KDK'S MANUFACTURED HOME SERVICE INC. | B= | C | 12/21/2010 | Coloardo state insignia affixed to house this date. | LEEG | LEEG | | B= | C | 4088446 |
KDK'S MANUFACTURED HOME SERVICE INC. | B= | T | 12/16/2010 | PAID (REC#951722) Smoke detectors in house do not operate / no address or space numbers on house. These items are from previous inspections and have not been completed. | LEEG | LEEG | | B= | T | 4086580 |
KDK'S MANUFACTURED HOME SERVICE INC. | B= | R | 12/14/2010 | House locked, no entry to test smoke detectors / no access to permit card / missing space numbers on house. Trip fee waived 12/16/10 by inspector. | LEEG | LEEG | | B= | R | 4085038 |
KDK'S MANUFACTURED HOME SERVICE INC. | B= | T | 12/01/2010 | PAID (REC#950641) Smoke detector not operable / front porch and stairs - guard rail not 36" high, handrail not gripable, risers vary over 3/8", need landing 36" in direction of travel, cut off bush is trip hazzard / no rear exit landing of stairs. | LEEG | LEEG | | B= | T | 4078516 |
KDK'S MANUFACTURED HOME SERVICE INC. | B= | R | 11/29/2010 | Additional Inspections Required: Electrical Final Inspection is not Completed yet. No inspection. Need all other required inspections scheduled and completed. | LEEG | LEEG | | B= | R | 4077383 |
KDK'S MANUFACTURED HOME SERVICE INC. | B= | T | 11/08/2010 | PAID (REC#944880) Additional Inspections Required: Electrical Final Inspection is not Completed yet, Mechanical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. Locked. No address numnbers / no porch at rear door / backfill all trenches / front porch stair treads vary over 3/8" and no gripable handrail. Could not enter home to sign permit or test smoke detector. | LEEG | LEEG | | B= | T | 4068105 |
KDK'S MANUFACTURED HOME SERVICE INC. | BTD | C | 11/01/2010 | | LEEG | LEEG | | BTD | C | 4064829 |
KDK'S MANUFACTURED HOME SERVICE INC. | BTD | R | 10/26/2010 | Approved plan requires four (4) vector braces to be equally spced, not three (3) braces. Serial number from I.D. sheet inside home is 4521-1257-G. | LEEG | LEEG | | BTD | R | 4061604 |
KDK'S MANUFACTURED HOME SERVICE INC. | BFR | T | 10/22/2010 | PAID (REC#941401) No plans, No permit, No inspection., | LEEG | LEEG | | BFR | T | 4060109 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 11/09/2010 | | TIMA | TIMA | | E= | C | 4078230 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | R | 11/03/2010 | bath gfci not working properly.bury sub panel feeder | TIMA | TIMA | | E= | R | 4078229 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | R | 10/27/2010 | NEED POWER ON | TIMA | TIMA | | E= | R | 4078228 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ES | C | 10/27/2010 | Mobile Home Meter Set: 100 AMP 3/W NEED METER SET | TIMA | TIMA | | ES | C | 4078227 |
KDK'S MANUFACTURED HOME SERVICE INC. | HO= | C | 11/24/2010 | manufactured home. | DICK | DICK | | HO= | C | 4076477 |
KDK'S MANUFACTURED HOME SERVICE INC. | HO= | T | 11/18/2010 | PAID (REC#947468) NOTHING CHANGED WITH WATER HEATER. T&P DRAIN MUST DRAIN TO OUTSIDE OF SKIRTING THROUGH AN INDIRECT WASTE. FLOOR IS STILL SAGGING. VENT IS NOT CORRECT. | DICK | DICK | | HO= | T | 4073328 |
KDK'S MANUFACTURED HOME SERVICE INC. | HO= | R | 11/12/2010 | waived trip fee, dryer only item corrected. see notes from 11/1/10 for water heater. | DICK | DICK | | HO= | R | 4070426 |
KDK'S MANUFACTURED HOME SERVICE INC. | HC | C | 11/01/2010 | RELEASE METER | MICK | MICK | | HC | C | 4064565 |
KDK'S MANUFACTURED HOME SERVICE INC. | HO= | R | 11/01/2010 | WATERHEATER T&P CONNECTION MUST TERMINATE OUTSIDE SKIRTING BUT CANNOT BE DIRECT CONNECTED. VENT MUST BE CONNECTED TO DRAFT DIVERTER. FLOOR UNDER WATERHEATER IS ROTTED AND SAGGING WITH SHIMS COVERING COMBUSTION AIR OPENING. DRYER VENT MUST TERMINATE OUTSIDE SKIRTING. PRESSURE TEST OK, METER RELEASED. | MICK | MICK | | HO= | R | 4064561 |
KDK'S MANUFACTURED HOME SERVICE INC. | HO= | P | 10/26/2010 | OPEN WATERHEATER CLOSET FOR INSPECTION. T&P TERMINATION CANNOT BE DIRECTLY CONNECTED TO OUTDOORS. EXTEND DRYER VENT TERMINATION OUTSIDE SKIRTING. TEST TO 10# FROM STUB TO METER. IF GAS FLEX CONNECTOR IS TO BE USED IT MUST BE NEW. | MICK | MICK | | HO= | P | 4061669 |
KDK'S MANUFACTURED HOME SERVICE INC. | PO= | C | 11/24/2010 | manufactured home | DICK | DICK | | PO= | C | 4076464 |
KDK'S MANUFACTURED HOME SERVICE INC. | PO= | T | 11/18/2010 | PAID (REC#947469) STILL NEED ACCESS TO INSPECT PLUMBING UNDER HOUSE. | DICK | DICK | | PO= | T | 4073333 |
KDK'S MANUFACTURED HOME SERVICE INC. | PO= | T | 11/12/2010 | PAID (REC#946244) no water to system. no test on sewer, need access to inspect lines under home. | DICK | DICK | | PO= | T | 4070405 |