ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 03/08/2013 | | JIMP | JIMP | | B= | C | 4483652 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 12/26/2012 | | JOND | JOND | | BIN | C | 4445494 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | P | 12/24/2012 | need 2" clearance from fireplace flue / all other areas good | JOND | JOND | | BIN | P | 4445144 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 12/21/2012 | | JOND | JOND | | BFR | C | 4444474 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | P | 12/21/2012 | need vapor barrier behind tub upstairs and behind fireplace chase | JOND | JOND | | BIN | P | 4444473 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 12/18/2012 | clearances on wood burning fireplace ok / need to firestop at upper level | JOND | JOND | | BSP | P | 4442364 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | R | 12/18/2012 | tie off ends of laterals / laterals missing at E and G trusses / 2 h2.5's at A1 trusses / firestop throughout / missing clip at D truss / tbe's missing at BGE girder / support stair beam / nail off hanger in basement / ok to insulate | JOND | JOND | | BFR | R | 4442363 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 12/17/2012 | PLAN SPLICE: (No Fee) by: JEFFREY for Construction: splice - moved 2nd floor ext. wall to line up with lower level ext. wall | JEFFREY | JEFFREY | | BSP | P | 4441768 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 12/03/2012 | top of the stairs less than 6'8" at it's final. The stairs and landing have been change to accept the new code for rise and run which puts the head room slightly below the allowable. Pepper has approved the lower height. | JIMP | JIMP | | BSP | P | 4432834 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 10/11/2012 | | JIMP | JIMP | | BFD | C | 4399586 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 10/08/2012 | | JIMP | JIMP | | BFT | C | 4397454 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 10/08/2012 | 5% grade at final; drain habitable space; float walls and isolate pads; eufer ground installed | JIMP | JIMP | | BFN | C | 4397453 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 10/03/2012 | need full soils from engineer | JIMP | JIMP | | BFT | P | 4394558 |
SERVICE FIRST ELECTRIC | E= | C | 02/25/2013 | A/C INSTALLED--20 AMP-- | TIMA | TIMA | | E= | C | 4476574 |
SERVICE FIRST ELECTRIC | E= | R | 02/22/2013 | STRAP FLEX AT FURNACE,NEED GUARDED LIGHT FURNACE ROOM,NEED ACCESS TO GARAGE DOOR OUTLET------A/C INSTALLED 20 AMP--- | TIMA | TIMA | | E= | R | 4476063 |
SERVICE FIRST ELECTRIC | ES | C | 12/17/2012 | Residential Underground: new 200 amp service | MIKEC | MIKEC | | ES | C | 4441255 |
SERVICE FIRST ELECTRIC | ER | C | 12/17/2012 | permit blew away | MIKEC | MIKEC | | ER | C | 4441241 |
GENE'S HEATING AND AIR LLC | H= | C | 02/25/2013 | OK NOTE FINISHED BASEMENT ,A/C | DAVIDH | DAVIDH | | H= | C | 4476558 |
GENE'S HEATING AND AIR LLC | HC | C | 12/17/2012 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4441339 |
GENE'S HEATING AND AIR LLC | HRR | C | 12/17/2012 | Correction made, Note: FB, 6" osa, a/c rough(coil and lineset). AT FINAL: check pex clearance to s/w connector. | MICHAELS | MICHAELS | | HRR | C | 4441338 |
KAMPP-L ENTERPRISES, INC. | HI | C | 12/14/2012 | 10# test ok. 1" main to furn, w/h, bbq. | MICHAELS | MICHAELS | | HI | C | 4440506 |
GENE'S HEATING AND AIR LLC | HRR | T | 12/14/2012 | PAID (REC#1100967): pex lacks clearance to s/w connector on w/h, Need access issue corrected to furnace before rough can be completed. | MICHAELS | MICHAELS | | HRR | T | 4440502 |
WESTERN FIREPLACE SUPPLY, INC. | HV | P | 12/13/2012 | This is a wood burning fireplace and needs to be inspected by Building inspector. | MICHAELS | MICHAELS | | HV | P | 4439348 |
GENE'S HEATING AND AIR LLC | HRR | P | 12/13/2012 | Insulation shield is not above insulation depth, questioning furnace placement for access and removal. | MICHAELS | MICHAELS | | HRR | P | 4439345 |
KAMPP-L ENTERPRISES, INC. | P= | C | 02/14/2013 | HAS R.P.B.P OUTSIDE FOR IRRIGATION | LEE | LEE | | P= | C | 4472490 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 12/13/2012 | SPIN W/H BY FINAL | LEE | LEE | | PTO | C | 4439992 |
KAMPP-L ENTERPRISES, INC. | PB | C | 10/12/2012 | | LEE | LEE | | PB | C | 4401141 |