CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/28/2023 | ANNUAL 7/23 - OTIS W/PEAK SERVICE - NO VISIBLE CODE ISSUES (Receipt #2020198) | MATTM | MATTM | | H01 | C | 7955668 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/06/2023 | HO2 -- ANNUAL 7/22 -- OTIS W/ PEAK SERVICE -- SEE PREVIOUS NOTES | BENH | BENH | | H02 | C | 7764405 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/21/2022 | ANNUAL 7/22 -- OTIS W/ PEAK SERVICE -- / NO MAINTENANCE TASK LOGS FOR 2022 WITHIN THE MCP / NON ELEVATOR RELATED ITEMS NEED TO BE REMOVED FROM THE MACHINE ROOM / OPEN ELECTRICAL BOX IN MACHINE ROOM NEEDS COVERED / CAR POSITION SENSING DEVICE COVER IS OFF AND LEAVING EXPOSED WIRING ON CAR TOP / BUILDING TO KEEP MONTHLY FIREFIGHTERS’ EMERGENCY OPERATION AND QUARTERLY EMERGENCY PHONE TEST LOGS UP TO DATE (Receipt #1922360) | DUSTINS | DUSTINS | | H01 | C | 7618072 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/27/2022 | HO2 -- ANNUAL 7/21 -- TKE W/ PEAK SERVICE (cat 1 -- 7/22) | BENH | BENH | | H02 | C | 7426507 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/21/2021 | ANNUAL 07/2021-- TKE WITH PEAK SERVICE-- (note: emergency phone connected on third attempt) (Receipt #1831364) | MIKEM | MIKEM | | H01 | C | 7216968 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/30/2021 | H02 -- CAT1 -- 7/20 -- TKE W/ PEAK SERVICE cat 1 7/21 | ROBERTV | ROBERTV | | H02 | C | 7021414 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/10/2020 | ITEMS HAVE BEEN ADDRESSED, THIS VISIT SKIPPED IN LIEU OF WITNESS TEST PERFORMED 7/2020 (Receipt #1735808) | ROBERTV | ROBERTV | | H01 | C | 6803095 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H06 | C | 07/17/2020 | WITNESSED CATEGORY 1 TESTING W/ PEAK ELEVATOR - ELEVATOR WAS REMOVED FROM SERVICE DUE TO LENGTH OF VIOLATIONS AND NON-COMPLIANCE. ITEMS LISTED NEED TO BE REMEDIED BEFORE ELEVATOR CAN BE RETURNED TO SERVICE: EMERGENCY PHONE STILL NOT WORKING. NO MAINTENANCE CONTROL PROGRAM ONSITE. MISSING ELEVATOR WIRING DIAGRAMS. MISSING FIRE SERVICE PHASE I OPERATION INSTRUCTIONS. NEED QUARTERLY EMERGENCY PHONE TESTING LOG ONSITE W/ MAINTENANCE RECORDS. LOWEST LEVEL KEYED HALL CALL STATION NOT WORKING. | ROBERTV | ROBERTV | | H06 | C | 6641945 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/30/2020 | H02 -- No access due to COVID-19, See previous inspection items - (RV: email sent to Superintendent and Dave Strehlow 6/18/2020 regarding compliance within 60 days or elevators will be removed from service) | ROBERTV | ROBERTV | | H02 | C | 6622191 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/30/2019 | RP--2--17--OTIS --PEAK SERVICE --CATEGORY 1 TEST EXPIRED --CATEGORY 5 WITNESSED EXPIRED --PHONE IN CAB NOT WORKING --BOTTOM FLOOR KEYED CALL STATION NOT WORKING--30 DAYS TO ADDRESS THESE ISSUES (Receipt #1652828) | JOHNW | JOHNW | | H01 | C | 6439633 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/24/2019 | RP--2--17--OTIS --PEAK SERVICE --PHONE IN CAB NOT WORKING --ANNUAL CAT 1 EXPIRED --REMOVE NON ELEVATOR STORED ITEMS IN MACHINE ROOM--WITNESSED TEST REQUIRED | JOHNW | JOHNW | | H02 | C | 6241012 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/28/2018 | RP--2--17--OTIS --PEAK SERVICE --RELIEF PRESSURE TEST EXPIRED --PHONE IN CAB NOT WORKING --PHONE NEEDS TO BE RE- MOUNTED IN CAB (Receipt #1566288) | JOHNW | JOHNW | | H01 | C | 6065050 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/27/2018 | RP--2--17--OTIS --PEAK SERVICE --PEAK SERVICE --RELIEF PRESSURE TEST EXPIRED | JOHNW | JOHNW | | H02 | C | 5886494 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/20/2017 | RP--2--17--OTIS --PEAK SERVICE --PHONE IN CAB NOT WORKING MUST BE RE MOUNTED ON THE PHONE COMPARTMENT AND BE PROGRAMED TO PEAK'S PHONE SERVICE --MISSING MAINTENANCE CONTROL PROGRAM IN THE MACHINE ROOM (Receipt #1472266) | JOHNW | JOHNW | | H01 | C | 5718130 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/21/2017 | RP--2--17--OTIS --PEAK SERVICE --PHONE IN CAB NOT WORKING--NON ELEVATOR STORAGE IN THE ELEVATOR MACHINE ROOM. STATE ID# CP08-000849--HIGH SCHOOL CONTACT IS WILL V. 499-6561 | JOHNW | JOHNW | | H02 | C | 5542627 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | HE16 | C | 02/14/2017 | PRESSURE RELIEF TEST COMPLETED 2/17 | ERIC | ERIC | | HE16 | C | 5414957 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/22/2016 | RP--2--14--OTIS --PEAK SERVICE --PRESSURE RELIEF TEST WAY OVERDUE AND MUST BE COMPLETED NOW--MISSING BULB GUARDS IN CAB --THERE IS NO MCP PAPERWORK IN THE MACHINE ROOM (Receipt #1391129) | JOHNW | JOHNW | | H01 | C | 5375281 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/27/2016 | HO2 | JOHNW | JOHNW | | H02 | C | 5231323 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/22/2015 | ELEVATOR STOPPED WORKING WHEN WE WENT TO RIDE IT DID NOT COMPLETE ELEVATOR INSPECTION (Receipt #1305292) | JOHNW | JOHNW | | H01 | C | 5103447 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/26/2015 | BUILDING IS BEING REMODELED WILL CALL WHEN POWER IS BACK ON | JOHNW | JOHNW | | H02 | C | 4981423 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/22/2014 | RP--2--14--OTIS --PEAK SERVICE (Receipt #1238460) | JOHNW | JOHNW | | H01 | C | 4876421 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 07/30/2014 | HO2 | JOHNW | JOHNW | | H02 | C | 4786526 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H06 | C | 02/13/2014 | WITNESSED 5 YEAR SAFETY TEST. EMERGENCY PHONE, ALARM BELL AND EMERGENCY LIGHTS NOT WORKING, NEED FIRE FIGHTERS PHASE 1 INSTRUCTION PLACARD | ERIC | ERIC | | H06 | C | 4686885 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/31/2013 | NEED 5YR (Receipt #1173237) | JOHNW | JOHNW | | H01 | C | 4665199 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/28/2013 | HO2 | JOHNW | JOHNW | | H02 | C | 4553225 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/28/2012 | RP--12--12--OTIS --SCHINDLER SERVICE--ELEVATOR WAS OUT OF SERVICE AT TIME OF INSPECTION | JOHNW | JOHNW | | H01 | C | 4446332 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/21/2012 | RP--12--11--OTIS --SCHINDLER SERVICE --EMERGENCY LIGHT OUT IN CAB | JOHNW | JOHNW | | H02 | C | 4329677 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/21/2011 | RP--12--11--OTIS --SCHINDLER SERVICE --CONTROL PANEL INSIDE THE CAR IS LOOSE --RUDY AT 499-6561 (Receipt #1018834) | JOHNW | JOHNW | | H01 | C | 4251866 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/20/2011 | RP--7--10--OTIS--SCHINDLER SERVICE--PHONE IN CAR NOT WORKING | JOHNW | JOHNW | | H02 | C | 4166303 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/21/2010 | RP--7--10--OTIS --SCHINDLER SERVICE DOWN AT TIME OF INSPECTION (Receipt #952028) | JOHNW | JOHNW | | H01 | C | 4088885 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/25/2010 | RP--9--09--OTIS --SCHINDLER SERVICE--ELEVATOR WAS NOT RUNNING AT TIME OF INSPECTION | JOHNW | JOHNW | | H02 | C | 4000875 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/30/2009 | 9--09--OTIS --SCHINDLER SERVICE--FIRE SERVICE NOT WORKING PROPERLY--AFTER ELEVATOR WAS PUT INTO PH1 AND PH2 FIRE SERVICE THE ELEVATOR STOPPED WORKING (Receipt #890954) | JOHNW | JOHNW | | H01 | C | 3927486 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H02 | C | 06/25/2009 | OTIS. SCHINDLER SERVICE RP 2/09. CATCH CANS IN PIT OVERFLOWING, NEED BULB GUARDS IN CAR AND EMERGENCY PHONE DOES NOT WORK | ERIC | ERIC | | H02 | C | 3850698 |
CHEYENNE MOUNTAIN SCHOOL DISTRICT 12 | H01 | C | 12/05/2008 | rp--9--08--otis and schindler service--emergency phone not working --catch cans overflowing in pit --bulb guards in car missing --signs at all call stations ( do not use elevator in case of a fire)--remove non elevator storage for machine room---machine room missing fire extinguisher---machine room door missing---;adjust door at bottom landing--emergency car light not working (Receipt #838302) | JOHNW | JOHNW | | H01 | C | 3778683 |