J.E. DUNN ROCKY MOUNTAIN, INC. | B= | C | 04/29/2010 | | BERTW | BERTW | | B= | C | 3973992 |
J.E. DUNN ROCKY MOUNTAIN, INC. | B= | P | 03/23/2010 | Temp CO: WAITING ON LANDSCAPING ( Expires: 4/22/2010 12:00:00 AM) | KIM | KIM | | B= | P | 3957714 |
J.E. DUNN ROCKY MOUNTAIN, INC. | B= | P | 03/23/2010 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: rdassero@springsgov.com or 385-7396), External Agency Inspection Z= by ZONING is not Completed yet (Contact: ngadson@springsgov.com or 385-5982), External Agency Inspection HD= by HEALTHDEPT is not Completed yet, E LIGHT ELECTRIC SERVICES, INC Electrical Final Inspection is not Completed yet, HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet. Need all other final inspections, No latch hardware at exit gate | MIKE | MIKE | | B= | P | 3957233 |
J.E. DUNN ROCKY MOUNTAIN, INC. | B= | P | 03/19/2010 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: rdassero@springsgov.com or 385-7396), External Agency Inspection Z= by ZONING is not Completed yet (Contact: ngadson@springsgov.com or 385-5982), External Agency Inspection HD= by HEALTHDEPT is not Completed yet, ARTISAN PIPE SYSTEMS, INC. Mechanical Final Inspection is not Completed yet, ARTISAN PIPE SYSTEMS, INC. Plumbing Final Inspection is not Completed yet, E LIGHT ELECTRIC SERVICES, INC Electrical Final Inspection is not Completed yet, HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet. stair landings-handrailings and guards-under sink knee protection-signage @ restrooms-panic hardware on wooden gates that are in the egress pathway -- Schedule a new Building Final when above items are complete. | BERTW | BERTW | | B= | P | 3956244 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | C | 03/19/2010 | | BERTW | BERTW | | BFR | C | 3956229 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BSP | P | 03/09/2010 | DRY STORAGE INSULATION OK WALLS | BERTW | BERTW | | BSP | P | 3952216 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | P | 03/09/2010 | DRY STORAGE AREA FRAMING AND EXTERIOR INSULATION OK PER DESIGN | BERTW | BERTW | | BFR | P | 3952215 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BSP | T | 03/04/2010 | PAID (REC#898920) ADDITIONAL PLAN REVIEW TIME: $50 From: DALEH splice for change to gas piping plan | DALEH | DALEH | | BSP | T | 3950264 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BSP | T | 03/04/2010 | PAID (REC#898904) ADDITIONAL PLAN REVIEW TIME: $50 From: SHELLEY added dry storage addition | SHELLEY | SHELLEY | | BSP | T | 3950226 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | P | 03/03/2010 | ENGINEERING OK FOR SIGN WALL FRAMING DETAILS/NEED APPROVED DRAWINGS FOR DRY STORAGE AREA FRAMING AND INSPECTED-PROVIDE ENGINEERING FOR WALLS AND ROOF BEARING ON A THICKENED SLAB/SOFFIT FRAMING OK @ HOOD AREA | BERTW | BERTW | | BFR | P | 3950039 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | P | 02/09/2010 | REVIEWED NORTH TRELLIS FRAMING-STILL NEED INSPECTION | BERTW | BERTW | | BFR | P | 3942087 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BIN | C | 02/08/2010 | | BERTW | BERTW | | BIN | C | 3941714 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | P | 02/08/2010 | TRELLIS FRAMING OK-EXCEPT FOR 2 POSTS THAT STILL NEED TO BE SET/revised 2-9-10 need north trellis inspection | BERTW | BERTW | | BFR | P | 3941710 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BIN | P | 02/04/2010 | ROOF ONLY OK | BERTW | BERTW | | BIN | P | 3940490 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | P | 02/04/2010 | NEED ELECTRIC AND ALL OTHER ROUGH INSPECTIONS COMPLETED AS WELL AS PREVIOUS COMMENTS | BERTW | BERTW | | BFR | P | 3940488 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFD | C | 01/29/2010 | ENGINEER INSPECTION REPORT ON FILE | BERTW | BERTW | | BFD | C | 3938637 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | P | 01/28/2010 | WALLS AND ROOF SYSTEM OK PENDING ALL OTHER ROUGHS COMPLETED/STRUCTURAL WELD REPORT ON FILE-NEED TRELLIS (X2) FRAMING INSPECTED-NEED ENGINEERING STAMP ON FRAMING MODIFICATIONS TO SIGN WALL OTHERWISE OK | BERTW | BERTW | | BFR | P | 3938068 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFN | C | 01/28/2010 | NO DRAIN | BERTW | BERTW | | BFN | C | 3938060 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BSP | L | 01/14/2010 | PAID (REC#894369) ADDITIONAL PLAN REVIEW TIME: $50 From: TCRIPPEN a new slpice page see schedule | TCRIPPEN | TCRIPPEN | | BSP | L | 3933001 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BSP | T | 01/13/2010 | PAID (REC#894369) PLAN SPLICE FEE: $75 by: MICHAEL for Construction: Splice to structural approved | MICHAELA | MICHAELA | | BSP | T | 3931949 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | P | 01/11/2010 | SHEAR WALLS OSB NAILING OK/EXCEPT FOR SIGN WALL FRAMING-OK FOR ENGINEER TO DO INSPECTION-FRAMING DOESNT MATCH DESIGN/MISSING ANCHOR BOLTS @ PLATE BREAKS/STILL NEED FULL FRAMING INSPECTION-COMPLETED DRAIN INSPECTION AND NEW DESIGN FOR ROOF FRAMING ASLO WELD INSPECTION OF STRUCTURAL COMPONENTS | BERTW | BERTW | | BFR | P | 3931320 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFR | R | 01/05/2010 | SHEAR WALLS NEED HOLD DOWNS AS SPECIFIED ON PLANS/NEED APPROVED ROOF FRAMING DESIGN DUE TO REORIENTATION OF ROOF DECKING AND ADDED RAFTERS,HANGERS ETC./NO FRAMING INSPECTION DONE | BERTW | BERTW | | BFR | R | 3929146 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFN | P | 12/01/2009 | FOOTINGS OK/STAMPED SOILS ON FILE/STILL NEED DRAIN REQUIREMENTS AND UFER INSPECTION HISTORY | BERTW | BERTW | | BFN | P | 3918096 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFI | C | 11/20/2009 | R-8 RIGID VERTICALLY OK | BERTW | BERTW | | BFI | C | 3914384 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFT | C | 11/20/2009 | | BERTW | BERTW | | BFT | C | 3914381 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFN | P | 11/20/2009 | WALLS COMPLETE/NEED STAMPED SOILS REPORT FOR DRAIN REQUIREMENTS/NEED UFER GROUND INSPECTION IN HISTORY | BERTW | BERTW | | BFN | P | 3914378 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFT | C | 11/20/2009 | | BERTW | BERTW | | BFT | C | 3914366 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFI | P | 11/12/2009 | SOUTH WALLS OK | BERTW | BERTW | | BFI | P | 3910902 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFN | P | 11/12/2009 | WEST RETAINING WALL OK | BERTW | BERTW | | BFN | P | 3910900 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFT | P | 11/12/2009 | 6 INTERIOR PADS OK | BERTW | BERTW | | BFT | P | 3910897 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFN | P | 11/05/2009 | 4 LINE SOUTH PAST A LINE THRU LINE 1B OK | BERTW | BERTW | | BFN | P | 3907994 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFT | P | 11/05/2009 | CTL PRELIMINARY SOILS 3000PSF/NEED STAMPED OPEN HOLE/FOOTINGS COMPLETE NEED INTERIOR PADS INSPECTED AND UFER INSPECTED | BERTW | BERTW | | BFT | P | 3907992 |
