E.G.C. SERVICES, INC | B= | C | 08/15/2008 | Balance report received 8/15/08 | OWEN | OWEN | | B= | C | 3725717 |
E.G.C. SERVICES, INC | B= | P | 08/14/2008 | NEED MECHANICAL FINAL | JOHNP | JOHNP | | B= | P | 3725609 |
E.G.C. SERVICES, INC | B= | R | 08/12/2008 | SHELL FINAL; FIRE FINAL; MECHANICAL FINAL; OCCUPANCY LOAD SIGN | JOHNP | JOHNP | | B= | R | 3723989 |
E.G.C. SERVICES, INC | BSP | T | 08/04/2008 | PAID (REC#819725) ADDITIONAL PLAN REVIEW TIME: $50 From: DALEH splice for change to duct layout | DALEH | DALEH | | BSP | T | 3719355 |
E.G.C. SERVICES, INC | BSP | T | 08/04/2008 | PAID (REC#819726) ADDITIONAL PLAN REVIEW TIME: $50 From: SHELBY three pages rtu cange of feeder and overcurrent protection | SHELBY | SHELBY | | BSP | T | 3719240 |
R D PLUMBING LLC | BSP | T | 08/04/2008 | PAID (REC#819727) ADDITIONAL PLAN REVIEW TIME: $50 From: TCRIPPEN new splice pages | TCRIPPEN | TCRIPPEN | | BSP | T | 3719199 |
E.G.C. SERVICES, INC | BSP | P | 07/28/2008 | DEMISING WALLS OK | JOHNP | JOHNP | | BSP | P | 3715458 |
E.G.C. SERVICES, INC | BFR | P | 07/14/2008 | WALLS OK | JOHNP | JOHNP | | BFR | P | 3707662 |
E.G.C. SERVICES, INC | BFR | P | 07/02/2008 | WALLS, EXCEPT NORTH WEST CORNER OK | JOHNP | JOHNP | | BFR | P | 3702289 |
TEAM ELECTRIC, INC. | EP | C | 08/05/2008 | panel k ok | TIMA | TIMA | | EP | C | 3720070 |
TEAM ELECTRIC, INC. | E= | C | 08/05/2008 | | TIMA | TIMA | | E= | C | 3720068 |
TEAM ELECTRIC, INC. | ER | P | 08/04/2008 | roof top units ok | ARNOLD | ARNOLD | | ER | P | 3719023 |
TEAM ELECTRIC, INC. | ER | P | 08/01/2008 | drop ceilings ok | ARNOLD | ARNOLD | | ER | P | 3718292 |
TEAM ELECTRIC, INC. | ER | P | 07/01/2008 | walls ok | TIMA | TIMA | | ER | P | 3701276 |
TEAM ELECTRIC, INC. | EUG | C | 06/19/2008 | slab ok | TIMA | TIMA | | EUG | C | 3695030 |
DENVER HTG & AIR COND INC | H= | C | 08/15/2008 | RECEIVED BALANCE REPORT. | LYNNS | LYNNS | | H= | C | 3725705 |
ALNOR INC. | H= | C | 08/12/2008 | HRP FINAL FOR WALK-IN COOLER, LINE SET AND CONDENSER. | LYNNS | LYNNS | | H= | C | 3723557 |
DENVER COMMERCIAL PLBG., INC. | H= | C | 08/11/2008 | GAS FINAL. | LYNNS | LYNNS | | H= | C | 3722621 |
DENVER HTG & AIR COND INC | H= | P | 08/11/2008 | HVAC FINAL PENDING BALANCE REPORT. NOTE: NEED PERMIT ON WALK-IN COOLER. | LYNNS | LYNNS | | H= | P | 3722619 |
DENVER HTG & AIR COND INC | H= | P | 08/04/2008 | HVAC FINAL PENDING INTERLOCKS AND BALANCE REPORT. | LYNNS | LYNNS | | H= | P | 3719035 |
DENVER HTG & AIR COND INC | HD | P | 08/01/2008 | ALL DUCT TO BE INSULATED PER GENERAL NOTES ON PLANS INCLUDING FLEXS..SEAL ENDS (VAPOR BARRIERS) PER MANUFACTURER'S INSTALLATION GUIDE. TYPE II HOOD DUCT OK. SEAL RISER JOINT ON BATH EXHAUST. | LYNNS | LYNNS | | HD | P | 3718107 |
