COLARELLI CONSTRUCTION, INC. | B= | C | 08/01/2012 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4352830 |
COLARELLI CONSTRUCTION, INC. | B= | P | 07/25/2012 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: rdassero@springsgov.com or 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: mmaloney@springsgov.com or 385-5080), HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet, LANDMARK PLUMBING & HTG, INC. Mechanical Final Inspection is not Completed yet. | CHRISM | CHRISM | | B= | P | 4348587 |
COLARELLI CONSTRUCTION, INC. | BFR | P | 05/16/2012 | wall framing OK pending other roughs | DANF | DANF | | BFR | P | 4311789 |
RYBA ELECTRIC, INC. | E= | C | 07/24/2012 | | CRAIG | CRAIG | | E= | C | 4347345 |
RYBA ELECTRIC, INC. | ER | P | 06/29/2012 | ceilings except conference and pt | GARYL | GARYL | | ER | P | 4334344 |
RYBA ELECTRIC, INC. | ER | P | 06/27/2012 | CEILINGS NOT INSPECTED MARKED AND DATED ON PRINTS | GARYL | GARYL | | ER | P | 4332899 |
RYBA ELECTRIC, INC. | ESL | P | 06/05/2012 | 5-boxes, 3-areas | GARYL | GARYL | | ESL | P | 4321349 |
RYBA ELECTRIC, INC. | ER | P | 05/31/2012 | hard lids only, need access installed mens room #141 | GARYL | GARYL | | ER | P | 4318983 |
RYBA ELECTRIC, INC. | ER | P | 05/17/2012 | rest of walls | MIKEC | MIKEC | | ER | P | 4312802 |
RYBA ELECTRIC, INC. | ER | P | 05/11/2012 | walls only...marked/dated on prints | GARYL | GARYL | | ER | P | 4309849 |
HVAC SOLUTIONS, INC. | H= | C | 07/26/2012 | TEST AND BALANCE REPORT RECEIVED. | NANCY | NANCY | | H= | C | 4348909 |
LANDMARK PLUMBING AND HEATING, INC. | H= | C | 07/25/2012 | GAS FINAL OK. | NANCY | NANCY | | H= | C | 4348709 |
LANDMARK PLUMBING AND HEATING, INC. | H= | P | 07/24/2012 | PLUG OPEN GAS LINE TO BBQ. | NANCY | NANCY | | H= | P | 4347700 |
HVAC SOLUTIONS, INC. | H= | P | 07/24/2012 | MECHANICAL FINAL OK PENDING RECEIPT OF TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4347694 |
HVAC SOLUTIONS, INC. | H= | P | 07/11/2012 | COMPLETE MINI-SPLIT INSTALLATION, RUN CONDENSATE DRAIN. INSTALL AND VENT RANGE HOOD. PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4339926 |
LANDMARK PLUMBING AND HEATING, INC. | HC | C | 06/27/2012 | RELEASE METER | LYNNS | LYNNS | | HC | C | 4333064 |
LANDMARK PLUMBING AND HEATING, INC. | HI | C | 06/27/2012 | 2- 10# TESTS AND SIZING OK. | LYNNS | LYNNS | | HI | C | 4333052 |
HVAC SOLUTIONS, INC. | HD | C | 06/21/2012 | ABOVE CEILING ALL OK. OK TO COVER PER MECHANICAL ONLY. FOR FINAL INSTALL 2 INCH RETAINING ANGLES AROUND SUPPLY AIR FIRE DAMPER, INSTALL MINI-SPLIT, INSTALL T-STATS, INSTALL RANGE HOOD, PROVIDE MAKE-UP AIR FOR LAUNDRY ROOM, PROPERLY TERMINATE DRYER VENT ON ROOF AND PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | HD | C | 4329910 |
HVAC SOLUTIONS, INC. | HD | R | 05/31/2012 | EF3 IN SHOWER AREA: EXHAUST DUCT RESTING ON WATER LINES, ONLY SUPPORTED BY GRID WIRE? PROPERLY SUPPORT BOTH EXHAUST DUCTS IN SHOWER AREA. EXHAUST IN MENS BATHROOM 143 OK. DRYER VENT IN WALL AND CEILING OK, STILL NEED TO SEE ROOF. SPACING AROUND FIRE DAMPERS OK, OK FOR SECOND ANGLES. CHECK INSTALLATION INSTRUCTIONS AND HAVE AVAILABLE AT NEXT INSPECTION, THIS BRAND OF DAMPER PROBABLY REQUIRES MINIMUM OF 1 INCH OF ANGLE PAST FRAMING. | NANCY | NANCY | | HD | R | 4318838 |
HVAC SOLUTIONS, INC. | HD | P | 05/23/2012 | OK TO WRAP ALL LATERALS IN BLUE ON WORKING PRINTS. REPLACE BROKEN SUPPLY ELBOW IN CEILING OF OFFICE 144. | NANCY | NANCY | | HD | P | 4315533 |
HVAC SOLUTIONS, INC. | HD | P | 05/16/2012 | FIRE DAMPER WALL FRAMING OK. INSTALL FIRE DAMPERS TO VERIFY CLEARANCES. OK TO WRAP ALL SUPPLY AIR IN GREEN ON WORKING PRINTS. | NANCY | NANCY | | HD | P | 4312087 |
HVAC SOLUTIONS, INC. | HD | P | 05/15/2012 | PROPERLY FRAME SUPPLY AIR FIRE DAMPER. OK TO WRAP ALL SUPPLY AIR IN ORANGE ON WORKING PRINTS. | NANCY | NANCY | | HD | P | 4311416 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 07/25/2012 | | LEE | LEE | | P= | C | 4348095 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 07/24/2012 | LACKS PARTITIONS ALL RESTROOMS, NEED OWNER SUPPLIED KITCHEN EQUIPMENT, INSTALL TRAP GUARDS, CRITICAL LEVELS NOT MET ON FOUR FLUSH VALVES | LEE | LEE | | P= | P | 4347146 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | C | 05/29/2012 | | JOEL | JOEL | | PTO | C | 4317715 |
LANDMARK PLUMBING AND HEATING, INC. | PTO | P | 05/25/2012 | SHOWER/MENS/AND BREAK ROOM O.K, 4'' LACKS GRADE IN BACK TO BACK RESTROOMS | JOEL | JOEL | | PTO | P | 4316761 |
LANDMARK PLUMBING AND HEATING, INC. | PB | C | 05/03/2012 | | LEE | LEE | | PB | C | 4306079 |
LANDMARK PLUMBING AND HEATING, INC. | PB | P | 05/01/2012 | LOST TEST WEST GAUGE, VENTING IN QUESTION AT DUAL 2" F/D BRANCH, NEW URINAL / LAV IN QUESTION ? (ON CARRIER PIPING ?) | LEE | LEE | | PB | P | 4304747 |