J.E. DUNN ROCKY MOUNTAIN, INC. | BFT | R | 11/02/2009 | 3000PSF DESIGN NO OPEN HOLE PROVIDED/INSPECTED SHEET S2.00 FOOTINGS MARKED IN BLUE/IAN IS HAVING CTL DO OPEN HOLE @ 3:30 PM/POUR @ OWN RISK/NEED UFER INSPECTED | BERTW | BERTW | | BFT | R | 3906178 |
E LIGHT ELECTRIC SERVICES, INC | E= | C | 03/24/2010 | | JOSEPH | JOSEPH | | E= | C | 3958005 |
E LIGHT ELECTRIC SERVICES, INC | E= | P | 03/23/2010 | CORDS BURIED IN WALLS TO HEAT LAMPS, INSTALL 4/0 AL FROM XFMR TO PANEL GG1 | MATTHEW | MATTHEW | | E= | P | 3957469 |
E LIGHT ELECTRIC SERVICES, INC | E= | P | 03/22/2010 | | DEAN | DEAN | | E= | P | 3957001 |
E LIGHT ELECTRIC SERVICES, INC | ER | P | 03/12/2010 | drop ceilings ok | BRET | BRET | | ER | P | 3953636 |
E LIGHT ELECTRIC SERVICES, INC | ER | P | 03/08/2010 | rtu and dry storage room rough ok | BRET | BRET | | ER | P | 3951468 |
E LIGHT ELECTRIC SERVICES, INC | ER | P | 02/19/2010 | walls complete. | BRET | BRET | | ER | P | 3945661 |
E LIGHT ELECTRIC SERVICES, INC | EUG | P | 02/19/2010 | eug at service ok, | BRET | BRET | | EUG | P | 3945660 |
E LIGHT ELECTRIC SERVICES, INC | ER | P | 02/08/2010 | half wall compete lacking service wall | BRET | BRET | | ER | P | 3941633 |
E LIGHT ELECTRIC SERVICES, INC | ER | P | 02/04/2010 | walls except griddle half wall and service wall | BRET | BRET | | ER | P | 3940859 |
E LIGHT ELECTRIC SERVICES, INC | ER | P | 01/12/2010 | roof rough and ufer ok | BRET | BRET | | ER | P | 3931739 |
E LIGHT ELECTRIC SERVICES, INC | ESL | C | 01/04/2010 | interior slab complete | BRET | BRET | | ESL | C | 3928490 |
E LIGHT ELECTRIC SERVICES, INC | EUG | P | 12/17/2009 | slb s.w 1" conduits into kitchen. | BRET | BRET | | EUG | P | 3924109 |
E LIGHT ELECTRIC SERVICES, INC | EUG | P | 12/04/2009 | esl bathroom ok electric and f.a conduit. | BRET | BRET | | EUG | P | 3919613 |
E LIGHT ELECTRIC SERVICES, INC | EUG | P | 11/10/2009 | ok to transformer. will need to check pull box when installed. | BRET | BRET | | EUG | P | 3909972 |
E LIGHT ELECTRIC SERVICES, INC | EUG | P | 11/03/2009 | partial leave area at pull box open and from drain west. take pictures of conduit around rock. pictures ok this time only because need backfill for pedestrian traffic. | BRET | BRET | | EUG | P | 3906529 |
HVAC SOLUTIONS, INC. | H= | C | 03/25/2010 | | JON | JON | | H= | C | 3958566 |
HVAC SOLUTIONS, INC. | H= | P | 03/24/2010 | NEED ENGINEER TO ADDRESS DUCT CHANGES ON TYPE ONE EXHAUST. HOODS AND MAKEUP AIR NOT PROPERLY INTERLOCKED, CALLED CONTRACTOR AND NOTIFIED ELECTRICIAN ON SITE. RECALL INSPECTION. | JON | JON | | H= | P | 3958158 |
HVAC SOLUTIONS, INC. | H= | P | 03/23/2010 | PARTIAL PENDING THE REFRIGERATION COMPLETION. | JEFFB | JEFFB | | H= | P | 3957302 |
ARTISAN PIPE SYSTEMS, INC. | H= | C | 03/22/2010 | ALL GAS LINES ARE COMPLETE. | JEFFB | JEFFB | | H= | C | 3956652 |
HVAC SOLUTIONS, INC. | H= | P | 03/19/2010 | REFRIGERATION PERMIT NEEDS TO BE ADDED TO THIS PERMIT. THE WATER HEATER GAS LINE NEEDS TO BE CHANGED TO SOLID BECAUSE THE FLEX LINE USED IS TOO SMALL. THE PIZZA OVEN SAFETY LINE NEEDS TO BE INSTALLED. NOTES: ALL 3 HOODS ARE GOOD WITH WRAP AND CLEARANCES. FOR THE ROOF DUCT - THE WRAP INSULATION ON THE DUCT AND THE SLOPE OF THE EXHAUST DUCT ARE GOOD. THE BALANCE REPORT HAS BEEN RECEIVED. | JEFFB | JEFFB | | H= | P | 3956258 |
