CREEKSTONE DEVELOPMENT, INC. | B= | C | 07/03/2013 | | JOND | JOND | | B= | C | 4556647 |
CREEKSTONE DEVELOPMENT, INC. | B= | P | 05/29/2013 | Temp CO: partial building final ( Expires: 6/28/2013 12:00:00 AM) | NELIDA | NELIDA | | B= | P | 4532017 |
CREEKSTONE DEVELOPMENT, INC. | B= | P | 05/24/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), Mechanical Final Inspection is not Completed yet. need door hardware on garage to house door / need cap on handrails / need sump pump and piped out at sump pit at outside / need fire final signed off / finished basement | JOND | JOND | | B= | P | 4530814 |
CREEKSTONE DEVELOPMENT, INC. | BLA | C | 04/11/2013 | | JOND | JOND | | BLA | C | 4504215 |
CREEKSTONE DEVELOPMENT, INC. | BFR | C | 03/29/2013 | | JOND | JOND | | BFR | C | 4496690 |
CREEKSTONE DEVELOPMENT, INC. | BIN | C | 03/29/2013 | | JOND | JOND | | BIN | C | 4496689 |
CREEKSTONE DEVELOPMENT, INC. | BIN | R | 03/27/2013 | need air barrier behind fireplace downstairs / need frame signed off | JOND | JOND | | BIN | R | 4494659 |
CREEKSTONE DEVELOPMENT, INC. | BFR | T | 03/27/2013 | PAID (REC#1119999) items not done / need to strap balloon wall upstairs / can't see post connection at deck | JOND | JOND | | BFR | T | 4494656 |
CREEKSTONE DEVELOPMENT, INC. | BFR | R | 03/21/2013 | strap balloon wall upstairs / clean out b-vent chase and firestop top of chase / shoot down t-post in garage / fireblock garage brackets / need angle bracket at ml's by stairs / can't see post connections at deck frame / ok to insulate | JOND | JOND | | BFR | R | 4491486 |
CREEKSTONE DEVELOPMENT, INC. | BTR | C | 03/04/2013 | | JOND | JOND | | BTR | C | 4480820 |
CREEKSTONE DEVELOPMENT, INC. | BTR | R | 02/28/2013 | need to daylight sidewall flashings / need jack on a 3" pipe at south backside of house | JOND | JOND | | BTR | R | 4479213 |
CREEKSTONE DEVELOPMENT, INC. | BSP | P | 02/07/2013 | deck piers OK | JIMP | JIMP | | BSP | P | 4468091 |
CREEKSTONE DEVELOPMENT, INC. | BSP | R | 01/09/2013 | need plans that show location of piers | JIMP | JIMP | | BSP | R | 4451602 |
CREEKSTONE DEVELOPMENT, INC. | BFN | C | 10/31/2012 | picked up engineers inspection report | TERRYB | TERRYB | | BFN | C | 4412926 |
CREEKSTONE DEVELOPMENT, INC. | BFT | C | 10/31/2012 | picked up engineers inspection report | TERRYB | TERRYB | | BFT | C | 4412924 |
CREEKSTONE DEVELOPMENT, INC. | BFD | C | 10/31/2012 | 2 daylight pipes at back of house | TERRYB | TERRYB | | BFD | C | 4412920 |
CREEKSTONE DEVELOPMENT, INC. | BFN | P | 10/31/2012 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4412546 |
CREEKSTONE DEVELOPMENT, INC. | BFT | P | 10/31/2012 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4412545 |
SANCHEZ ELECTRIC, INC. | E= | C | 05/16/2013 | CONTRACTOR SENT PICTURE OF ACCESS | MIKEC | MIKEC | | E= | C | 4525275 |
SANCHEZ ELECTRIC, INC. | E= | P | 05/15/2013 | NEED TO SEE WHIRLPOOL ACCESS, TUB NOT SET YET. 40 AMP A.C | MIKEC | MIKEC | | E= | P | 4524515 |
SOUTHERN COLORADO ELECTRIC INC. | ER | C | 03/13/2013 | NO MULTI WIRE #8CU----FINISHED BASEMENT---- | TIMA | TIMA | | ER | C | 4486273 |
