CORPORATE RIDGE OFFICE LLC | H01 | C | 06/14/2024 | ANNUAL 6/23 -- OTIS W/ PEAK SERVICE -- / 2ND FLOOR HOISTWAY DOOR INTERLOCK COVER IS MISSING. LIGHTING IN CAB HAS MULTIPLE LIGHTS OUT. WAS ABLE TO ESTABLISH TWO WAY COMMUNICATION BUT SPEAKER HAD SO MUCH STATIC IT WAS HARD TO HEAR THE OPERATOR. RBD NOTE: REQUIRED ANNUAL HYDRAULIC CATEGORY 1 TEST DUE BY THE END OF THE MONTH. (Receipt #2075177) | DUSTINS | DUSTINS | | H01 | C | 8118624 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 12/20/2023 | HO2 -- ANNUAL 6/23 -- TKE & SERVICE -- WAS ON-SITE TO TEST EMERGENCY PHONE IN THE ELEVATOR (Receipt #2018606) | BENH | BENH | | H02 | C | 7950765 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 06/22/2023 | ANNUAL 6/22 -- TKE & SERVICE -- / BUILDING TO KEEP MONTHLY FIREFIGHTERS’ EMERGENCY OPERATION AND QUARTERLY EMERGENCY PHONE TEST LOGS UP TO DATE / THREE LIGHTS IN CAB ARE BURNT OUT / BOTH PIT BUCKETS ARE OVERFLOWING AND OIL IS ON PIT FLOOR / CAB VANE NOT ENGAGING RESTRICTOR FLAG AT BOTTOM OF FLOOR 1 / RBD NOTE: REQUIRED ANNUAL HYDRAULIC CATEGORY 1 TESTING DUE BY THE END OF THE MONTH (Receipt #1963898) (cat 1 -- 6/23, DS) | DUSTINS | DUSTINS | | H01 | C | 7779731 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 12/16/2022 | HO2 -- WITNESSED ON 6/22 -- TKE & SERVICE | BENH | BENH | | H02 | C | 7613283 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 06/09/2022 | WITNESSED AT H01 -- TKE & SERVICE -- / CAR TOP LIGHT IS OUT (Receipt #1873502) | DUSTINS | DUSTINS | | H01 | C | 7405602 |
CORPORATE RIDGE OFFICE LLC | H06 | C | 06/09/2022 | WITNESSED HYDRO SAFETY TESTING WITH TKE | DUSTINS | DUSTINS | | H06 | C | 7405597 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 12/30/2021 | HO2 -- ANNUAL 6/21 -- TKE & SERVICE -- CHECK PREVIOUS ITEM AT NEXT INSPECTION | BENH | BENH | | H02 | C | 7225249 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 06/10/2021 | ANNUAL 6/2021 -- TKE & SERVICE -- / COP LOOSE (Receipt #1779890) | RANDYB | RANDYB | | H01 | C | 6997329 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 12/31/2020 | H02 -- ANNUAL 6/2020 -- TKE | RANDYB | RANDYB | | H02 | C | 6823502 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 06/23/2020 | RP 06/20--TKE--(NOTE:ALL ITEMS FROM PREVIOUS INSPECTION ADDRESSED) (Receipt #1690365) | CALE | CALE | | H01 | C | 6613747 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 12/31/2019 | H02 -- RP -- 6/19 -- TKE. CHECK PREVIOUS LISTED ITEMS AT H01 | ROBERTV | ROBERTV | | H02 | C | 6440162 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 06/13/2019 | REQUIRED ANNUAL CATEGORY 1 TESTING IS EXPIRED, LAST PERFORMED 4/2018. EMERGENCY PHONE VOICE RECORDING LISTS INCORRECT ADDRESS AS "1675 GARDEN OF THE GODS ROAD"............ 