DISTINCTIVE CUSTOM HOMES | B= | C | 12/13/2010 | | JIMA | JIMA | | B= | C | 4084445 |
DISTINCTIVE CUSTOM HOMES | B= | P | 12/10/2010 | Temp CO: bank closing ( Expires: 1/9/2011 12:00:00 AM) | KIM | KIM | | B= | P | 4083513 |
DISTINCTIVE CUSTOM HOMES | B= | P | 12/10/2010 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. need foam covered in ut room -- Schedule a new Building Final when above items are complete. | JIMA | JIMA | | B= | P | 4083455 |
DISTINCTIVE CUSTOM HOMES | B= | P | 12/09/2010 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. need dbl fringer groove for garage hand rail / cover foam in ut room / need hole repaired between 2 attics -- Schedule a new Building Final when above items are complete. | JIMA | JIMA | | B= | P | 4083005 |
DISTINCTIVE CUSTOM HOMES | BSP | P | 12/07/2010 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical: splice to change to geo thermal | DALEH | DALEH | | BSP | P | 4081917 |
DISTINCTIVE CUSTOM HOMES | BSP | T | 12/07/2010 | PAID (REC#949778) PLAN SPLICE FEE: $50 by: JAY for Construction: REVISE PLANS AND RESCK FOR SPRAY FOAM W/ VARIANCE | JAY | JAY | | BSP | T | 4081889 |
DISTINCTIVE CUSTOM HOMES | BIN | C | 08/23/2010 | variance by final for non-vented attic | CHRISM | CHRISM | | BIN | C | 4028368 |
DISTINCTIVE CUSTOM HOMES | BFR | C | 08/23/2010 | | CHRISM | CHRISM | | BFR | C | 4028366 |
DISTINCTIVE CUSTOM HOMES | BFR | R | 08/13/2010 | ok to insulate, block OH door brackets, 2-H2.5t at B-3 and B-4, TBE6s at center bearing AV1 trusses, QQ girders missing MTSC28 straps to columns, hanger joists at stair landing, draftstop floor trusses at 1500 sq' | CHRISM | CHRISM | | BFR | R | 4024555 |
DISTINCTIVE CUSTOM HOMES | BLA | C | 07/29/2010 | | JIMA | JIMA | | BLA | C | 4016750 |
DISTINCTIVE CUSTOM HOMES | BTR | C | 07/19/2010 | | CHRISM | CHRISM | | BTR | C | 4011520 |
DISTINCTIVE CUSTOM HOMES | BSP | P | 06/17/2010 | front and rear porch roofs, deck frame and columns | CHRISM | CHRISM | | BSP | P | 3996827 |
DISTINCTIVE CUSTOM HOMES | BSP | P | 06/07/2010 | (2) 42" pads with plister steel ok to pour, didnt find permit card | ED | ED | | BSP | P | 3991425 |
DISTINCTIVE CUSTOM HOMES | BFD | C | 03/05/2010 | | DALE | DALE | | BFD | C | 3950809 |
DISTINCTIVE CUSTOM HOMES | BFI | C | 03/05/2010 | | DALE | DALE | | BFI | C | 3950807 |
DISTINCTIVE CUSTOM HOMES | BFN | C | 03/02/2010 | design on file / isolate / float / eufer / drain usable and common wall | JIMA | JIMA | | BFN | C | 3949392 |
DISTINCTIVE CUSTOM HOMES | BFT | C | 02/26/2010 | pads ok / need deck piers when ready | JIMA | JIMA | | BFT | C | 3948352 |
WINTERS ELECTRIC, INC. | E= | C | 12/06/2010 | kitchen countertop spacing ok'd | MATTHEW | MATTHEW | | E= | C | 4080874 |
WINTERS ELECTRIC, INC. | E= | R | 12/03/2010 | outlet spacing in office, outlet spacing kitchen countertop, need working clearance and correct size circuit for steamer, no power north exterior outlet, need 2 pole 25 amp breaker for fire pump----- no a/c; geo-thermal installed | MATTHEW | MATTHEW | | E= | R | 4080365 |
