RATE CONSTRUCTION, LLC | BIN | P | 02/20/2009 | ok to rock garage and large addition | CHRISM | CHRISM | | BIN | P | 3804351 |
RATE CONSTRUCTION, LLC | BFR | P | 02/20/2009 | framing ok in garage and large addition, floor in dining room ok to cover | CHRISM | CHRISM | | BFR | P | 3804350 |
RATE CONSTRUCTION, LLC | BFR | R | 02/18/2009 | missing truss detail for T02A, truss layout page S-3 does not match as built, brace laterals at 20' intervals, truss clip T01 trusses at mid point bearing, no inspection done on waterproof membrane under deck | CHRISM | CHRISM | | BFR | R | 3803516 |
RATE CONSTRUCTION, LLC | BFR | R | 02/17/2009 | ok to start insulation , plans not complete, need S-1 and rest of truss detail | CHRISM | CHRISM | | BFR | R | 3802813 |
RATE CONSTRUCTION, LLC | BFN | C | 10/31/2008 | EUFER INSTALLED./ 2000 PSF./ NO DRAIN REQUIRED./ALL PAPERWORK ON FILE. | RONG | RONG | | BFN | C | 3763958 |
RATE CONSTRUCTION, LLC | BFT | R | 10/28/2008 | LAYOUT DOES NOT MATCH PLAN. | RONG | RONG | | BFT | R | 3762068 |
RATE CONSTRUCTION, LLC | BFT | T | 10/27/2008 | PAID (REC#832859): NO S-1 PLAN SHEET (FOUNDATION DESIGN) ON SITE./ CALLED CALL AHEAD # AND GOT VOICE MAIL STATING CONTRACTOR HAD LOST HIS PHONE. LEFT MESSAGE. | RONG | RONG | | BFT | T | 3761525 |
RATE CONSTRUCTION, LLC | BFT | T | 10/24/2008 | PAID (REC#832624): NO SHEET S1, NO FOUNDATION DESIGN ON SITE.
| RONG | RONG | | BFT | T | 3760788 |
RATE CONSTRUCTION, LLC | BFT | R | 10/23/2008 | NEED FOUNDATION DESIGN FOR FOOTER INSPECTION. | RONG | RONG | | BFT | R | 3760185 |
C. R. BESS ELECTRIC, INC. | E= | C | 05/20/2009 | | GARYL | GARYL | | E= | C | 3836697 |
C. R. BESS ELECTRIC, INC. | ER | P | 01/22/2009 | ADDITION OK | TIMA | TIMA | | ER | P | 3793941 |
C. R. BESS ELECTRIC, INC. | ES | C | 01/22/2009 | RESIDENTIAL UNDERGROUND: 200 AMP 3/W CHANGING FROM OVERHEAD TO UNDERGROUND NEED TO CORDINATE WITH CONTRACTOR FOR CHANGE OVER C R BESS ELECTRIC | TIMA | TIMA | | ES | C | 3793940 |
C. R. BESS ELECTRIC, INC. | EUG | C | 01/22/2009 | | TIMA | TIMA | | EUG | C | 3793935 |
COLORADO GAS SYSTEMS | H= | C | 03/16/2009 | GAS PIPING ONLY, NO PERMIT CARD FOUND | TED | TED | | H= | C | 3813164 |
BRUNO'S HEATING & COOLING | HRR | C | 02/13/2009 | CORRECTION MADE, 2ND FLOOR AIR HANDLER A/C | TED | TED | | HRR | C | 3802169 |
BRUNO'S HEATING & COOLING | HRR | T | 02/12/2009 | PAID (REC#846288): 2ND FLOOR FIREPLACE COMBUSTION VENT STILL DAMAGED ON SIDE OF FIREPLACE AND IN ATTIC, (HOLES IN PIPING IN ATTIC AND PULLED APART ON SIDE) | TED | TED | | HRR | T | 3801681 |