SOUTHERN COLORADO ELECTRIC INC. | ER | R | 03/12/2013 | STILL NEED TO SEAL THE AIR RETURN HOLES IN LIVING ROOM,STILL NEED TO RE-IDENTIFY TRAVELERS , INSTALL PLATES ON FIREPLACE OUTLETS | TIMA | TIMA | | ER | R | 4485362 |
SOUTHERN COLORADO ELECTRIC INC. | ES | C | 03/07/2013 | Residential Underground: 200 AMP 3/W NEW RES. | TIMA | TIMA | | ES | C | 4482892 |
SOUTHERN COLORADO ELECTRIC INC. | ER | R | 03/07/2013 | NEED UFER GROUND,SEAL AIR RETURN LIVING ROOM,NEED OUTLETS ON ALL 3' WALLS IN FOYER,RE-IDENTIFY WHITE TRAVELERS,WIRE FIREPLACE ,BOND TUB AND TUB HEATER TOGETHER | TIMA | TIMA | | ER | R | 4482877 |
SPRINGS CUSTOM PLUMBING, INC. | H= | C | 05/29/2013 | | LEE | LEE | | H= | C | 4531944 |
SPRINGS CUSTOM PLUMBING, INC. | H= | P | 05/20/2013 | CANT SCREW COPPER TO GALVANIZE ON BOILER CONNECTIONS -- TERMINATE BOILER T&P ON THE VERTICAL | LEE | LEE | | H= | P | 4527306 |
BRUNO'S HEATING & COOLING | H= | C | 05/17/2013 | Corrections made and leakage report received. | MICHAELS | MICHAELS | | H= | C | 4525956 |
BRUNO'S HEATING & COOLING | H= | R | 05/14/2013 | Install b-vent cap, install concentric cap, seal lineset on outside, need duct leakage report. | MICHAELS | MICHAELS | | H= | R | 4523300 |
SPRINGS CUSTOM PLUMBING, INC. | H= | P | 04/12/2013 | Boiler ok. Need doors in place and duct leakage report. | MICHAELS | MICHAELS | | H= | P | 4505023 |
BRUNO'S HEATING & COOLING | HC | C | 03/19/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4490165 |
BRUNO'S HEATING & COOLING | HRR | C | 03/19/2013 | Heat calcs and rough ok. Note: 4" b-vent is at max capacity for boiler, FB, NO osa, a/c rough(coil and lineset), direct vent furnace. BY FINAL: duct leakage report for attic. | MICHAELS | MICHAELS | | HRR | C | 4490164 |
SPRINGS CUSTOM PLUMBING, INC. | HWP | C | 03/13/2013 | 55# test ok. Main and upper levels. | MICHAELS | MICHAELS | | HWP | C | 4486611 |
PLATINUM PLUMBING INC | HI | C | 02/14/2013 | 10# test ok. | MICHAELS | MICHAELS | | HI | C | 4472048 |
PLATINUM PLUMBING INC | HI | P | 02/13/2013 | Low test. 1 1/2" main to boiler, 3-fp, bbq, garage furnace. No card on site. | MICHAELS | MICHAELS | | HI | P | 4471099 |
SPRINGS CUSTOM PLUMBING, INC. | HWP | P | 11/14/2012 | 60# test ok. 4-basement zones. | MICHAELS | MICHAELS | | HWP | P | 4421852 |
SPRINGS CUSTOM PLUMBING, INC. | P= | C | 05/21/2013 | | LEE | LEE | | P= | C | 4528177 |
SPRINGS CUSTOM PLUMBING, INC. | P= | P | 05/20/2013 | SCALDING WATER AT SHOWER HEADS -- LEAK AT VESSEL SINK --- NOTES FOR RBD --- HAS PVB FOR IRRIGATION | LEE | LEE | | P= | P | 4527309 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | C | 02/22/2013 | | LEE | LEE | | PTO | C | 4476234 |
SPRINGS CUSTOM PLUMBING, INC. | PTO | P | 02/20/2013 | ANCHOR CLOSET FLANGES TO FLOOR X-2 -- 1-1/2" VENT LACKS TEST -- SUPPORT DWV WHERE APPLICABLE | LEE | LEE | | PTO | P | 4475217 |
SPRINGS CUSTOM PLUMBING, INC. | PB | C | 11/09/2012 | | LEE | LEE | | PB | C | 4420049 |
SPRINGS CUSTOM PLUMBING, INC. | PB | P | 11/08/2012 | 63 PSI TEST ON H20 SERVICE ?? DWV OK | LEE | LEE | | PB | P | 4418968 |