HVAC SOLUTIONS, INC. | HD | P | 03/09/2010 | EXTERIOR GREASE DUCT TO BE INSULATED FOR PREVENTION OF GREASE ACCUMULATION,CORROSION PROTECTION ETC. SEE ALL OF THE FOLLOWING 2003 IMC CODE SECTIONS, 506.2, 506.3.7, 506.3.10 AND 604.12. WILL VERIFY DUCT SLOPE AT SQUARE ELBOW THROUGH ACCESS DOOR ON ROOF PRIOR TO FINAL. OK FOR GREASE WRAP AT BOTH TYPE ONE HOODS, CALL GREASE WRAP INSPECTION PRIOR TO COVER. NEED PLANS TO SHOW DUCT CHANGE FROM ROUND TO RECTANGULAR ON ROOF FOR TYPE ONE UTILITY FAN. TYPE 2 DUCT OK FOR OVEN HOOD. SEE OVEN AND GAS LINE SOLENOID AT FINAL. WILL NEED PERMITS FOR WALK IN COOLERS AND INSPECTIONS BEFORE FINAL. | JON | JON | | HD | P | 3952235 |
HVAC SOLUTIONS, INC. | HD | P | 03/08/2010 | GREASE DUCT TO BE CONSTRUCTED WITH MINIMUM 1/4" PER SLOPE. NEED TO LIGHT CHECK ALL AGAIN AND ENSURE NO HOLES PRIOR TO INSPECTION. FAN CONNECTIONS TO BE IN AN APPROVED MANNER. NEED TO SEAL UNDER UPBLAST FAN TO CODE. WILL ALSO NEED PROPER SAFETY RAIL FOR MUA UNIT. | JON | JON | | HD | P | 3951441 |
HVAC SOLUTIONS, INC. | HD | P | 03/03/2010 | SOUTH WALL METAL STUDS BEHIND HOOD ONLY | JON | JON | | HD | P | 3950158 |
HVAC SOLUTIONS, INC. | HD | P | 02/18/2010 | NEED LISTING INFORMATION OR INSTRUCTIONS FROM HOOD MANUFACTURER TO DETERMINE IF THESE TYPE 1 HOODS CAN INSTALLED ON WOOD CONSTRUCTED WALLS. OTHER WISE A NON COMBUSTIBLE WALL BEHIND AND AT SIDE OF HOOD WILL BE REQUIRED. IF SIDE OF HOOD DOES NOT HAVE A 3'' FACTORY STAND OFF, THE 18'' CLEARANCE TO COMBUSTIBLES WILL BE REQUIRED. BEFORE FINAL NEED GUARD RAILS FOR ANY EQUIPMENT WITHIN 10 FEET OF A 30" DROP ON ROOF, THESE RAILS TO CONSTRUCTED AS SHOWN IN THE 2003 IMC. ADDED NOTE 3-1-10: DETAILS FOR TYPE ONE HOODS ARE TO BE RUN THROUGH PLAN CHECK AND FROM 1ST LOOK DETAILS DO NOT APPEAR TO MEET CLEARANCE TO COMBUSTIBLES OR MEET CODE FOR HOOD AND GREASE DUCT ENCLOSURES. ADVISED CONTRACTORS TO CONSULT ARCHITECT AND MECHANICAL ENGINEERS. | JON | JON | | HD | P | 3945631 |
ARTISAN PIPE SYSTEMS, INC. | HI | C | 02/16/2010 | All tested good | JACK | JACK | | HI | C | 3943945 |
ARTISAN PIPE SYSTEMS, INC. | HI | P | 02/08/2010 | 60 LB TEST O.K. ON TWO INCH SERVICE LINE TO OTHER STRUCTURE, 10 LB TEST O.K. FOR MAIN LOW PRESS. TRUNK TO WATER HEATER , THREE RTU'S AND MAKE UP AIR UNIT AND ONE FUTURE STUB. NEED TO HAVE APPROVED PLANS ON SITE AND PLANS TO MATCH JOB. ADDED NOTE: 3-1-10 MADE JOB SUPER AND HVAC CONTRACTOR AWARE OF GAS LINE SOLENOID REQUIREMENT AT OVEN. | JON | JON | | HI | P | 3941600 |
HVAC SOLUTIONS, INC. | HD | P | 01/25/2010 | HARD LID EXHAUST AND TRANSFER DUCTS ONLY | JON | JON | | HD | P | 3936388 |
ARTISAN PIPE SYSTEMS, INC. | HO | P | 11/09/2009 | BACK FILL FIRST 58 FEET OF 2" UNDERGROUND PE AT OWN RISK. HAS TRACER AND NO TEST, DUE TO HAVING TO KEEP GAS ON LINE FOR OTHER BUILDINGS. | JON | JON | | HO | P | 3909315 |
ARTISAN PIPE SYSTEMS, INC. | PTO | C | 03/22/2010 | | JOEL | JOEL | | PTO | C | 3956586 |
ARTISAN PIPE SYSTEMS, INC. | P= | C | 03/22/2010 | WILL NEED SEPERATE PERMIT FOR IRRIGATION BFP | JOEL | JOEL | | P= | C | 3956580 |
ARTISAN PIPE SYSTEMS, INC. | PTO | P | 01/28/2010 | all minus island. | MARTY | MARTY | | PTO | P | 3937860 |
ARTISAN PIPE SYSTEMS, INC. | PB | C | 12/21/2009 | test was ok,concrete blankets were covering gauge. | MARTY | MARTY | | PB | C | 3924848 |
ARTISAN PIPE SYSTEMS, INC. | PB | P | 12/18/2009 | no test plans or permit. | MARTY | MARTY | | PB | P | 3924475 |
ARTISAN PIPE SYSTEMS, INC. | PB | P | 11/30/2009 | south side. | MARTY | MARTY | | PB | P | 3917426 |