DENVER COMMERCIAL PLBG., INC. | HI | C | 07/31/2008 | 10# TEST AND DESIGN OK. | LYNNS | LYNNS | | HI | C | 3717378 |
DENVER HTG & AIR COND INC | HD | P | 07/29/2008 | ROUGH DUCT ON GREASE DUCT, OK TO WRAP. | LYNNS | LYNNS | | HD | P | 3715771 |
DENVER HTG & AIR COND INC | HD | P | 07/25/2008 | ROUGH DUCT IN FRONT ONLY. | LYNNS | LYNNS | | HD | P | 3714157 |
R D PLUMBING LLC | P= | C | 08/11/2008 | ITEMS NOTED FROM PREVIOUS INSPECTION CORRECTED | LEE | LEE | | P= | C | 3722877 |
R D PLUMBING LLC | P= | T | 08/08/2008 | PAID (REC#820661) NOT READY--1) CANT FIND C/O FOR URINAL 2) HAND SINK BY BEVERAGE COOLER IS CROSSED 3) HAND SINK ON NORTH WALL HAS A CORRIGATED SJ EXTENTION 4) SINK NEXT TO KIT ICE BIN IS NOT SECURED TO WALL AND IS NOT CAULKED TO WALL 5) NO INFO ON ICE BENS AS TO WATER PROTECTIONS 6) FINISH 3-COMPARTMENT SINK FAUCETS 7) CANT FIND ANY OF THE REQ'D C/OS FOR SINKS PER RBC | LYNNIE | LYNNIE | | P= | T | 3722293 |
R D PLUMBING LLC | P16 | C | 07/17/2008 | Received confirmation letter from engineer and owner allowing change of floor sink manufacture to Commercial Enameling Company model # 906 and listing information. | KYE | KYE | | P16 | C | 3710168 |
R D PLUMBING LLC | PTO | C | 07/14/2008 | | LYNNIE | LYNNIE | | PTO | C | 3707673 |
R D PLUMBING LLC | PTO | T | 07/09/2008 | PAID (REC#815964) ALTERED UNDER GROUND PIPING FOR 3-COMPARTMENT SINK AND DISHWASHER--COVERED UP WITH NO TESTS- STILL NOT READY FOR TOTAL PTO BECAUSE OF THIS AREA--OTHER AREAS OK | LYNNIE | LYNNIE | | PTO | T | 3705330 |
R D PLUMBING LLC | PTO | P | 07/02/2008 | TRIP FEE NOT READY? 1) INSTALL ALL CLOSET FLANGES AND SECURE THEM TO FLOOR 2) ISOLATE ALL PEX LINES FROM METAL EDGES 3) INSTALL ALL TEST TEES/CLEANOUTS-RETEST 4) FINISH 3-COMPARTMENT SINK AND HAND SINK AREA IN BACK ROOM TO PLANS 5) FINISH SUPPORTING ALL DWV TO CODE | LYNNIE | LYNNIE | | PTO | P | 3702386 |
R D PLUMBING LLC | PB | P | 06/18/2008 | PROCEEDING AT RISK ABOUT- 1) CECO FLOOR SINKS BEING OF AN APPROVED TYPE 2) FLOOR DRAINS AND WATER CLOSETS BEING DIFFERENT THAN PLANS 3) WILL NEED AS-BUILT DRAWINGS AS TO THE GREASE LINE BEING RE-ROUTED FROM PLANS | LYNNIE | LYNNIE | | PB | P | 3694068 |
R D PLUMBING LLC | PB | P | 06/17/2008 | 1) NEED OK FROM ENG. ON THE USE OF PVC FLOOR DRAINS AND SINKS AND NOT CAST IRON 2) GREASE LINE LOST TEST 3) INSTALL AND TEST THRU ALL FLOOR DRAINS AND SINKS 4) FLOOR SINKS AND FLOOR DRIANS IN BOXES HAVE NO LISTING ON THEM (CHINA) | LYNNIE | LYNNIE | | PB | P | 3693674 |