680212 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 05/19/2008 | ALL 3RD FLOOR INTERIOR WALLS EXCEPT FOR ROOMS 339,341, AND 343. | DEAN | DEAN | | ER | P | 3678301 |
KENNY ELECTRIC SERVICE, INC. | ER | P | 05/09/2008 | 3RD FLOOR EXTERIOR WALLS AS MARKED ON APPROVED PLANS. | DEAN | DEAN | | ER | P | 3673621 |
HVAC SOLUTIONS, INC. | H= | C | 10/29/2008 | RECEIVED BALANCE REPORT. SENT TO SCANNING. | LYNNS | LYNNS | | H= | C | 3762284 |
HVAC SOLUTIONS, INC. | H= | P | 07/24/2008 | HVAC FINAL PENDING BALANCE REPORT. | LYNNS | LYNNS | | H= | P | 3713743 |
HVAC SOLUTIONS, INC. | H= | P | 07/22/2008 | PARTIAL FINAL FOR 4TH FLOOR. NEED TO SEE PERIMETER REGISTERS, LINEAR REGISTERS IN HARD SOFFITS AND BATH ROOMS. BALANCE REPORT FOR ALL. | LYNNS | LYNNS | | H= | P | 3712171 |
HVAC SOLUTIONS, INC. | H= | P | 07/21/2008 | 3RD FLOOR OK FOR TILE. | LYNNS | LYNNS | | H= | P | 3711451 |
HVAC SOLUTIONS, INC. | HD | P | 07/03/2008 | 4TH FLOOR NORTH EAST, DOWN STREAM OF VAV'S: ROUGH DUCT OK. OK TO INSULATE. 3RD AND 4TH FLOOR VAV TIE INS TO MAINS: DUCT OK. OK TO INSULATE. | NANCY | NANCY | | HD | P | 3702828 |
HVAC SOLUTIONS, INC. | HD | P | 06/30/2008 | ROUGH DUCT ON VAV'S IN NORTH WEST CORNER OF 4TH FLOOR OK TO INSULATE. | LYNNS | LYNNS | | HD | P | 3700637 |
HVAC SOLUTIONS, INC. | HD | P | 06/26/2008 | INSPECTION OF 4TH FLOOR, SOUTHWEST END, DUCTWORK DOWN STREAM OF VAV BOXES. ALL DUCTS AND LATERALS OK. OK TO INSULATE. | NANCY | NANCY | | HD | P | 3698830 |
HVAC SOLUTIONS, INC. | HD | P | 06/24/2008 | ROUGH DUCT ON 4TH FLOOR FOR MAIN LINE AND SOUTH EAST VAV'S. OK TO INSULATE. | LYNNS | LYNNS | | HD | P | 3697472 |
HVAC SOLUTIONS, INC. | HD | P | 06/23/2008 | NEED TO ADD CLIPS TO ALL JOINTS, HANG RADIUS THROAT/HEEL ELBOWS. | LYNNS | LYNNS | | HD | P | 3696527 |
HVAC SOLUTIONS, INC. | HD | P | 06/19/2008 | rough duct on low pressure duct on 3rd floor, ok to insulate. need to see connections to vav's. | LYNNS | LYNNS | | HD | P | 3695100 |
HVAC SOLUTIONS, INC. | HD | P | 06/12/2008 | ROUGH DUCT ON MEDIUM PRESSURE DUCT ON 3RD FLOOR OK. | LYNNS | LYNNS | | HD | P | 3691176 |
HVAC SOLUTIONS, INC. | HD | P | 06/09/2008 | ROUGH DU8CT ON 4TH FLOOR, BATH ROOMS, BREAK ROOM AND ELEVATOR LOBBY, OK TO COVER. | LYNNS | LYNNS | | HD | P | 3688904 |
HVAC SOLUTIONS, INC. | HD | P | 06/03/2008 | ROUGH DUCT ABOVE HARD LIDS IN BATH ROOMS AND BREAK ROOM OK TO COVER. | LYNNS | LYNNS | | HD | P | 3686144 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 09/02/2008 | PERMIT CARD HAS BEEN MISPLACED | LEE | LEE | | P= | C | 3734191 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 08/11/2008 | 2ND FLOOR MENS RESTROOM, BREAK SINKS AND MOP SINKS OK PENDING HOT WATER REQUIREMENTS ARE MET, NEED PARTITIONS 3RD FLOOR MENS RESTROOMS AND ALL OF WOMENS RESTROOMS 2ND AND 3RD FLOORS | LEE | LEE | | P= | P | 3722940 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | C | 05/30/2008 |
| LEE | LEE | | PTO | C | 3684355 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 05/28/2008 | LEAKS ON DWV 4TH FLOOR RESTROOM | LEE | LEE | | PTO | P | 3682425 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 05/21/2008 | 3RD FLOOR RESTROOMS DWV & H20 WALLS AND CEILING ONLY, NOTE: STILL NEED DWV BELOW 3RD FLOOR IN 2ND FLOOR CEILING | LEE | LEE | | PTO | P | 3679621 |