GERALD H PHIPPS INC | B= | C | 10/03/2012 | All other required Final inspections are complete. (This is a computer generated result) | BERTW | BERTW | | B= | C | 4393913 |
GERALD H PHIPPS INC | B= | P | 09/27/2012 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: rdassero@springsgov.com or 385-5982, x2), BERWICK ELECTRIC CO Electrical Final Inspection is not Completed yet, MECH ONE, INC. Mechanical Final Inspection is not Completed yet, MESA PLUMBING & HEATING INC. Mechanical Final Inspection is not Completed yet. | BERTW | BERTW | | B= | P | 4390328 |
GERALD H PHIPPS INC | BFR | C | 09/27/2012 | | BERTW | BERTW | | BFR | C | 4390315 |
GERALD H PHIPPS INC | BSP | P | 09/13/2012 | penetrations sealed above grid ok | BERTW | BERTW | | BSP | P | 4380840 |
GERALD H PHIPPS INC | BFR | P | 09/07/2012 | met with matt 499-5197- ok to rock above bathroom entry and exhaust shaft | BLAKE | BLAKE | | BFR | P | 4377766 |
MECHONE, INC. | BSP | P | 08/28/2012 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical | DALEH | DALEH | | BSP | P | 4370743 |
GERALD H PHIPPS INC | BSP | T | 08/28/2012 | PAID (REC#1075277) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: revise corridor to smoke only | SHELLEY | SHELLEY | | BSP | T | 4370701 |
GERALD H PHIPPS INC | BFR | P | 08/27/2012 | All ok. Recall for exhaust at shaft and bathroom entry at smoke portion. | ROGER | ROGER | | BFR | P | 4369847 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | BSP | T | 08/21/2012 | PAID (REC#1072672) ADDITIONAL PLAN REVIEW TIME: $50 From: SHELBY | SHELBY | SHELBY | | BSP | T | 4366551 |
MECHONE, INC. | BSP | T | 08/21/2012 | PAID (REC#1072532) PLAN SPLICE FEE: $50 by: RUSSELL for Mechanical: Divided up conference room into 2 and added 2 consult rooms | RUSSELL | RUSSELL | | BSP | T | 4366545 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 10/01/2012 | | BRET | BRET | | E= | C | 4392784 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | P | 09/26/2012 | need panel schedules ----gfci disposal outlet-----color chart panels | CRAIGS | CRAIGS | | E= | P | 4389366 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | EP | R | 09/26/2012 | | CRAIGS | CRAIGS | | EP | R | 4389365 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | E= | C | 09/26/2012 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | E= | C | 4389364 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | C | 09/26/2012 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | ER | C | 4389356 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 09/24/2012 | corridors and bath ok | BRET | BRET | | ER | P | 4387341 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | C | 09/24/2012 | corridor and bath ceilings----- | BRET | BRET | | ER | C | 4387339 |
GUARANTEE ELECTRICAL CONTRACTING, LLC | ER | P | 08/24/2012 | walls | BRET | BRET | | ER | P | 4368615 |
MECHONE, INC. | H= | C | 10/03/2012 | TEST AND BALANCE REPORT RECEIVED AND SCANNED. ENGINEER'S LETTER RECEIVED AND SCANNED. | NANCY | NANCY | | H= | C | 4393912 |
MESA PLUMBING & HEATING INC. | H= | C | 10/01/2012 | PIPING FINAL OK. | NANCY | NANCY | | H= | C | 4392237 |
MESA PLUMBING & HEATING INC. | H= | P | 09/20/2012 | HWS/HWR PIPING FROM VALVES TO VAV'S ALL OK, OK TO INSULATE. INSTALL STRAPS/SUPPORT AS NEEDED. | NANCY | NANCY | | H= | P | 4385519 |
MECHONE, INC. | H= | P | 09/20/2012 | MECHANICAL FINAL OK PENDING RECEIPT OF TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4385518 |
MECHONE, INC. | HD | C | 09/18/2012 | FUNCTION OF ALL FIRE/SMOKE DAMPERS OK. FOR FINAL INSTALL 12X12 ACCESS DOOR FOR EXHAUST FIRE/SMOKE DAMPER. LABEL ALL ACCESS DOORS AND GRID. COMPLETE INSTALLATION OF GRILLS. CHECK SMOKE DETECTORS IN DUCTS. PROVIDE TEST AND BALANCE REPORT. BATHROOMS OK, OK FOR TILE PER MECHANICAL ONLY. | NANCY | NANCY | | HD | C | 4383524 |
MECHONE, INC. | HD | P | 09/10/2012 | FOUR FIRE DAMPERS IN CORRIDOR: SPACE AROUND DAMPERS OK, OK TO INSTALL ANGLES. MEDIUM PRESSURE SUPPLY AIR IN MAIN CORRIDOR: OK TO WRAP ALL. | NANCY | NANCY | | HD | P | 4378160 |
MECHONE, INC. | HD | P | 09/05/2012 | MAIN CORRIDOR RETURN AIR: OK TO WRAP. | NANCY | NANCY | | HD | P | 4375522 |
MESA PLUMBING & HEATING INC. | HWP | C | 09/04/2012 | 50 LB TEST OK ON HWS/HWR, ENTIRE SYSTEM EXCEPT LAST SECTIONS FROM SHUT OFFS TO VAV'S. OK TO INSULATE. FOR FINAL INSTALL PIPING TO VAV'S. | NANCY | NANCY | | HWP | C | 4374704 |
MECHONE, INC. | HD | P | 08/30/2012 | FOUR FIRE/SMOKE DAMPER FRAMES OK, OK TO INSTALL DAMPERS. OK TO INSULATE RETURN AIR DUCT ABOVE BATHROOM LOBBY. NOTE: PRINTS REVISED TO SHOW CORRIDOR WALLS ARE NOW SMOKE WALLS, NOT 1 HOUR WALLS. | NANCY | NANCY | | HD | P | 4372433 |
MECHONE, INC. | HD | P | 08/22/2012 | PROPERLY FRAME FOUR FIRE/SMOKE DAMPERS IN CORRIDOR WALLS. | NANCY | NANCY | | HD | P | 4366725 |
MESA PLUMBING & HEATING INC. | P= | C | 09/24/2012 | | LYNNIE | LYNNIE | | P= | C | 4387351 |
MESA PLUMBING & HEATING INC. | P= | R | 09/21/2012 | CANCELED AT DOCK | LYNNIE | LYNNIE | | P= | R | 4386463 |
MESA PLUMBING & HEATING INC. | PTO | C | 09/12/2012 | | LYNNIE | LYNNIE | | PTO | C | 4379970 |
MESA PLUMBING & HEATING INC. | PTO | P | 08/24/2012 | POC IS GARY AT 661-9769====LACKS DOMESTIC H/C TIE INS IN HALLWAYS | LYNNIE | LYNNIE | | PTO | P | 4368746 |
MESA PLUMBING & HEATING INC. | PTO | R | 08/23/2012 | NOT READY | LYNNIE | LYNNIE | | PTO | R | 4367697 |