BUILTRITE BUILDERS | B= | C | 07/31/2012 | | CHRISM | CHRISM | | B= | C | 4352398 |
BUILTRITE BUILDERS | B= | R | 07/30/2012 | firerock garage wall to front of porch, handrails at front and deck stairs | CHRISM | CHRISM | | B= | R | 4351033 |
BUILTRITE BUILDERS | BIN | C | 04/24/2012 | | JIMA | JIMA | | BIN | C | 4300839 |
BUILTRITE BUILDERS | BFR | C | 04/24/2012 | | JIMA | JIMA | | BFR | C | 4300838 |
BUILTRITE BUILDERS | BLA | C | 04/24/2012 | | JIMA | JIMA | | BLA | C | 4300837 |
BUILTRITE BUILDERS | BFR | P | 04/18/2012 | ok to insulate after hrr, fha strap gas pipe notch, nail off hanger at srair hole | CHRISM | CHRISM | | BFR | P | 4298764 |
BUILTRITE BUILDERS | BSP | P | 04/18/2012 | deck framing ok | CHRISM | CHRISM | | BSP | P | 4298763 |
BUILTRITE BUILDERS | BSP | P | 02/01/2012 | deck piers ok, deck post connections ok | CHRISM | CHRISM | | BSP | P | 4266585 |
BUILTRITE BUILDERS | BTR | C | 01/31/2012 | | CHRISM | CHRISM | | BTR | C | 4266072 |
BUILTRITE BUILDERS | BSP | P | 01/31/2012 | front and rear porch roofs ok | CHRISM | CHRISM | | BSP | P | 4266071 |
BUILTRITE BUILDERS | BSP | P | 11/10/2011 | rear porch frame ok / front porch lid ok, no posts | DALE | DALE | | BSP | P | 4234273 |
BUILTRITE BUILDERS | BSP | P | 11/10/2011 | structual soffitt ok | DALE | DALE | | BSP | P | 4234272 |
BUILTRITE BUILDERS | BFI | C | 06/22/2011 | r7.5 installed -- 36" depth | JIMA | JIMA | | BFI | C | 4167382 |
BUILTRITE BUILDERS | BFI | R | 06/21/2011 | need res. check on site for walkout insulation insp. / DO NOT BACK FILL INSIDE Bfn | JIMA | JIMA | | BFI | R | 4166595 |
BUILTRITE BUILDERS | BFD | C | 06/21/2011 | soils on file / drain usable / | JIMA | JIMA | | BFD | C | 4166590 |
BUILTRITE BUILDERS | BFN | C | 06/15/2011 | design on file, soils at drain | CHRISM | CHRISM | | BFN | C | 4164427 |
BUILTRITE BUILDERS | BFN | R | 06/15/2011 | need to follow 2A detail at step down walls | CHRISM | CHRISM | | BFN | R | 4164313 |
BUILTRITE BUILDERS | BFT | C | 06/13/2011 | 2800# bearing, all pads ok but two at cut | CHRISM | CHRISM | | BFT | C | 4162792 |
POSITIVE ELECTRIC, LLC | E= | C | 07/25/2012 | a/c installed | MATTHEW | MATTHEW | | E= | C | 4348823 |
POSITIVE ELECTRIC, LLC | ER | C | 04/17/2012 | finished basement, 2-20 at service, 1-20 at sub-panel, sub-panel ok | MATTHEW | MATTHEW | | ER | C | 4297942 |
POSITIVE ELECTRIC, LLC | ES | C | 04/17/2012 | Residential Underground: 200 amp 3/w; no action needed | MATTHEW | MATTHEW | | ES | C | 4297939 |
POSITIVE ELECTRIC, LLC | EUG | C | 08/09/2011 | 250 al service lateral ok | MATTHEW | MATTHEW | | EUG | C | 4190578 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/25/2012 | CORRECTIONS MADE | ROBERTV | ROBERTV | | H= | C | 4348628 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/20/2012 | NO COMBUSTION AIR SOURCE FOR W/H IN MECH ROOM, NEED TO SEE FINISHED OUTDOOR BBQ TO CHECK CLEARANCES AND ACCESSIBLE GAS SHUTOFF, REST OK. NOTE: FULL A/C FOR MAIN LEVEL SYSTEM | ROBERTV | ROBERTV | | H= | P | 4345780 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/18/2012 | RELEASE METER | ROBERTV | ROBERTV | | HC | C | 4298758 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/18/2012 | CORRECTIONS MADE | ROBERTV | ROBERTV | | HRR | C | 4298757 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/17/2012 | SEAL ELECTRIC AND PLUMBING PENETRATIONS IN BASEMENT RETURN CAVITIES, FRAME AROUND RETURN DROP IN THEATER ROOM, COULD NOT FIND OSA TO BASEMENT HVAC SYSTEM (REQUIRED FOR THEATER ROOM), REST OK. NOTE: OSA AND A/C ROUGH TO MAIN LEVEL SYSTEM, FINISHED BASEMENT | ROBERTV | ROBERTV | | HRR | P | 4297770 |
UNIQUE RADIANT HTG. & PLBG. | HI | C | 04/16/2012 | 10# TEST AND SIZING OK, (1 1/2 MAIN) 2-FURNACES, 1-W/H, 4-FIREPLACES, 1-BBQ, 1-COOKTOP | ROBERTV | ROBERTV | | HI | C | 4297290 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H16 | C | 02/16/2012 | consultation on furnace vent termination for both 90% furnaces | TED | TED | | H16 | C | 4272390 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 07/27/2012 | | LEE | LEE | | P= | C | 4350191 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 04/16/2012 | | LEE | LEE | | PTO | C | 4297128 |
UNIQUE RADIANT HTG. & PLBG. | PTO | P | 04/13/2012 | COLD WATER UNDERSIZED TOWARDS MASTER BATH, NEED TO COMPLETE NAIL PROTECTION THRU-OUT | LEE | LEE | | PTO | P | 4296441 |
UNIQUE RADIANT HTG. & PLBG. | PWO | C | 01/27/2012 | | LEE | LEE | | PWO | C | 4265066 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 06/28/2011 | no h2o under slab | TIM | TIM | | PB | C | 4170518 |