30 DAYS TO ADDRESS. PERMIT TO OPERATE WILL NOT BE ISSUED UNTIL ALL THESE ITEMS ARE REMEDIED. (Receipt #1606270)--(rp 6/19) | ROBERTV | ROBERTV | | H01 | C | 6230338 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 12/28/2018 | H02 -- RP -- 4/18 | ROBERTV | ROBERTV | | H02 | C | 6064328 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 06/27/2018 | RP - 4/18 -- TKE. ALARM BELL NOT WORKING (2ND NOTICE) (Receipt #1511101) | ROBERTV | ROBERTV | | H01 | C | 5886629 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 12/20/2017 | RP -- 4/17 -- TKE. ALARM BELL NOT WORKING | ROBERTV | ROBERTV | | H02 | C | 5718852 |
CORPORATE RIDGE OFFICE LLC | HE16 | C | 12/20/2017 | REALIGNED INSPECTIONS | ROBERTV | ROBERTV | | HE16 | C | 5718843 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 06/05/2017 | THIS VISIT SKIPPED IN LIEU OF WITNESS TEST PERFORMED 4/2017 | ROBERTV | ROBERTV | | H02 | C | 5525905 |
CORPORATE RIDGE OFFICE LLC | H06 | C | 04/07/2017 | WITNESSED 5 YEAR SAFETY TEST | ERIC | ERIC | | H06 | C | 5467908 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 12/29/2016 | RP -- 2/16 -- TKE. 5 YR WITNESS TEST NEEDS PERFORMED | ROBERTV | ROBERTV | | H01 | C | 5378732 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 06/17/2016 | RP -- 2/16 -- TKE. PIT BUCKETS ARE FULL, 5 YEAR WITNESS TEST DUE | ROBERTV | ROBERTV | | H02 | C | 5224700 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 12/14/2015 | RP -- 1/15 -- TKE (CALL ROGER FOR ACCESS 648-4401). EMERGENCY PHONE ELEVATOR # INCORRECT ON VOICE CHIP, REINSTALL HOISTWAY WIRE GUTTER COVERS. 5 YEAR WITNESS TEST DUE 1/2016 (Receipt #1304071) | ROBERTV | ROBERTV | | H01 | C | 5098331 |
CORPORATE RIDGE OFFICE LLC | H02 | C | 06/29/2015 | RP 1-15 DOVER | TOM | TOM | | H02 | C | 4983179 |
CORPORATE RIDGE OFFICE LLC | H01 | C | 12/22/2014 | RP 9-13 DOVER PRESSURE RELIEF TEST EXPIRED (SEPT-13) (Receipt #1239354) | TOM | TOM | | H01 | C | 4879597 |
SPRINGS GARDEN OF THE GODS, LLC | H02 | C | 06/19/2014 | RP 9-13-TKEPHONE IN CAR NOT WORKING--CONTACT ROGER @ FACILITIES FOR M/R ACCESS (ASK FOR HIM @ GUARD DESK AT ENTRANCE) | TOM | TOM | | H02 | C | 4767696 |
SPRINGS GARDEN OF THE GODS, LLC | H01 | C | 12/26/2013 | RP 5-13-DOVER--PHONE IN CAR NOT WORKING (Receipt #1173193) | TOM | TOM | | H01 | C | 4665170 |
SPRINGS GARDEN OF THE GODS, LLC | H02 | C | 06/14/2013 | RP 5-13 EXPIRED | TOM | TOM | | H02 | C | 4554281 |
SPRINGS GARDEN OF THE GODS, LLC | H01 | C | 12/06/2012 | RP EXP--4-11--DOVER (Receipt #1102993) | TOM | TOM | | H01 | C | 4447180 |
SPRINGS GARDEN OF THE GODS, LLC | H02 | C | 06/14/2012 | RP 4-11--TKE | TOM | TOM | | H02 | C | 4334604 |
SPRINGS GARDEN OF THE GODS, LLC | H06 | C | 03/01/2011 | WITNESSED | JOHNW | JOHNW | | H06 | C | 4225809 |