WINTERS ELECTRIC, INC. | E= | L | 12/02/2010 | not ready | MATTHEW | MATTHEW | | E= | L | 4079605 |
WINTERS ELECTRIC, INC. | ER | C | 08/05/2010 | FINISHED BASEMENT, PERMIT PRIOR TO APRIL 1ST | GARYL | GARYL | | ER | C | 4020162 |
WINTERS ELECTRIC, INC. | ES | C | 05/19/2010 | Residential Underground: 2-200A, WINTERS ELECT | GARYL | GARYL | | ES | C | 3983408 |
WINTERS ELECTRIC, INC. | EUG | P | 05/19/2010 | SERVICE TRENCH OK TO COVER | GARYL | GARYL | | EUG | P | 3983401 |
MARATHON PLUMBING & HEATING INC. | H= | C | 12/08/2010 | | LEE | LEE | | H= | C | 4082181 |
BARKER HEATING, INC. | H= | P | 12/07/2010 | Need heat calc's for house, mechanical final complete finished basement | JACK | JACK | | H= | P | 4081624 |
MARATHON PLUMBING & HEATING INC. | HWP | P | 08/10/2010 | OK TO COVER 1ST FLOOR | TED | TED | | HWP | P | 4022406 |
BARKER HEATING, INC. | HC | C | 08/10/2010 | OK FOR METER | TED | TED | | HC | C | 4022399 |
BARKER HEATING, INC. | HRR | C | 08/10/2010 | BY FINAL NEED CALCS CHANGED TO A GEOTHERMO SYSTEM WITH NO BACK UP SYSTEM | TED | TED | | HRR | C | 4022398 |
BARKER HEATING, INC. | HRR | P | 08/06/2010 | PROVIDE APPROVED PRINTS. PROVIDE RESIDENTIAL EQUIPMENT CERTIFICATE. DRYER BOX DOES NOT ALLOW FOR REQUIRED INSULATION ON GARAGE WALL. PROVIDE INFORMATION IN TYPE OF BACKER BOARD BEING INSTALLED ON FIREPLACES, SHEET ROCK, CONCRETE BOARD? TYPE OF MANTLE BEING INSTALLED ON BATH SIDE OF MASTER BEDROOM FIREPLACE? WOOD BURNER FIREPLACE NEEDS METAL STRIPS ON FRONT OF RAISED PLATFORM, SEE FIGURE 7.2. | NANCY | NANCY | | HRR | P | 4020671 |
MARATHON PLUMBING & HEATING INC. | HI | C | 07/29/2010 | W/H, RNG, BBQ, FUTURE GARAGE UNIT HEATER, FUTURE GAS LOG, 2- F/P (GEO THERMO HEAT) | LEE | LEE | | HI | C | 4016714 |
MARATHON PLUMBING & HEATING INC. | HWP | P | 04/22/2010 | FOUR 70 LB TESTS OK IN BASEMENT. OK TO POUR BASEMENT. | NANCY | NANCY | | HWP | P | 3970843 |
MARATHON PLUMBING & HEATING INC. | P= | C | 12/08/2010 | | LEE | LEE | | P= | C | 4082182 |
MARATHON PLUMBING & HEATING INC. | P= | P | 12/03/2010 | two lavs incomplete, secure rear sillcock to wall, install strainer in floor sink, protect drain down threads on irrigation, need potable h20 report | LEE | LEE | | P= | P | 4080131 |
MARATHON PLUMBING & HEATING INC. | PTO | C | 07/29/2010 | 3" C/O IN BEDROOM CLOSET, NEED AAV AT BAR SINK | LEE | LEE | | PTO | C | 4016712 |
MARATHON PLUMBING & HEATING INC. | PWO | C | 05/06/2010 | | LEE | LEE | | PWO | C | 3977284 |
MARATHON PLUMBING & HEATING INC. | PB | C | 03/22/2010 | WATER SERVICE THRU WALL AT LATER DATE | LEE | LEE | | PB | C | 3956570 |
MARATHON PLUMBING & HEATING INC. | PB | P | 03/19/2010 | LOST TEST, UNCOVER PIPE AND FITTINGS AS MUCH AS YOU CAN E/W SIDES, NO WATER SERVICE | LEE | LEE | | PB | P | 3956179 |