COLORADO GAS SYSTEMS | HC | C | 02/11/2009 | OK FOR 2LB SYSTEM, NEED LETTER | TED | TED | | HC | C | 3801204 |
COLORADO GAS SYSTEMS | HO | C | 02/11/2009 | 60LB TEST ON UNDER GROUND LINE FROM METER TO HOUSE FOR 2LB SYSTEM | TED | TED | | HO | C | 3801182 |
BRUNO'S HEATING & COOLING | HWP | P | 02/11/2009 | PIPING FOR 2ND FLOOR OK | TED | TED | | HWP | P | 3801011 |
COLORADO GAS SYSTEMS | HI | P | 02/10/2009 | NEED BOILER BTU LOAD AND NEED TOTAL BTU LOAD ON P.E. RUN FROM METER, NOTE: NEW 1'' RUN TO ADDITTION FOR BOILER AND 2-FIREPLACES, (FIREPLACE BTU LOAD-60,000, 1'' 50FEET) | TED | TED | | HI | P | 3800814 |
BRUNO'S HEATING & COOLING | HRR | R | 02/10/2009 | WAIVE TRIP FEE, HAD ANOTHER INSPECTION, 2ND FLOOR FIREPLACE COMBUSTION AIR VENT DAMAGED AND NOT THOUGH OUTSIDE WALL, PRIMARY CONDENSATE DRAIN NOT RUN FOR AIR HANDLER A/C ON 2ND FLOOR, NOTE: BOILER VENT RUN ONLY, KITCHEN ADDITION TO HAVE ELECTRIC HEAT | TED | TED | | HRR | R | 3800790 |
BRUNO'S HEATING & COOLING | HRR | R | 02/05/2009 | INSTALL BOILER AND VENT, FINISH FRAMING 2ND FLOOR FIREPLACE, ROOF PAPER ON 2ND FLOOR FIREPLACE, FINISH COMBUSTION AIR VENT TO 2ND FLOOR FIREPLACE, NEED TO KNOW HOW NEW KITCHEN ADDITION IS TO BE HEATED, RUN A/C CONDENSATE DRAIN, NOTE: 60LB TEST ON NEW 2ND FLOOR HWP PIPING, AIR HANDLER ON 2ND FLOOR FOR A/C | TED | TED | | HRR | R | 3799265 |
BRUNO'S HEATING & COOLING | HWP | C | 11/24/2008 | OK TO COVER INFLOOR PIPING, NO PERMIT CARD FOUND, NOTE: BAD CALL AHEAD NUMBER | TED | TED | | HWP | C | 3774548 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 05/14/2009 | new addition ok | TIM | TIM | | P= | C | 3834593 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 01/12/2009 | CORRECTIONS MADE.---STILL NO ACCOMMODATIONS FOR CONDENSATE. | SCOTT | SCOTT | | PTO | C | 3790082 |
PACIFIC PLUMBING, INCORPORATED | PTO | T | 01/08/2009 | PAID (REC#841764): NO PERMIT IN SIGHT.---COLD SIDE OF WATER SYSTEM STILL, EXCEEDS 9.5 WSFU'S. ONLY ALLOWED TO HAVE 9.5 ON 3/4'' PIPE. | SCOTT | SCOTT | | PTO | T | 3788934 |
PACIFIC PLUMBING, INCORPORATED | PTO | P | 12/31/2008 | WATER PIPING IS UNDERSIZED. IF A CONDENSING BOILER IS USED, A MEANS FOR CLEAR WATER WASTE WILL HAVE TO BE ADDRESSED. OUTSIDE WALL BEHIND THE SHOWER VALVE WILL NEED R-19 INSULATION, WITH HIGH R-VALUE, POSSIBLY FOAM BOARD, TO PROTECT THE SHOWER VALVE. | SCOTT | SCOTT | | PTO | P | 3786592 |
BYRNE PLUMBING & HEATING, LLC. | PB | C | 11/13/2008 | NO WATERLINE BELOW THE SLAB. | SCOTT | SCOTT | | PB | C | 3769285 |